Industrial CablesUL Style 1015 Industrial Cable
Fixed installation for power, control and lighting in both and safe areas applications.

Especially used for lifts, cranes, floor conveyor systems, elevators and festoon systems. Thanks to its flat structure, recommended for implementations where space is at a minimum and require smaller bending…
Especially used for lifts, cranes, floor conveyor systems, elevators and festoon systems. Thanks to its flat structure, recommended for implementations where space is at a minimum and require smaller bending radius over that of round cables.
| Rated voltage | 300/500 V (U0/U) |
|---|---|
| Conductor | Up to 25mm2 electrolytic anneleaed class 6 stranded copper wires, 25mm2 and above sections electrolytic anneleaed class 5 stranded copper wires. (tinned conductor on request) |
| Insulation | 3GI3 type cross-linked elastomeric compound (VDE 0207 – Part 20) |
| Outer sheath | 5GM3 type cross-linked elastomeric compound (VDE 0207 – Part 21) |
| Operating temperature — in flexing use | -25°C to +60°C |
| Operating temperature — in fixed use | -40°C to +90°C |
| Separator | A suitable tape may be applied over the conductor |
| Color | Black |
| AC test voltage | 2 kV |
| Conductor short-circuit temp. | 250°C (Max. 5 sec) |
| Min. installation temp. | -25°C |
| Min. bending radius | VDE 0298-3 Tab.3 |
| Current carrying capacities | VDE 0298-4 Tab.11 & Tab. 15 |
| Cross Section (mm²) | Nominal Overall Diameter (mm) | Approximate Weight (kg / km) | Min.Bending Radius (free movement) (mm) | Max. Resistance of Conductors at 20°C (ohm / km) |
|---|---|---|---|---|
| 3×1,5 | 6,00 x 12,30 | 126 | 18 | 13,30 |
| 3×2,5 | 7,80 x 14,40 | 181 | 23 | 7,98 |
| 3×10 | 10,60 x 27,00 | 619 | 42 | 1,91 |
| 3×16 | 12,40 x 27,00 | 797 | 62 | 1,21 |
| 3×25 | 14,00 x 36,70 | 1224 | 70 | 0,78 |
| 3×35 | 15,70 x 39,90 | 1610 | 79 | 0,554 |
| 3×50 | 18,00 x 46,20 | 2193 | 90 | 0,386 |
| 3×70 | 20,50 x 52,50 | 2998 | 103 | 0,272 |
| 3×95 | 23,30 x 60,10 | 3822 | 117 | 0,206 |
| 4×1,5 | 6,00 x 17,30 | 204 | 18 | 13,30 |
| 4×2,5 | 7,80 x 20,00 | 310 | 23 | 7,98 |
| 4×4 | 8,60 x 24,50 | 427 | 34 | 4,95 |
| 4×6 | 9,40 x 27,00 | 505 | 38 | 3,30 |
| 4×10 | 10,60 x 31,60 | 752 | 42 | 1,91 |
| 4×16 | 12,40 x 36,00 | 1018 | 62 | 1,21 |
| 4×25 | 14,00 x 45,00 | 1522 | 70 | 0,78 |
| 4×35 | 15,70 x 50,30 | 2196 | 79 | 0,554 |
| 4×50 | 18,00 x 57,50 | 2852 | 90 | 0,386 |
| 4×70 | 20,50 x 64,80 | 3872 | 103 | 0,272 |
| 4×95 | 23,30 x 74,60 | 4977 | 117 | 0,206 |
| 4×120 | 25,60 x 82,80 | 6197 | 128 | 0,161 |
| 5×1,5 | 6,00 x 21,40 | 267 | 18 | 13,30 |
| 5×2,5 | 7,80 x 24,40 | 378 | 23 | 7,98 |
| 5×4 | 8,60 x 29,50 | 505 | 34 | 4,95 |
| 5×6 | 9,40 x 34,00 | 652 | 38 | 3,30 |
| 5×10 | 10,60 x 40,50 | 904 | 42 | 1,91 |
| 5×16 | 12,40 x 47,00 | 1301 | 62 | 1,21 |
| 5×25 | 14,60 x 57,80 | 1993 | 70 | 0,78 |
| 5×35 | 15,70 x 61,30 | 2537 | 79 | 0,554 |
| 7×1,5 | 6,00 x 26,90 | 306 | 18 | 13,30 |
| 7×2,5 | 7,80 x 32,10 | 493 | 23 | 7,98 |
| 7×4 | 8,60 x 38,80 | 691 | 34 | 4,95 |
| 7×6 | 9,40 x 45,80 | 870 | 38 | 3,30 |
| 7×10 | 10,60 x 53,10 | 1239 | 42 | 1,91 |
| 7×16 | 13,00 x 65,00 | 1950 | 65 | 1,21 |
| 7×25 | 15,20 x 77,00 | 2865 | 76 | 0,78 |
| 7×35 | 16,30 x 87,10 | 3647 | 82 | 0,554 |
| 8×1,5 | 6,00 x 31,00 | 378 | 18 | 13,30 |
| 8×2,5 | 7,80 x 37,50 | 492 | 23 | 7,98 |
| 10×1,5 | 6,60 x 39,20 | 504 | 20 | 13,30 |
| 10×2,5 | 8,40 x 47,60 | 719 | 34 | 7,98 |
| 12×1,5 | 6,60 x 47,50 | 624 | 20 | 13,30 |
| 12×2,5 | 8,40 x 54,20 | 849 | 34 | 7,98 |
| 16×1,5 | 6,60 x 62,40 | 812 | 20 | 13,30 |
| 16×2,5 | 8,40 x 71,80 | 1101 | 34 | 7,98 |
| 24×1,5 | 11,90 x 54,70 | 1366 | 48 | 13,30 |
| 24×2,5 | 15,00 x 65,00 | 2116 | 60 | 7,98 |
Tell us your quantity and requirements — we reply within one business day.
Industrial CablesFixed installation for power, control and lighting in both and safe areas applications.
Industrial Cables3GKW MM Flex Industrial Cable for industrial applications. Construction: Tinned fine copper strands (class 5 acc. to IEC 60228); Cross-linked elastomeric special compound; Cross-linked elastomeric special compound.
Industrial Cables3GKW M Industrial Cable for industrial applications. Construction: Electrolytic tinned, class 5 stranded copper wires (Iec 60228); Halogen‐free. heat resistant. cross‐linked elastomeric special compound (Requirements based on type El 109…
Share your specifications and quantities. Our team will review your request and come back with sourcing options and a quotation.