Mining CablesAS/NZS 2802 Type 455 Mining Cable
General use cable for mines (except for underground coal mines). Suitable to trailing and reeling due to its’ smaller dimensions.

General use cable for mines (except for underground coal mines). Suitable to use as a trailing cable. Smaller cables
General use cable for mines (except for underground coal mines). Suitable to use as a trailing cable. Smaller cables
used for drills and handheld equipment. Large cables used to supply bigger machines.
| Rated voltage | 1.1/1.1 kV, 3.3/3.3 kV, 6.6/6.6 kV, 11/11 kV, 22/22 kV |
|---|---|
| Conductor | Electrolytic, multiple-stranded circular flexible tinned copper wire (rope lay) AS/NZS 1125-2.10 |
| Insulation | R-EP-90 (Class 2, acc. to AS/NZS 3808) |
| Outer sheath | Heavy-duty elastomer outer sheath (acc.to AS/NZS 3808) |
| Separator | Semiconducting layer over power cores in 3.3/3.3kV and above types |
| Separator | Semiconducting layer (3.3/3.3kV and above) |
| Screen | Tinned copper / Nylon braided screen over phase cores. |
| Layup | Cores are laid up over a semiconducting cradle with one pilot core in the center and without contacting each other. |
| Related standards | AS/NZS 2802 |
| Test voltage | 4,2 kV, 12 kV, 22 kV, 30 kV 45 kV |
| Power Cores | Core screen | Pilot core | Sheath | Mass | ||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| CROSS SECTION (mm2) | Strand no/mm | Conductor Diameter Nom. mm | Insulation thickness mm | Insulation diameter Nom. mm | Braid wires no/mm | Crosssection mm2 | Strand Min.no/mm | Insulation thickness Min.mm | Thickness mm | Overall diameter Nom. Mm | APPX. WEIGHT (kg / km) | COPPER WEIGHT (kg / km) |
| TYPE | 409.1 | 1.1/1.1 kV | Class 2 | insulation | ||||||||
| 16 | 126/0.40 | 5.7 | 1.6 | 9 | 7/0.25 | 9.6 | 24/0.20 | 0.8 | 4 | 35.8 | 200 | 745 |
| 25 | 209/0.40 | 7.2 | 1.6 | 10.5 | 7/0.25 | 11.3 | 24/0.20 | 0.8 | 4.3 | 39.7 | 260 | 1.053 |
| 35 | 285/0.40 | 8.5 | 1.6 | 11.8 | 7/0.25 | 12.4 | 24/0.20 | 0.8 | 4.6 | 43.1 | 310 | 1.373 |
| 50 | 380/0.40 | 10 | 1.7 | 13.5 | 7/0.25 | 14.1 | 40/0.20 | 0.8 | 5 | 47.7 | 385 | 1.859 |
| 70 | 203/0.67 | 12 | 1.8 | 16 | 7/0.25 | 16.5 | 40/0.20 | 0.8 | 5.4 | 53.9 | 510 | 2.504 |
