Product Overview
Abtech SSD aluminium electrical enclosures and junction boxes are ATEX certified and suitable for Zone 1 and Zone 2 hazardous areas. The Ex d enclosure designed to house electrical and electronic apparatus within Zone 1 and 21 hazardous areas.
Abtech SSD aluminium has a flameproof design that allows potentially sparking equipment to be safely installed in areas where explosive gases or dust may be present. The SSD-AL comes painted externally to RAL7001 grey providing significant levels of environmental protection.
Abtech SSD Features
- Ambient temperature range of – 20°C to + 40°C
- Zone 1 & Zone 2 Hazardous Area Certified By ATEX
- Flameproof Enclosure
- IP66 to EN60529 rating
- Up to 24kV ac or 1500V dc voltage rating
Zone 1
A hazardous area location according to ATEX in which an explosive atmosphere consisting of a mixture with air of flammable substances in the form of gas, vapour or mist is likely to occur in normal operation occasionally.
Zone 2
A hazardous area location according to ATEX in which an explosive atmosphere consisting of a mixture with air of flammable substances in the form of gas, vapour or mist is not likely to occur in normal operation but, if it does occur, persists for a short period only.
ATEX Explained
The ATEX Directive consists of two EU directives describing the type of equipment and hazardous area location within a potentially explosive atmosphere. ATEX originates its name from the French title of the 94/9/EC directive: Appareils destinés à être utilisés en ATmosphères EXplosibles.
Cable entries can be drilled in the enclosure or junction box door, sides or via the cable gland plates – cable entries can also be drilled through the rear face of the stainless steel enclosure (EEx’e’ hazardous area versions).
The hazardous area enclosures include a hinged, lift-off door secured to the junction box using 4 captive stainless steel screws which also maintain the correct compression on the gasket.
Hazardous Area Certification
Abtech SSD aluminium enclosures are certified according to leading hazardous area classifications including:
- Area Classification – Group IIB Category 2 GD (Zone 1/21 and 2/22), Option: Group IIB+ H2 Category 2 GD (Zone 1/21 and 2/22)
- Type of Protection – Ex db (Flameproof), Ex tb (Dust), Ex db [ia/ib] (Intrinsically Safe)*
- Apparatus Coding – Ex db IIB or IIB+H2 T* Gb, Ex tb* IIIC T* °C Db
Ex db [ia Ga] IIB or IIB+H2 T6 Gb, Ex tb [ia Da] IIIC T85 °C Db
Ex db [ib Gb] IIB or IIB+H2 T6 Gb, Ex tb [ib Db] IIIC T85 °C Db
- Certificate Number – INERIS 13ATEX0019X / IECEx INE14.0061X
- Zone 1 Hazardous Area Lighting
- Zone 2 Hazardous Area Lighting
- Enclosures, Motor Starters & Isolators