Industrial CablesUL Style 1015 Industrial Cable
Fixed installation for power, control and lighting in both and safe areas applications.

These cables are flexible power cords of electrical tools and equipments, agricultural machines and for sea vessels power connection in marinas and shipyards. Thanks to it’s construction it is suitable…
These cables are flexible power cords of electrical tools and equipments, agricultural machines and for sea vessels power connection in marinas and shipyards. Thanks to it’s construction it is suitable for cold storage applications and heating installations if there is no risk of contact with hot parts. Polyurethane outer sheath is robust and flexbile that is resistant to medium mechanical stress, tear, abrasion and as well to oil, wet environments and UV too.
| Rated voltage | 450/750 V (U0/U) |
|---|---|
| Conductor | Electrolytic annealed, class 5 stranded plain copper wires (tinned conductor on request) |
| Insulation | EI6 type cross-linked elastomeric compound, EPR (EN 50363-1) |
| Outer sheath | Thermoplastic polyurethane of type TMPU (EN 50363-10-2) |
| Operating temperature — in flexing use | -40°C to +90°C |
| Operating temperature — in fixed use | -50°C to +90°C |
| Separator | A suitable tape may be applied over the conductor |
| Color | Orange (other colors available on request) |
| AC test voltage | 2,5 kV |
| Conductor short-circuit temp. | 250°C (Max. 5 sec) |
| Min. installation temp. | -40°C |
| Min. bending radius | EN 50565-1 Tab. 3 |
| Current carrying capacities | VDE 0298-4 Tab.13; IEC 60364-5-52 Tab. B.52.12 & Tab. C.52.1 |
| Cross Section (mm²) | Nominal Overall Diameter (mm) | Approximate Weight (kg / km) | Min.Bending Radius (free movement) (mm) | Max. Resistance of Conductors at 20°C (ohm / km) |
|---|---|---|---|---|
| 2×1 | 7,60 | 66 | 30 | 19,50 |
| 2×1,5 | 8,30 | 82 | 33 | 13,30 |
| 2×6 | 12,20 | 215 | 40 | 3,30 |
| 2×10 | 17,00 | 399 | 32 | 1,91 |
| 2×16 | 18,60 | 532 | 23 | 1,21 |
| 3×1 | 8,10 | 80 | 32 | 19,50 |
| 3×1,5 | 8,70 | 97 | 35 | 13,30 |
| 3×2,5 | 10,00 | 139 | 40 | 7,98 |
| 3×4 | 11,70 | 203 | 47 | 4,95 |
| 3×6 | 13,20 | 276 | 44 | 3,30 |
| 3×10 | 18,30 | 504 | 35 | 1,91 |
| 3×16 | 20,10 | 688 | 24 | 1,21 |
| 4×1 | 9,10 | 102 | 36 | 19,50 |
| 4×1,5 | 9,80 | 124 | 39 | 13,30 |
| 4×2,5 | 11,20 | 178 | 45 | 7,98 |
| 4×4 | 13,10 | 260 | 65 | 4,95 |
| 4×6 | 14,70 | 353 | 49 | 3,30 |
| 4×10 | 20,20 | 636 | 39 | 1,91 |
| 4×16 | 22,10 | 869 | 27 | 1,21 |
| 5×1 | 10,10 | 122 | 40 | 19,50 |
| 5×1,5 | 11,00 | 149 | 44 | 13,30 |
| 5×2,5 | 12,40 | 215 | 99 | 7,98 |
| 5×4 | 14,50 | 315 | 72 | 4,95 |
| 5×6 | 16,30 | 430 | 54 | 3,30 |
| 5×10 | 22,30 | 769 | 43 | 1,91 |
| 5×16 | 24,60 | 1064 | 30 | 1,21 |
Tell us your quantity and requirements — we reply within one business day.
Industrial CablesFixed installation for power, control and lighting in both and safe areas applications.
Industrial Cables3GKW MM Flex Industrial Cable for industrial applications. Construction: Tinned fine copper strands (class 5 acc. to IEC 60228); Cross-linked elastomeric special compound; Cross-linked elastomeric special compound.
Industrial Cables3GKW M Industrial Cable for industrial applications. Construction: Electrolytic tinned, class 5 stranded copper wires (Iec 60228); Halogen‐free. heat resistant. cross‐linked elastomeric special compound (Requirements based on type El 109…
Share your specifications and quantities. Our team will review your request and come back with sourcing options and a quotation.