Industrial CablesUL Style 1015 Industrial Cable
Fixed installation for power, control and lighting in both and safe areas applications.

These rubber sheathed single core cables are used as Anode and DC feeder cable in cathodic protection systems for buried structures. Main areas that used are; pipelines, storage tanks, wells,…
These rubber sheathed single core cables are used as Anode and DC feeder cable in cathodic protection systems for buried structures. Main areas that used are; pipelines, storage tanks, wells, metal structures and vessels. Due to it characteristics it can bu used in wet, oily and damp places. They are resistant to chemicals, moisture, water and corrosive gases.
| Rated voltage | 600/1000 V (U0/U) |
|---|---|
| Conductor | Electrolytic annealed, class 5 stranded tinned copper wires |
| Insulation | EI4 type cross-linked elastomeric compound, EPR (EN 50363-1) |
| Sheath | EM7 type cross-linked elastomeric compound (EN 50363-2-1) |
| Operating temperature | -40°C to +90°C |
| Separator | A suitable tape may be applied over the conductor |
| Color | Black |
| AC test voltage | 4 kV |
| Conductor short-circuit temp. | 250°C (Max. 5 sec.) |
| Min. installation temp. | -25°C |
| Min. bending radius | Based on EN 50565-1 Tab. 3 |
| Current carrying capacities | VDE 0298-4 Tab.13 , IEC 60364-5-52 Tab. B.52.12 & Tab. C.52.1 |
| Cross Section (mm²) | Nominal Overall Diameter (mm) | Approximate Weight (kg / km) | Min.Bending Radius (free movement) (mm) | Max. Resistance of Conductors at 20°C (ohm / km) |
|---|---|---|---|---|
| 1×10 | 11,50 | 215 | 1,95 | 35 |
| 1×16 | 13,00 | 296 | 1,24 | 52 |
| 1×50 | 17,80 | 674 | 0,393 | 71 |
| 1×70 | 19,70 | 880 | 0,277 | 79 |
| 1×95 | 22,10 | 1130 | 0,21 | 88 |
Tell us your quantity and requirements — we reply within one business day.
Industrial CablesFixed installation for power, control and lighting in both and safe areas applications.
Industrial Cables3GKW MM Flex Industrial Cable for industrial applications. Construction: Tinned fine copper strands (class 5 acc. to IEC 60228); Cross-linked elastomeric special compound; Cross-linked elastomeric special compound.
Industrial Cables3GKW M Industrial Cable for industrial applications. Construction: Electrolytic tinned, class 5 stranded copper wires (Iec 60228); Halogen‐free. heat resistant. cross‐linked elastomeric special compound (Requirements based on type El 109…
Share your specifications and quantities. Our team will review your request and come back with sourcing options and a quotation.