Offshore CablesBFOU (NEK 606 P5/P12) Offshore Cable
Used as fixed installation cables in various electromechanical and electronic equipments, emergency and critical systems as well as electric distribution and lightning systems.

These cables are used for fixed installations in all areas and on open deck in ships and offshore units
These cables are used for fixed installations in all areas and on open deck in ships and offshore units
| Conductor | Electrolytic annealed, class 2 or class 5 stranded tinned copper wires |
|---|---|
| Insulation | GP4 Type elastomer compound |
| Outer sheath | SW4 Type elastomer compound |
| Working temperature | Sabit / Fixed : -25ºC…+85ºC |
| Flame barrier | Mica tape |
| Core identification | White insulation with black numbered |
| Laying-up | Twisted pair or triple cores are stranded in layers |
| Shielding | Each pair wrapped with Al-pet foil and drain wire |
| Inner sheath | SW4 Type elastomer compound |
| Armour | Galvanised steel wire braiding (min.85%) |
| Color | Black (other colors on request) |
| Conductor operating temperature | Max. 90ºC |
| Conductor short-circuit temperature | Max. 250ºC |
| Flame retardant | IEC 60332-3-22 Cat.A |
| Fire resistant | IEC 60331 (180 Min.) |
| NO.CONDUCTORS X CROSS -SECTION (mm2) | INNER SHEAT DIA. Min.-Max (mm) | OUTER DIAMETER Min.-Max (mm) | COPPER FACTOR (kg / km) | CABLE WEIGHT (kg / km) |
|---|---|---|---|---|
| 1Q0,75 | 9,6 – 11,2 | 13,4 – 15,3 | 33,6 | 305 |
| 3P0,75 | 14,9 – 16,8 | 19 – 21,4 | 57.6 | 584 |
| 1P1 | 7,9 – 9,2 | 11,6 – 13,5 | 24 | 286 |
| 2P1,5 | 14,9 – 16,5 | 19,3 – 21,5 | 67.2 | 602 |
| 3P1,5 | 15,9 – 17,5 | 20,4 – 22,8 | 100.8 | 732 |
| 5P1,5 | 19,5 – 21,4 | 24,2 – 26,7 | 168 | 1031 |
| 7P1,5 | 21,5 – 23,6 | 26,5 – 29,1 | 235.2 | 1242 |
| 10P1,5 | 27,4 – 29,6 | 33,6 – 36,7 | 336 | 1877 |
| 12P1,5 | 28,6 – 30,8 | 34,8 – 37,9 | 403.2 | 2039 |
| 20P1,5 | 36,1 – 38,4 | 42,9 – 46,7 | 672 | 3232 |
| 3TR0,75 | 15 – 17 | 19,2 – 21,6 | 79.2 | 783 |
| 7TR0,75 | 19,9 – 22,3 | 24,4 – 27,4 | 184.8 | 1329 |
| 12TR0,75 | 26,9 – 29,7 | 32 – 35,8 | 316.8 | 2258 |
| 1TR1 | 8,9 – 10,2 | 12,6 – 14,5 | 33.6 | 305 |
Tell us your quantity and requirements — we reply within one business day.
Offshore CablesUsed as fixed installation cables in various electromechanical and electronic equipments, emergency and critical systems as well as electric distribution and lightning systems.
Offshore CablesFixed installation cable for power, control and lighting
Offshore CablesUsed as fixed installation cables in various electromechanical and electronic equipments, emergency and critical systems as well as electric distribution and lightning systems.
Share your specifications and quantities. Our team will review your request and come back with sourcing options and a quotation.