MGM 115 Type 7M Mining Cable

Used for supplying excavating, crushing machines and equipment.

Rated voltage660/1100 V
ConductorElectrolytic, stranded, tinned copper wire IEC 60228 Class 5
InsulationEPR (Ground core is not insulated)
Outer sheathHeavy duty chloroprene outer sheath.
  • Quoted to your quantity
  • Documentation on request
  • International delivery

Product Overview

Used for supplying excavating, crushing machines and equipment.

Technical Specifications

Rated voltage660/1100 V
ConductorElectrolytic, stranded, tinned copper wire IEC 60228 Class 5
InsulationEPR (Ground core is not insulated)
Outer sheathHeavy duty chloroprene outer sheath.
SeparatorColored Textile tape for core identification.
ScreenTinned copper / Nylon braided screen over phase and pilot cores.
LayupAll cores are laid up in contact with the bare copper earth conductor.
BeddingRubber based bedding compound.
Related standardsMGM 115/1985
Test voltage2,5 kV
Cross Section3×16+16+163×25+16+163×35+18+163×50+25+253×70+35+353×95+50+503×120+50+70
Phase Conductor
Number and cross sectionmm23×163×253×353×503×703×953×120
Insulation thicknessmm1.51.61.61.71.82.02.4
Earth Conductor
Number and cross sectionmm21×161×161×181×251×351×501×50
Strandingmm126/0,40126/0,40147/0,40196/0,40276/0,40396/0,40396/0,40
Conductor diameterNom. mm5.505.506.006.758.009.759.75
Pilot Conductor
Number and cross sectionmm21×161×161×161×251×351×501×70
Strandingmm126/0,40126/0,40126/0,40196/0,40276/0,40396/0,40360/0,50
Conductor diameterNom. mm5.505.505.506.758.009.7511.60
Insulation thicknessmm1.51.51.51.61.61.71.7
Cable details
Min. overall diametermm35.839.743.148.555.162.468.0
Max. overall diametermm40.644.947.353.860.868.178.0
Min. bending radiusmm366405426485548613702
Max. pulling tensionkgf4806428341.21.6822
Appx. cable weightkg/km2.42.953.524.66.27.99.65
Copper weightkg/km1.071.331.692.323.194.35.1
Electrical details
“Continuous current rating at 25°C Ambient”A85110135170205250295
“Intermittent current rating at 25°C Ambient”A96125150200250310355
Max. DC resistance at 20°C
Phase ConductorΩ /km1.240.7950.5650.3930.2770.210.164
Pilot ConductorΩ /km1.241.241.240.7950.5650.3930.277
3 screens and earth in parallel connectionΩ /km0.70.60.60.50.340.280.26
Nom. reactance at 50HzΩ /km0.1090.1070.1010.0980.0950.0940.092
Nom. reactance at 60HzΩ /km0.1310.1280.1210.1180.1140.1130.11
Min. insulation resistance at 20°CM Ω /km4353753252850.260.25250
3 phase voltage drop on full load currentmV/A/m2.621.681.20.840.610.470.38