Industrial CablesUL Style 1015 Industrial Cable
Fixed installation for power, control and lighting in both and safe areas applications.

They are used as installation cables in various electronic equipments and in switchboards.
They are used as installation cables in various electronic equipments and in switchboards.
They can be used on and under plaster or must be laid in pipes.
| Rated voltage | H05V-K 300/500V I H07V-K 450/750 V (U0/U) |
|---|---|
| Conductor | Electrolytic annealed, class 5 stranded plain copper wires (tinned conductor on request) |
| Insulation | PVC compound, Type TI1 (EN 50363-3) |
| WORKING TEMPERATURE (Without mechanIcal shocks) | -30°C to +70°C |
| Color | All colors available |
| AC test voltage | 2 kV |
| Conductor short-circuit temp. | 160°C (Maximum allowable time 5 sec) |
| Min. installation temp. | 5°C |
| Min. bending radius | EN 50565-1 Tab. 3 |
| Current carrying capacities | VDE 0298-4 Tab. 3 & Tab. 11 IEC 60364-5-52 Tab. B52.2 & B52.4 & B52.10 |
| Cross Section (mm²) | Nominal Overall Diameter (mm) | Approximate Weight (kg / km) | Min.Bending Radius (fixed installation) (mm) | Max. Resistance of Conductors at 20°C (ohm / km) |
|---|---|---|---|---|
| H05V-K | ||||
| 1×0,50 | 2,10 | 9 | 8 | 39,00 |
| H07V-K | ||||
| 1×1,5 | 2,90 | 19 | 12 | 13,30 |
| 1×2,5 | 3,55 | 30 | 14 | 7,98 |
| 1×4 | 4,05 | 46 | 16 | 4,95 |
| 1×6 | 4,60 | 63 | 18 | 3,30 |
| 1×10 | 6,10 | 108 | 24 | 1,91 |
| 1×16 | 7,10 | 161 | 28 | 1,21 |
| 1×25 | 9,20 | 250 | 46 | 0,780 |
| 1×35 | 10,10 | 339 | 51 | 0,554 |
| 1×50 | 12,00 | 475 | 60 | 0,386 |
| 1×70 | 13,90 | 678 | 83 | 0,272 |
| 1×95 | 15,90 | 885 | 95 | 0,206 |
| 1×120 | 17,60 | 1118 | 106 | 0,161 |
| 1×150 | 19,40 | 1390 | 116 | 0,129 |
| 1×185 | 21,70 | 1692 | 130 | 0,106 |
| 1×240 | 25,00 | 2280 | 150 | 0,0801 |
| 1×300 | 27,80 | 2819 | 167 | 0,0641 |
Tell us your quantity and requirements — we reply within one business day.
Industrial CablesFixed installation for power, control and lighting in both and safe areas applications.
Industrial Cables3GKW MM Flex Industrial Cable for industrial applications. Construction: Tinned fine copper strands (class 5 acc. to IEC 60228); Cross-linked elastomeric special compound; Cross-linked elastomeric special compound.
Industrial Cables3GKW M Industrial Cable for industrial applications. Construction: Electrolytic tinned, class 5 stranded copper wires (Iec 60228); Halogen‐free. heat resistant. cross‐linked elastomeric special compound (Requirements based on type El 109…
Share your specifications and quantities. Our team will review your request and come back with sourcing options and a quotation.