BS 6708 Type 307M Mining Cable

Used for supplying excavating, crushing machines and equipment.

Rated voltage1,9/3,3 kV
ConductorElectrolytic, stranded, tinned copper wire IEC 60228 Class 5
InsulationEPR (Ground core is not insulated).
Outer sheathHeavy duty chloroprene outer sheath.
  • Quoted to your quantity
  • Documentation on request
  • International delivery

Product Overview

Used for supplying excavating, crushing machines and equipment.

Technical Specifications

Rated voltage1,9/3,3 kV
ConductorElectrolytic, stranded, tinned copper wire IEC 60228 Class 5
InsulationEPR (Ground core is not insulated).
Outer sheathHeavy duty chloroprene outer sheath.
SeparatorColored Textile tape for core identification.
ScreenTinned copper / Nylon braided screen over phase and pilot cores.
LayupAll cores are laid up in contact with the bare copper earth conductor.
BeddingRubber based bedding compound.
Related standardsBS 6708
Test voltage7,5 kV
Cross Section3×25+25+253×35+25+353×50+35+503×70+50+703×95+50+953×120+70+120
Phase Conductor
Number and cross sectionmm23×253×353×503×703×953×120
Insulation diameterNom. mm13.1014.7515.8017.8019.2021.60
Screen diameterNom. mm15.5017.1018.2020.1521.6023.95
Earth Conductor
Number and cross sectionmm21×251×251×351×501×501×70
Strandingmm196/0,40196/0,40276/0,40396/0,40396/0,40360/0,50
Conductor diameterNom. mm6.756.758.209.809.8011.70
Pilot Conductor
Number and cross sectionmm21×251×351×501×701×951×120
Strandingmm196/0,40276/0,40396/0,40360/0,50475/0,50608/0,50
Conductor diameterNom. mm6.758.359.4011.3512.7515.10
Insulation diameterNom. mm13.1014.7515.8017.8019.2021.60
Screen diameterNom. mm15.5017.1018.2020.1521.6023.95
Cable details
Min. overall diametermm47.451.656.862.868.973.4
Max. overall diametermm49.954.659.865.872.777.4
Min. bending radiusmm399437478526581617
Max. pulling tensionkgf6428341.21.6822
Appx. cable weightkg/km4.256.58.19.811.6
Copper weightkg/km1.6642.0482.8663.6824.5465.65
Electrical details
“Continuous current rating at 25°C Ambient”A110135170205250295
“Intermittent current rating at 25°C Ambient”A130155210255315360
Max. DC resistance at 20°C
Phase ConductorΩ /km0.7950.5650.3930.2770.210.164
Pilot ConductorΩ /km0.7950.5650.3930.2770.210.164
4 screens and earth in parallel connectionΩ /km0.450.450.310.310.250.25
Nom. reactance at 50HzΩ /km0.1250.1170.1130.1080.1050.101
Nom. reactance at 60HzΩ /km0.150.1410.1360.1290.1260.121
Min. insulation resistance at 20°CM Ω /km12501100950820720660
3 phase voltage drop on full load currentmV/A/m1.691.210.850.610.480.39

Request Information About This Product

Tell us your quantity and requirements — we reply within one business day.

Related Products

Have a product requirement?

Share your specifications and quantities. Our team will review your request and come back with sourcing options and a quotation.