Mining CablesCables
AS/NZS 2802 Type 455 Mining Cable
General use cable for mines (except for underground coal mines). Suitable to trailing and reeling due to its’ smaller dimensions.
3.3/3.3 kV, 6.6/6.6 kV, 11/11 kV, 22/22 kV

Used as control cable in large mining machines and connecting surrounding machine segments.
Used as control cable in large mining machines and connecting surrounding machine segments.
| Rated voltage | 320/550 V |
|---|---|
| Conductor | Electrolytic, stranded, tinned copper wire IEC 60228 Class 5 |
| Insulation | EPR or TPE |
| Outer sheath | Heavy duty chloroprene outer sheath |
| Screen | Tinned copper / Nylon braided screen over cores. |
| Layup | All cores are laid up in contact with each other. |
| Bedding | Rubber based bedding compound. |
| Armour | Galvanized steel pliable armour. |
| Related standards | BS 6708 |
| Test voltage | 1,5 kV |
| Cross Section | 6×1,34 | 12×1,34 | 18×1,34 | 24×0,93 | |
|---|---|---|---|---|---|
| Conductors | |||||
| Number and cross section | mm2 | 6×1,34 | 12×1,34 | 18×1,34 | 24×0,93 |
| Insulation thickness | mm | 0.4 | 0.4 | 0.4 | 0.4 |
| Cable details | |||||
| Radial thickness of inner sheath | mm | 3.5 | 1.8 | 1.5 | 1.5 |
| Min. inner sheath diameter | mm | 14.8 | 14.8 | 16.5 | 17.9 |
| Max. inner sheath diameter | mm | 16.8 | 16.8 | 18.5 | 19.9 |
| Size of armour | mm | 7/0,45 | 7/0,45 | 7/0,45 | 7/0,45 |
| Outer sheath thickness | mm | 1.8 | 1.8 | 1.8 | 1.8 |
| Min. overall diameter | mm | 22.1 | 22.1 | 22.8 | 24.2 |
| Max. overall diameter | mm | 23.6 | 23.6 | 25.3 | 26.7 |
| Min. bending radius | mm | 236 | 236 | 253 | 267 |
| Appx. cable weight | kg/km | 1.02 | 1.2 | 1.4 | 1.6 |
| Copper weight | kg/km | 150 | 300 | 450 | 450 |
| Electrical details | |||||
| “Continuous current rating at 25°C Ambient” | A | 16 | 13 | 11 | 8 |
| Max. DC resistance at 20°C | |||||
| Conductors | Ω /km | 15.4 | 15.4 | 15.4 | 22.1 |
| Armour | Ω /km | 5.40 | 5.40 | 4.76 | 4.50 |
| 3 screens connected in parallel | Ω /km | 37.3 | 37.3 | 37.3 | 44.7 |
| DC or single phase voltage drop | mV/A/m | 34 | 34 | 34 | 50 |
| 3 phase voltage drop | mV/A/m | 30 | 30 | 30 | 43 |
Tell us your quantity and requirements — we reply within one business day.
Mining CablesGeneral use cable for mines (except for underground coal mines). Suitable to trailing and reeling due to its’ smaller dimensions.
Mining CablesGeneral use cable for mines (except for underground coal mines). It has smaller dimensions but strong structure.
Mining CablesGeneral use cable for mines (except for underground coal mines)
Share your specifications and quantities. Our team will review your request and come back with sourcing options and a quotation.