Marine CablesM2XH (NOFI) Marine Cable
Used as fixed installation cables in various electromechanical and electronic equipments of marine vehicles, in most areas & on open deck in ships.

Medium Voltage power distribution, electric power transport between the engine room generator and
Medium Voltage power distribution, electric power transport between the engine room generator and
electrical machines. Used as fixed installation cables in various electromechanical and electronic equipments.
Due to its’ overall screen the electromagnetic interference is minimized.
* Minimum recommended installation temperature -15°C
For core identification, diameter tolerances and current ratings etc. see technical information section
| Rated voltage | 8,7 / 15 kV |
|---|---|
| Conductor | Electrolytic, stranded, annealed copper wire IEC 60228 Class 2 (Class 5 and / or tinned on request) |
| Insulation | HF HEPR Compound |
| Outer sheath | Halogen-free, flame retardant, UV resistant, polyolefin compound, SHF 1 (SHF2 on request) |
| Working temperature | -40°C / + 90°C |
| Conductor screen | Semiconductive layer |
| Insulation screen | Semiconductive layer |
| Core screen | Copper Tape |
| Bedding | Halogen-free bedding compound |
| Screen | Electrolytic copper braided screen (90% coverage) (Tinned copper wire braid on request) |
| Color | Red |
| Construction | IEC 60092 / 354 |
| Tests and material | IEC 60092 / 350-360 |
| Flame retardant | IEC 60332 / 1-2, IEC 60332 / 3-22 Cat A |
| Halogen content | IEC 60754 / 1-2 |
| Smoke emission | IEC 61034 / 1-2 (DIN EN 50268 / 1-2) |
| Ozon resistance | IEC 60811 / 403 |
| Shielding effectivenes (for EMC type) | DIN EN 50147-1 |
| Min. bending radius (fixed) | For Single Core Cables 12 x D – For 3 Core Cables 9 x D |
| Test voltage | 30,5 kV |
| UV and sunlight resistance | EN 50289-4-17 A&B, ISO 4892-2&3 |
| Cross Section (mm²) | Nominal Overall Diameter (mm) | Approximate Weight (kg / km) | Min. Bending Radius Fixed Installed (mm) | Max Resistance of Conductors at 20°C (ohm / km) | Current Carrying Capacity at 45°C (A) |
|---|---|---|---|---|---|
| 1 x 25 | 25,5-29,5 | 1100 | 354 | 0.727 | 127 |
| 1 x 35 | 27,0-31,3 | 1260 | 376 | 0.524 | 157 |
| 1 x 95 | 31,3-36,2 | 2000 | 434 | 0.193 | 293 |
| 1 x 120 | 33,9-39,2 | 2420 | 470 | 0.153 | 339 |
| 1 x 150 | 35,8-41,4 | 2840 | 496 | 0.124 | 389 |
| 1 x 185 | 37,6-43,5 | 3250 | 522 | 0.0991 | 444 |
| 1 x 240 | 40,3-46,7 | 3970 | 560 | 0.0754 | 522 |
| 1 x 300 | 42,6-49,3 | 4650 | 592 | 0.0601 | 601 |
| 3 x 25 | 49,2-56,9 | 3900 | 512 | 0.727 | 89 |
| 3 x 35 | 52,2-60,4 | 4450 | 544 | 0.524 | 110 |
| 3 x 50 | 54,5-63,0 | 5070 | 567 | 0.387 | 137 |
| 3 x 70 | 58,1-67,3 | 6030 | 606 | 0.268 | 169 |
| 3 x 95 | 62,0-71,8 | 7220 | 646 | 0.193 | 205 |
| 3 x 120 | 65,0-75,3 | 8300 | 678 | 0.153 | 237 |
| 3 x 150 | 69,9-80,9 | 9600 | 728 | 0.124 | 272 |
| 3 x 185 | 73,8-85,4 | 11150 | 768 | 0.0991 | 311 |
| 3 x 240 | 79,1-91,6 | 13550 | 824 | 0.0754 | 365 |
| 3 x 300 | 85,0-98,4 | 16300 | 886 | 0.0601 | 421 |
Tell us your quantity and requirements — we reply within one business day.
Marine CablesUsed as fixed installation cables in various electromechanical and electronic equipments of marine vehicles, in most areas & on open deck in ships.
Marine CablesUsed as fixed installation cables in various electromechanical and electronic equipments of marine vehicles. Due to its’ overall screen, environmental electromagnetic interference is minimized.
Marine CablesUsed as fixed installation cables in various electromechanical and electronic equipments of marine vehicles.
Share your specifications and quantities. Our team will review your request and come back with sourcing options and a quotation.