Marine CablesM2XH (NOFI) Marine Cable
Used as fixed installation cables in various electromechanical and electronic equipments of marine vehicles, in most areas & on open deck in ships.

It is used as a fixed connection cable in electromechanical and electronic devices. Thanks to its shielded design, electromagnetic interference with the surrounding environment is minimised. It is used in…
It is used as a fixed connection cable in electromechanical and electronic devices. Thanks to its shielded design, electromagnetic interference with the surrounding environment is minimised. It is used in ships for motor supply cables and in VFD (Variable Frequency Drive) applications, specifically for frequency converter connections controlling low-voltage AC drives.
* The recommended minimum cable installation temperature is -15°C.
Please refer to the technical specifications section for conductor designations, diameter tolerances and other details.
| Rated voltage | 0.6 / 1 kV |
|---|---|
| Conductor | Electrolytic, annealed and stranded copper wire, IEC 60228, Class 2 (Class 5 and/or tinned available on request) |
| Insulation | Cross-linked polyethylene (XLPE) |
| Outer sheath | Halogen-free, flame-retardant, polyolefin-based compound (SHF 1) |
| Operating temperature | -40°C / +90°C |
| Separator | Separator foil and/or halogen-free compound |
| Screen | 100% coverage copper/polyester tape and min. 90% coverage copper braided shield (tinned copper wires optional) |
| Colour | Black or Grey |
| Construction | IEC 60092 / 353 |
| Tests and materials | IEC 60092 / 350-360 |
| Flame retardance | IEC 60332 / 1-2, IEC 60332 / 3-22 Cat A |
| Halogen content | IEC 60754 / 1-2 |
| Smoke density | IEC 61034 / 1-2 (DIN EN 50268 / 1-2) |
| Ozone resistance | IEC 60811 / 403 |
| SCREENING EFFICIENCY (for EMC Type) | DIN EN 50147-1 |
| Min. bending radius (fixed) | 6 x D |
| Test voltage | 3.5 kV |
| UV and sunlight resistance | EN 50289-4-17 A&B, ISO 4892-2&3 |
| Nominal Cross-Section (mm²) | Cable Outer Diameter (mm) | Approximate Cable Weight (kg/km) | Minimum bending radius (fixed) (mm) | Maximum electrical resistance at 20°C (ohms/km) | Current-carrying capacity at 45°C (A) |
|---|---|---|---|---|---|
| 2×1 | 10.4 | 175 | 62 | 18.1 | 15 |
| 2×1,5 | 11.2 | 205 | 67 | 12.1 | 20 |
| 2×6 | 14.8 | 412 | 89 | 3.08 | 44 |
| 2×10 | 16.8 | 556 | 101 | 1.83 | 61 |
| 2×16 | 19 | 748 | 114 | 1.15 | 82 |
| 2×25 | 22.4 | 1056 | 135 | 0.727 | 108 |
| 2×35 | 25.2 | 1342 | 151 | 0.524 | 133 |
| 2×50 | 28.4 | 1766 | 170 | 0.387 | 167 |
| 2×70 | 32.4 | 2377 | 194 | 0.268 | 206 |
| 2×95 | 36.8 | 3183 | 221 | 0.193 | 249 |
| 2×120 | 40.4 | 3895 | 242 | 0.153 | 288 |
| 2×150 | 45.4 | 4853 | 272 | 0.124 | 331 |
| 2×185 | 50.6 | 6014 | 304 | 0.0991 | 337 |
