VG 95218 Part 60 (MGSGO/MGGO) Defence Cable

Used as fixed installation cable in power, control and lighting electrical systems in most areas, below and above deck on Navy vessels. Comply the general requirements of BV 3400 (Specification…

ConductorElectrolytic, stranded, copper wire to DIN EN 60228; Class 2 or Class 5
InsulationHalogen free cross linked EPR compound
Outer sheathHalogen free, cross-linked elastomeric compound.
Working temperature-30°C / + 90°C
  • Quoted to your quantity
  • Documentation on request
  • International delivery

Product Overview

Used as fixed installation cable in power, control and lighting electrical systems in most areas, below and above deck on Navy vessels. Comply the general requirements of BV 3400 (Specification for Cable Systems of German Navy Vessels

Technical Specifications

ConductorElectrolytic, stranded, copper wire to DIN EN 60228; Class 2 or Class 5
InsulationHalogen free cross linked EPR compound
Outer sheathHalogen free, cross-linked elastomeric compound.
Working temperature-30°C / + 90°C
Core identificationAccording to VG 95218 part 60
Common coveringHalogen free compound. (for MGSGO types B and D)
SeparatorPolyester foil over the single core or over common covering over laid-up cores
ScreenCopper wire braiding screen with separating foil over braid (for MGSGO types A, B and D)
ConstructionVG 95218 Part 60
Max. permissible operating voltageAC 1200V / DC 1800V for type A, B, C AC 660V / DC 1000V for the type D
AC test voltage3,5 kV for type A, B, C 3 kV for type D
Min. bending radius (fixed)4xD for types with flexible conductor 5xD for all other types
General requirements and testsVG 95218-2
Current ratingsVG 95218-5
Flame retardationIEC 60332 /1, IEC 60332 / 3-24 Cat. C
Halogen contentIEC 60754 / 1 – 2
Smoke densityIEC 61034 / 1-2 ( DIN EN 50268/1-2)
Designation as per VG95218 Part.60 Dash NoCores x sizeNumber of the single wires (min)Wall thickness of insulation nominalWall thickness of sheathOuter Diameter (min- max.)Cable Weight Approx.Min. Bending Radius Fixed InstalledConductor resistance at (20ºC) (max)Insulation resistance (20ºC) (min)
No. x mm²mmmmmmmmkg/kmmm(Ω/km)(MΩ·km)
A0011 x 47117.58.5140434.7850
A0041 x 16711.11011.2290561.16500
A0051 x 2571.21.21213395650.734450
A0061 x 3571.21.21314540700.529400
A0071 x 50191.41.31516.2680810.391400
A0081 x 70191.41.31718.2910910.27350
A0091 x 95191.61.419.520.512101030.195350
A0161 x 956601.61.419.6211200840.21350
A0101 x 120371.61.52122.415001120.154300
A0171 x 1208451.61.521.8231485920.164300
A0111 x 150371.81.52324.517851230.126300
A0181 x 15010601.81.52425.218251010.132300
A0121 x 1853721.625.52722001350.1300
A0151 x 185129021.626.227.421701100.108300
A0131 x 240612.21.72930.528501530.0762300
A0191 x 24017352.21.729.53127801240.0817300
A0141 x 300612.41.831.53332501650.0607300
A0201 x 30021002.41.832.53433501360.0654300
B0342 x 1,5711.211.512.72556412.21200
B0352 x 2,5711.212.513.5305687.561000
B0362 x 4711.213.414.7355744.7850
B0372 x 6711.314.716440803.11750
B0382 x 10711.316.217.9565901.84600
B0392 x 16711.41920.57751031.16500
B0402 x 2571.21.522.52410751200.734450
B0413 x 1,5711.21213.22906612.21200
B0423 x 2,5711.21314.2350717.561000
B0433 x 4711.21415.2415764.7850
B0443 x 6711.315.517530853.11750
B0453 x 10711.417.619.1700961.84600
B0463 x 16711.42021.69801081.16500
B0653 x 1611511.42021.6965871.24500
B0473 x 2571.21.62425.614551280.734450
B0663 x 251751.21.62425.614001030.795450
B0483 x 3571.21.72628.218501410.529400
B0673 x 352501.21.726.228.418101140.565400
B0493 x 50191.41.83032.422701620.391400
B0683 x 503601.41.83133.224701330.393400
B0503 x 70191.41.934.536.932601850.27350
B0633 x 704901.41.93638.231001530.277350
B0513 x 95191.62.139.742.242002110.195350
B0623 x 956601.62.141.643.841501760.21350
B0523 x 120371.62.14345.753502290.154300
B0693 x 1208451.62.144.546.553401860.164300
B0534 x 4711.315.216.7515844.7850
B0544 x 6711.31718.5625933.11750
B0554 x 10711.419.420.98801051.84600
B0564 x 16711.52223.712351191.16500
B0704 x 1611511.52223.71165951.24500
B0574 x 2571.21.726.42818001400.734450
B0714 x 251751.21.726.428.217151130.795450
B0584 x 3571.21.829.231.223151560.529400
B0644 x 3510301.21.8313324001320.565400
B0594 x 50191.41.933.53631301800.391400
B0724 x 503601.41.934.33731551480.393400
B0604 x 70191.42.138.240.943352050.27350
B0734 x 704901.42.14042.543851700.277350
B0614 x 95191.62.344.246.755002340.195350
B0744 x 956601.62.345.548.256851930.21350
B1005 G 2,5711.31617.5460887.561000
B1015 G 4711.417.519605954.7850
B102ª7 G 2,5711.417.519585957.561000
B1037 G 2,5711.417.519585957.561000
B30ª33 X 0,7570.81.422.524.598012324.81200
B10433 x 0,7570.81.422.524.598012324.81200
C0051 x 2571.21.210.712.4355620.734450
C0061 x 3571.21.21213.7475690.529400
C0071 x 50191.21.213.214.9600750.391400
C0081 x 70191.41.315.717.4790870.27350
C0091 x 95191.61.418.219.910851000.195350
C0111 x 956601.61.418.3201095800.206350
C0101 x 120371.61.419.821.512001080.154300
C0121 x 1208451.61.520.121.81240880.161300
C0011 x 150371.81.521.52416251200.126300
C0131 x 15010601.81.521.6231640920.129300
C0021 x 185129021.624.826.319501060.106300
C0031 x 24017352.21.727.328.925101160.08300
C0041 x 30021002.41.83031.530251260.064300
D001ª19 X 6730.71.829.430.818601243.39750
D00219 x 6730.71.829.430.818601243.39750

Certifications / Standards

  • Bundeswehr (German Armed Forces)
  • VDE
  • DNV

Request Information About This Product

Tell us your quantity and requirements — we reply within one business day.

Related Products

Have a product requirement?

Share your specifications and quantities. Our team will review your request and come back with sourcing options and a quotation.