| 95 | 259/0.67 | 13.2 | 2 | 17.6 | 7/0.30 | 21.8 | 40/0.20 | 0.8 | 6 | 59.3 | 630 | 3.376 |
| 120 | 336/0.67 | 15.3 | 2.1 | 20 | 7/0.30 | 24.7 | 40/0.20 | 0.8 | 6.4 | 65.1 | 770 | 4.18 |
| 150 | 427/0.67 | 17.1 | 2.3 | 22.2 | 7/0.40 | 36.1 | 40/0.20 | 0.8 | 6.9 | 72.1 | 975 | 5.372 |
| 185 | 518/0.67 | 19.2 | 2.5 | 24.7 | 7/0.40 | 40.5 | 40/0.20 | 0.8 | 7.4 | 78.6 | 1.16 | 6.507 |
| 240 | 672/0.67 | 21.8 | 2.8 | 27.9 | 7/0.50 | 57.7 | 40/0.20 | 0.8 | 8.2 | 88.6 | 1.49 | 8.586 |
| 300 | 854/0.67 | 24.4 | 3 | 30.9 | 7/0.50 | 63.2 | 40/0.20 | 0.8 | 8.8 | 96.3 | 1.8 | 10.473 |
| TYPE | 409.3 | 3.3/3.3 kV | Class 2 | insulation | ||||||||
| 16 | 126/0.40 | 5.7 | 3 | 12.5 | 7/0.25 | 13.1 | 24/0.20 | 0.8 | 5.3 | 46.2 | 300 | 846 |
| 25 | 209/0.40 | 7.2 | 3 | 14 | 7/0.25 | 14.8 | 24/0.20 | 0.8 | 5.6 | 50.1 | 370 | 1.154 |
| 35 | 285/0.40 | 8.5 | 3 | 15.3 | 7/0.25 | 15.8 | 24/0.20 | 0.8 | 5.9 | 53.5 | 430 | 1.471 |
| 50 | 380/0.40 | 10 | 3 | 16.8 | 7/0.25 | 17.2 | 40/0.20 | 0.8 | 6.3 | 57.6 | 510 | 1.948 |
| 70 | 203/0.67 | 12 | 3 | 18.8 | 7/0.25 | 18.6 | 40/0.20 | 0.8 | 6.6 | 62.5 | 625 | 2.564 |
| 95 | 259/0.67 | 13.2 | 3 | 20 | 7/0.25 | 20.3 | 40/0.20 | 0.8 | 7.1 | 66.2 | 725 | 3.333 |
| 120 | 336/0.67 | 15.3 | 3 | 22.1 | 7/0.30 | 27.2 | 40/0.20 | 0.8 | 7.4 | 72 | 880 | 4.252 |
| 150 | 427/0.67 | 17.1 | 3 | 23.9 | 7/0.40 | 39.6 | 40/0.20 | 0.8 | 7.8 | 78 | 1.08 | 5.473 |
| 185 | 518/0.67 | 19.2 | 3 | 26 | 7/0.40 | 42.2 | 40/0.20 | 0.8 | 8.2 | 83.4 | 1.25 | 6.556 |
| 240 | 672/0.67 | 21.8 | 3 | 28.6 | 7/0.40 | 46.6 | 40/0.20 | 0.8 | 8.8 | 90.3 | 1.5 | 8.267 |
| 300 | 854/0.67 | 24.4 | 3 | 31.2 | 7/0.50 | 63.2 | 40/0.20 | 0.8 | 9.4 | 98.4 | 1.84 | 10.473 |
| TYPE | 409.6 | 6.6/6.6 kV | Class 2 | insulation | ||||||||
| 16 | 126/0.40 | 5.7 | 5 | 16.5 | 7/0.25 | 17.2 | 24/0.20 | 0.8 | 6.4 | 57.3 | 440 | 964 |
| 25 | 209/0.40 | 7.2 | 5 | 18 | 7/0.25 | 18.6 | 24/0.20 | 0.8 | 6.7 | 61.2 | 515 | 1.263 |
| 35 | 285/0.40 | 8.5 | 5 | 19.3 | 7/0.25 | 18.6 | 24/0.20 | 0.8 | 7 | 64.6 | 585 | 1.551 |
| 50 | 380/0.40 | 10 | 5 | 20.8 | 7/0.25 | 21.3 | 40/0.20 | 0.8 | 7.3 | 68.5 | 670 | 2.066 |
| 70 | 203/0.67 | 12 | 5 | 22.8 | 7/0.25 | 23.4 | 40/0.20 | 0.8 | 7.7 | 73.7 | 805 | 2.702 |
| 95 | 259/0.67 | 13.2 | 5 | 24 | 7/0.30 | 29.2 | 40/0.20 | 0.8 | 8.1 | 77.8 | 935 | 3.589 |