| 2×240 | 56.4 | 7641 | 338 | 0.0754 | 444 |
| 3×1 | 10.8 | 197 | 65 | 18.1 | 13 |
| 3×1,5 | 11.8 | 223 | 71 | 12.1 | 16 |
| 3×2,5 | 12.6 | 274 | 76 | 7.41 | 21 |
| 3×4 | 14.7 | 390 | 88 | 4.61 | 28 |
| 3×6 | 15.7 | 479 | 94 | 3.08 | 36 |
| 3×10 | 17.7 | 659 | 106 | 1.83 | 50 |
| 3×16 | 20.3 | 915 | 122 | 1.15 | 67 |
| 3×25 | 23.6 | 1294 | 142 | 0.727 | 89 |
| 3×35 | 26.7 | 1654 | 160 | 0.524 | 110 |
| 3×50 | 30.2 | 2199 | 181 | 0.387 | 137 |
| 3×70 | 34.5 | 2990 | 207 | 0.268 | 169 |
| 3×95 | 39.4 | 4036 | 236 | 0.193 | 205 |
| 3×120 | 43.3 | 4970 | 260 | 0.153 | 237 |
| 3×150 | 48.5 | 6171 | 291 | 0.124 | 272 |
| 3×185 | 54 | 7657 | 324 | 0.0991 | 311 |
| 3×240 | 60.5 | 9837 | 363 | 0.0754 | 365 |
| 4×1 | 11.7 | 220 | 70 | 18.1 | 13 |
| 4×1,5 | 12.6 | 264 | 76 | 12.1 | 16 |
| 4×2,5 | 13.7 | 328 | 82 | 7.41 | 21 |
| 4×4 | 15.6 | 462 | 94 | 4.61 | 28 |
| 4×6 | 17.1 | 589 | 103 | 3.08 | 36 |
| 4×10 | 19.3 | 810 | 116 | 1.83 | 50 |
| 4×16 | 22 | 1123 | 132 | 1.15 | 67 |
| 4×25 | 26 | 1608 | 156 | 0.727 | 89 |
| 4×35 | 29.4 | 2030 | 176 | 0.524 | 110 |
| 4×50 | 33.9 | 2818 | 204 | 0.387 | 137 |
| 4×70 | 38.5 | 3881 | 231 | 0.268 | 169 |
| 4×95 | 43.4 | 5123 | 260 | 0.193 | 205 |
| 4×120 | 48.5 | 6398 | 291 | 0.153 | 237 |
| 4×150 | 54 | 7913 | 324 | 0.124 | 272 |
| 4×185 | 60.6 | 9905 | 364 | 0.0991 | 311 |
| 4×240 | 67.9 | 12722 | 408 | 0.0754 | 365 |
| 5×1 | 12.4 | 247 | 75 | 18.1 | 10 |
| 5×1,5 | 13.4 | 294 | 81 | 12.1 | 13 |
| 5×2,5 | 15.4 | 407 | 93 | 7.41 | 17 |
| 5×4 | 17.1 | 538 | 103 | 4.61 | 24 |
| 5×6 | 18.5 | 679 | 111 | 3.08 | 30 |
| 5×10 | 21.1 | 951 | 127 | 1.83 | 42 |
| 5×16 | 24 | 1355 | 144 | 1.15 | 56 |
| 5×25 | 28.6 | 1937 | 172 | 0.727 | 74 |
| 5×35 | 32.9 | 2539 | 198 | 0.524 | 91 |
| 5×50 | 37.6 | 3400 | 226 | 0.387 | 114 |
| 5×70 | 42.7 | 4709 | 256 | 0.268 | 140 |
| 5×95 | 50 | 6380 | 300 | 0.193 | 170 |
| 5×120 | 54.9 | 7883 | 330 | 0.153 | 197 |
| 5×150 | 60.9 | 9670 | 366 | 0.124 | 226 |
| 5×185 | 68.1 | 12006 | 409 | 0.0991 | 258 |
| 5×240 | 76.2 | 15466 | 457 | 0.0754 | 303 |
Tell us your quantity and requirements — we reply within one business day.
Marine CablesUsed as fixed installation cables in various electromechanical and electronic equipments of marine vehicles, in most areas & on open deck in ships.
Marine CablesUsed as fixed installation cables in various electromechanical and electronic equipments of marine vehicles. Due to its’ overall screen, environmental electromagnetic interference is minimized.
Marine CablesUsed as fixed installation cables in various electromechanical and electronic equipments of marine vehicles.
Share your specifications and quantities. Our team will review your request and come back with sourcing options and a quotation.