Type P Power Cable Single Conductor 2kV Unarmoured

These cables are intended for use as power cables aboard ship and on off-shore oil rings. The cables are constructed in accordance with the recommended practice for marine cable for…

Rated voltage2 kV
ConductorSoft annealed flexible stranded tinned copper wire acc. to IEEE 1580 Table 11
InsulationCross-linked polyolefin compound, in accordance with Type P of IEEE 1580 and Type X110 of UL 1309/CSA C22.2 No.245.
SeparatorA suitable separator tape may be applied to the conductor (optional for manufacturer)
  • Quoted to your quantity
  • Documentation on request
  • International delivery

Product Overview

These cables are intended for use as power cables aboard ship and on off-shore oil rings. The cables are constructed in accordance with the recommended practice for marine cable for use on fixed or floating facilities, IEEE 1580. Excellent resistance to oil, abrasion petrochem fluids, moisture salty water and sunlight.

Technical Specifications

Rated voltage2 kV
ConductorSoft annealed flexible stranded tinned copper wire acc. to IEEE 1580 Table 11
InsulationCross-linked polyolefin compound, in accordance with Type P of IEEE 1580 and Type X110 of UL 1309/CSA C22.2 No.245.
SeparatorA suitable separator tape may be applied to the conductor (optional for manufacturer)
Reference standardsIEEE 1580, UL 1309, CSA C22.2 No.245, IEEE 45
Insulation materialIEEE 1580, UL 1309, CSA C22.2 No.245
Sheath materialIEEE 1580, UL 1309, CSA C22.2 No.245
Conductor materialASTM B 33
Conductor resistanceIEEE 1580 Table 11
Flame propagationIEEE 1202, IEC 60332-3
Cold bend (-40)CSA C22.2
Cold impact (-35)CSA C22.2
Temperature rating IEEE 1580100°C (Single Core 125°C)
Temperature rating UL 1309110°C (Single Core 125°C)
Test voltageIEEE 1580 Table 19; MIN. BENDING RADIUS
For D≤25 mm4 x D
For D>25 mm6 x D
Current carrying capacityIEEE 45.8
* canCable Article Number; * This can numbers for Black outer sheath

** Ambient air temperature at 45 °C

CAN*Cable TypeCross-SectionOuter Sheath DiameterApprox. Cable Weight (kg/km)Min. Bending Radius (mm)Current Carrying Capacity 100°C (**) (A)Current Carrying Capacity 110°C (**) (A)Max. Electrical Resistance at 20°C (ohm/km)
Min. (mm)Nom. (mm)Max. (mm)
6416.1SP-2-2kV1×18 AWG3,53,84,52318161720,384
6416.4SP-7-2kV1×12 AWG4,54,85,5482245486,292
6416.5SP-10-2kV1×10 AWG5,25,66,5752658623,538
6416.6SP-17-2kV1×8 AWG6,46,88,01073272772,46
6416.7SP-26-2kV1×6 AWG7,47,99,016036961031,539
6416.8SP-33-2kV1×5 AWG8,48,910,0223401091171,137
6416.9SP-42-2kV1×4 AWG9,29,711,0259441281370,902
6416.10SP-53-2kV1×3 AWG10,010,511,5318461461560,715
6416.11SP-66-2kV1×2 AWG10,511,212,5376501691810,568
6416.12SP-84-2kV1×1 AWG12,513,314,5536581942080,412
6416.13SP-106-2kV1×1/0 AWG13,014,015,5605622272430,363
6416.14SP-133-2kV1×2/0 AWG14,515,417,0762682622810,284
6416.15SP-168-2kV1×3/0 AWG16,517,319,0989763003210,206
6416.16SP-212-2kV1×4/0 AWG17,518,620,01.179803513760,171
6416.17SP-262-2kV1×262 kcmil19,520,622,51.431904074360,148
6416.18SP-313-2kV1×313 kcmil21,021,923,51.652944554870,123
6416.19SP-373-2kV1×373 kcmil22,523,625,51.9471535165530,103
6416.20SP-444-2kV1×444 kcmil24,025,427,52.3131655886300,086
6416.21SP-535-2kV1×535 kcmil27,028,330,52.8051836306760,072
6416.22SP-597-2kV1×597 kcmil28,029,531,53.0991896706780,07
6416.23SP-646-2kV1×646 kcmil29,530,733,03.3921987317830,06
6416.24SP-777-2kV1×777 kcmil31,533,135,54.0262138228810,05
6416.25SP-1111-2kV1×1111 kcmil38,039,842,55.7982551.0251.0980,035