(N)3GHSSYCY Tunnelling Cable

These cables are used for the connection of mobile operating equipments, in mines and underground excavations with hazardous environments, in stationary operation, e.g.high-voltage transformers in mining and tunneling.

Rated Voltage3,6/6 kV 6/10 kV 8,7/15 kV 12/20 kV 18/30 kV
Working TemperatureAccording to DIN VDE 0298, Part 4
ColourRed or Black
AC Test Voltage11 kV 17 kV 24 kV 29 kV 43 kV
  • Quoted to your quantity
  • Documentation on request
  • International delivery

Product Overview

These cables are used for the connection of mobile operating equipments, in mines and underground excavations with hazardous environments, in stationary operation, e.g.high-voltage transformers in mining and tunneling.

Technical Specifications

Rated Voltage3,6/6 kV 6/10 kV 8,7/15 kV 12/20 kV 18/30 kV
Working TemperatureAccording to DIN VDE 0298, Part 4
ColourRed or Black
AC Test Voltage11 kV 17 kV 24 kV 29 kV 43 kV
Max. Permissible Operating Voltage AC4,2/7,2 kV 6,9/12 kV 10,4/18 kV 13,9/24 kV 20,8/36 kV
Max. Permissible Operating Voltage DC5,4/10,8 kV 9/18 kV 13,5/27 kV 18/36 kV 27/54 kV
Min. Bending Radius Current Carrying CapacityAcc. to DIN VDE 0298 part 3
Fixed-40ºC … +80ºC
Mobile+5ºC … +80ºC
Max. Tensile Load of cable20 N/mm²
Max. Torsion25º/m
Travel Speedmax. 30 m/min.
Minimum distance for change of direction20 X D

Conductors Flexible electrolytic copper wire acc. to DIN VDE 0295 – Class 5
Insulation Main Cores 3GI3 type EPR compound
Pilot Control Cores 3GI3 type EPR compound
Protective Conductor Made of plain copper wires or copper wire braiding laid-up concentrically around each main core
Electrical Field Control Extruded inner and outer rubber semi conductive layer For 3,6/6
Core Identification Main Cores Natural coloring, design acc. to DIN VDE 0250 Part.1
Pilot Cores Black colored and number coded
Lay Up Three main conductors laid-up with three pilot control cores in the outer interstice Protective cores are concentrically wrapped over insulation of power cores
Inner Sheath YM5 type PVC Compound
Monitoring Conductor Semi conductive tape + overall concentric lay of copper wires and syntetic tape over wires
Inner Sheath Armour PVC compound type DMV6 acc. to DIN VDE 0276-603 Galvanized steel wire braiding, coverage minimum 75 % ST2 Type to IEC 60502
Outer Sheath PVC compound type DMV6 acc. to DIN VDE 0276-603

Cross Section (mm2)Overall Diameter Mln-Max (mm)Conductor Resistance At 20 °C (Ω/km)Approxlmate welght (kg/km)
3,6/6 kV
3×25 + 3×16/3E + 3×2,5st + .L47.0 – 51.00.7803600
3×70 + 3×35/3E + 3×2,5st + .L56.1 – 61.20.2725900
3×95 + 3X50/3E + 3×2,5st + .L60.3 – 66.20.2065900
3×120 + 3×70/3E + 3×2,5st + .L63.8 – 70.20.1618620
3×150 + 3×70/3E + 3×2,5st + .L66.0 – 72.00.1299860
3×185 + 3×95/3E + 3×2,5st + .L70.0 – 74.00.10611300
6/10 kV
3×25 + 3×16/3E + 3×2,5st + .L54.0 – 57.00.7804200
3×35 + 3×16/3E + 3×2,5st + .L57.1 – 60.20.5544650
3×50 + 3×25/3E + 3×2,5st + .L60.4 – 63.60.3865380
3×70 + 3×35/3E + 3×2,5st + .L65.2 – 68.80.2726450
3×95 + 3X50/3E + 3×2,5st + .L68.0 – 71.90.2067700
3×120 + 3×70/3E + 3×2,5st + .L70.1 – 76.10.1619260
3×150 + 3×70/3E + 3×2,5st + .L73.0 – 78.00.12910840
3×185 + 3×95/3E + 3×2,5st + .L74.0 – 79.20.10612400
8,7/15 kV
3×25 + 3×16/3E + 3×2,5st + .L54.2 – 58.00.7804530
3×35 + 3×16/3E + 3×2,5st + .L55.0 – 60.00.5545100
3×50 + 3×25/3E + 3×2,5st + .L58.0 – 61.00.3865840
3×70 + 3×35/3E + 3×2,5st + .L65.2 – 67.00.2727840
3×95 + 3X50/3E + 3×2,5st + .L66.0 – 69.00.2069120
12/20 kV
3×25 + 3×16/3E + 3×2,5st + .L54.4 – 58.20.7804920
3×35 + 3×16/3E + 3×2,5st + .L55.4 – 60.00.5545400
3×50 + 3×25/3E + 3×2,5st + .L58.0 – 61.00.3866200
3×70 + 3×35/3E + 3×2,5st + .L65.2 – 67.00.2727320
3×95 + 3X50/3E + 3×2,5st + .L66.0 – 69.00.2068630
3×120 + 3×70/3E + 3×2,5st + .L68.7 – 74.00.1619260
3×150 + 3×70/3E + 3×2,5st + .L74.0 – 78.00.12910460
3×185 + 3×95/3E + 3×2,5st + .L78.0 – 82.00.10611870

Features

  • Ozone resistant
  • Cold resistant
  • Tear resistant
  • UV resistant
  • Weather resistant
  • Moisture resistant

Certifications / Standards

  • GOST R

Request Information About This Product

Tell us your quantity and requirements — we reply within one business day.

Related Products

(N)3GHSSHCH Tunnelling CableTunnelling Cables
Cables

(N)3GHSSHCH Tunnelling Cable

These cables are used for the connection of mobile operating equipments, in mines and underground excavations with hazardous environments, in stationary operation, e.g.high-voltage transformers in mining and tunnelling.

3,6/6 kV 6/10 kV 8,7/15 kV 2/20 kV… · According to DIN VDE 0298, Part 4

Have a product requirement?

Share your specifications and quantities. Our team will review your request and come back with sourcing options and a quotation.