| 120 | 336/0.67 | 15.3 | 5 | 26.1 | 7/0.30 | 31.7 | 40/0.20 | 0.8 | 8.5 | 83.1 | 1.09 | 4.381 |
| 150 | 427/0.67 | 17.1 | 5 | 27.9 | 7/0.40 | 45.7 | 40/0.20 | 0.8 | 8.9 | 89.1 | 1.31 | 5.649 |
| 185 | 518/0.67 | 19.2 | 5 | 30 | 7/0.40 | 48.4 | 40/0.20 | 0.8 | 9.3 | 94.5 | 1.48 | 6.734 |
| 240 | 672/0.67 | 21.8 | 5 | 32.6 | 7/0.40 | 52.8 | 40/0.20 | 0.8 | 9.9 | 101.4 | 1.75 | 8.445 |
| 300 | 854/0.67 | 24.4 | 5 | 35.2 | 7/0.50 | 71.5 | 40/0.20 | 0.8 | 10.4 | 109.3 | 2.12 | 10.712 |
| TYPE | 409.11 | 11/11 kV | Class 2 | insulation | ||||||||
| 25 | 209/0.40 | 7.2 | 7.6 | 23.4 | 7/0.25 | 23.7 | 24/0.20 | 0.8 | 8.1 | 75.6 | 750 | 1.41 |
| 35 | 285/0.40 | 8.5 | 7.6 | 24.7 | 7/0.30 | 30.2 | 24/0.20 | 0.8 | 8.4 | 79.7 | 860 | 1.885 |
| 50 | 380/0.40 | 10 | 7.6 | 26.2 | 7/0.30 | 31.7 | 40/0.20 | 0.8 | 8.7 | 83.6 | 960 | 2.365 |
| 70 | 203/0.67 | 12 | 7.6 | 28.2 | 7/0.30 | 34.1 | 40/0.20 | 0.8 | 9.1 | 88.8 | 1.11 | 3.011 |
| 95 | 259/0.67 | 13.2 | 7.6 | 29.4 | 7/0.40 | 47.5 | 40/0.20 | 0.8 | 9.6 | 93.7 | 1.29 | 4.116 |
| 120 | 336/0.67 | 15.3 | 7.6 | 31.5 | 7/0.40 | 51 | 40/0.20 | 0.8 | 9.9 | 98.8 | 1.46 | 4.937 |
| 150 | 427/0.67 | 17.1 | 7.6 | 33.3 | 7/0.40 | 53.7 | 40/0.20 | 0.8 | 10.3 | 103.5 | 1.64 | 5.879 |
| 185 | 518/0.67 | 19.2 | 7.6 | 35.4 | 7/0.40 | 57.2 | 40/0.20 | 0.8 | 10.7 | 108.8 | 1.83 | 6.988 |
| TYPE | 49.22 | 22/22 kV | Class 2 | insulation | ||||||||
| 35 | 285/0.40 | 8.5 | 10.5 | 32.6 | 7/0.40 | 55.4 | 24/0.20 | 0.8 | 10 | 105 | 1.41 | 2.611 |
| 50 | 380/0.40 | 10 | 10.5 | 34.1 | 7/0.40 | 58.1 | 40/0.20 | 0.8 | 10.3 | 108.9 | 1.53 | 3.126 |
| 70 | 203/0.67 | 12 | 10.5 | 36.1 | 7/0.40 | 60.7 | 40/0.20 | 0.8 | 10.7 | 114 | 1.71 | 3.777 |
Tell us your quantity and requirements — we reply within one business day.
Mining CablesGeneral use cable for mines (except for underground coal mines). Suitable to trailing and reeling due to its’ smaller dimensions.
Mining CablesGeneral use cable for mines (except for underground coal mines). It has smaller dimensions but strong structure.
Mining CablesGeneral use cable for mines (except for underground coal mines)
Share your specifications and quantities. Our team will review your request and come back with sourcing options and a quotation.