Product Overview
EX ia intrinsically safe
ASCO LI WSLI explosion proof solenoid valve operators are ATEX certified for installation in potentially explosive atmospheres located in hazardous areas.
The solenoid operators with Intrinsically SafeIEC explosion protection techniques, are suitable for use in hazardous areas with exposure to gas, classified as Zone 0.
Hazardous Area Classification & Ex Safety Code
Ex II 1G Ex ia IIC T6 Ga
Ex II 2D Ex tb IIIC T85°C IP66/IP67 Db
EC type certificate LCIE 09 ATEX 3054 X and IECEx certificate IECEx LCI 09.0022X. IP66/IP67 ingress protection.
The Ex ia solenoid operators used in conjunction with valves are compliant with International and European Standards EN-IEC 60079-0, EN-IEC 60079-11 and EN-IEC 60079-31 and also certified for use in potentially explosive atmospheres according to ATEX-Directive 2014/34/EU.
ASco li wsli valve operators – features
- Ingress Protection Rating: IP66/IP67
- The solenoid operators have a cataphorese black painted Aluminium (LI) or 316L grade Stainless Steel (WSLI) enclosure which is provided with a cable gland for unarmoured cable with an o.d. of 6 to 12 mm
- ASCO LI & WSLI operators are easily installed with a screw terminal coil
- Peak voltage suppression is standard for DC executions
- A range of solenoid valves can be supplied with the Ex ia operators
asco ex ia valve operators – ELECTRICAL CHARACTERISTICS & Connections
Standard voltages:
- DC (=) : 24V
- Coil Insulation Class: F
- Voltage (Un) (Maximum ripple 10%): 24 Volts
- Power Ratings (Pn) – Hot/Cold = : 0.5 Watts
- Typical Functional Ratings: I (ON) Minimum – 32 mA | U (ON) Minimum – 12.5 Volts
- Temperature Rating: 20°C – 288 Ω | T6 – 354 Ω
Connections:
- Electrical connection between solenoid valve and barrier/interface with cable type A or B according to EN 50039
- Internal and external earthing connection
- The operator is able to be rotated through a full 360° to select the most favourable position for cable entry
Ex ia intrinsically safe valve operators – dimensions
TYPE LI
Prefix “LI” Solenoid
Aluminium, cataphorese black painting
Weight: 0.56 kg
IEC and EN: 60079-11, 60079-31
II 1G Ex ia IIC T6 Ga, II 2D Ex tb IIIC T85°C IP66/IP67 Db
TYPE WSLI
Prefix “WSLI” Solenoid
Stainless steel
Weight: 1.17 kg
IEC and EN: 60079-11, 60079-31
II 1G Ex ia IIC T6 Ga, II 2D Ex tb IIIC T85°C IP66/IP67 Db
asco li & wsli
This equipment must be ordered from its respective manufacturers, specifying that they are intended to feed intrinsically safe solenoid operators: LI & WSLI: II 1G Ex ia IIC T6 Ga, II 2D Ex tb IIIC T85°C IP66/IP67 Db