Marine CablesM2XH (NOFI) Marine Cable
Used as fixed installation cables in various electromechanical and electronic equipments of marine vehicles, in most areas & on open deck in ships.

Used as fixed installation cables in various electromechanical and electronic equipments. Due to its’ overall screen the electromagnetic interference is minimized. It can be used as motor supply cable and…
Used as fixed installation cables in various electromechanical and electronic equipments. Due to its’ overall screen the electromagnetic interference is minimized. It can be used as motor supply cable and for frequency converters controlled low voltage AC drives on ships, called VFD applications.
*Minimum recommended installation temperature -15°C
For core identification, diameter tolerances and current ratings etc. see technical information section
| Rated voltage | 1,8 / 3 (3,6) kV |
|---|---|
| Conductor | Electrolytic, stranded, annealed copper wire IEC 60228 Class 2 (Class 5 and / or tinned on request) |
| Insulation | Cross linked polyethylene compound (XLPE). |
| Outer sheath | Halogen-free, flame retardant, UV resistant, polyolefin based compound (SHF1). |
| Working temperature | -40°C / + 90°C |
| Inner covering | Separating foil and / or halogen-free compound |
| Screen | Copper / poylester tape coverage 100% and copper wire braided screen min.coverage 90% (Tinned copper wire braid on request) |
| Color | Black or Grey. |
| Construction | IEC 60092 / 353 |
| Tests and material | IEC 60092 / 350-360 |
| Flame retardant | IEC 60332 / 1-2, IEC 60332 / 3-22 Cat A |
| Halogen content | IEC 60754 / 1-2 |
| Smoke emission | IEC 61034 / 1-2 (DIN EN 50268 / 1-2) |
| Ozon resistance | IEC 60811 / 403 |
| Shielding effectivenes (for EMC type) | DIN EN 50147-1 |
| Min. bending radius (fixed) | 6 x D |
| Test voltage | 6,5 kV |
| UV and sunlight resistance | EN 50289-4-17 A&B, ISO 4892-2&3 |
| Cross Section (mm²) | Nominal Overall Diameter (mm) | Approximate Weight (kg / km) | Min. Bending Radius Fixed Installed (mm) | Max Resistance of Conductors at 20°C (ohm / km) | Current Carrying Capacity at 45°C (A) |
|---|---|---|---|---|---|
| 1×10 | 13 | 295 | 78 | 1.83 | 72 |
| 1×16 | 14.6 | 411 | 88 | 1.15 | 96 |
| 1×50 | 18.5 | 791 | 111 | 0.387 | 196 |
| 1×70 | 20.2 | 1022 | 121 | 0.268 | 242 |
| 1×95 | 22.3 | 1324 | 134 | 0.193 | 293 |
| 1×120 | 23.8 | 1585 | 143 | 0.153 | 339 |
| 1×150 | 25.7 | 1908 | 154 | 0.124 | 389 |
| 1×185 | 27.8 | 2315 | 167 | 0.0991 | 444 |
| 1×240 | 30.4 | 2919 | 183 | 0.0754 | 522 |
| 3×10 | 23.4 | 933 | 140 | 1.83 | 50 |
| 3×16 | 25.8 | 1214 | 155 | 1.15 | 67 |
| 3×25 | 28.3 | 1564 | 170 | 0.727 | 89 |
| 3×35 | 31.3 | 1950 | 188 | 0.524 | 110 |
| 3×50 | 34.7 | 2540 | 208 | 0.387 | 137 |
| 3×70 | 38.7 | 3400 | 232 | 0.268 | 169 |
| 3×95 | 43 | 4390 | 258 | 0.193 | 205 |
| 3×120 | 47.1 | 5382 | 283 | 0.153 | 237 |
| 3×150 | 50.9 | 6464 | 305 | 0.124 | 272 |
| 3×185 | 53.8 | 7928 | 323 | 0.0991 | 311 |
| 3×240 | 63.3 | 9480 | 380 | 0.0754 | 365 |
Tell us your quantity and requirements — we reply within one business day.
Marine CablesUsed as fixed installation cables in various electromechanical and electronic equipments of marine vehicles, in most areas & on open deck in ships.
Marine CablesUsed as fixed installation cables in various electromechanical and electronic equipments of marine vehicles. Due to its’ overall screen, environmental electromagnetic interference is minimized.
Marine CablesUsed as fixed installation cables in various electromechanical and electronic equipments of marine vehicles.
Share your specifications and quantities. Our team will review your request and come back with sourcing options and a quotation.