Mining CablesAS/NZS 2802 Type 455 Mining Cable
General use cable for mines (except for underground coal mines). Suitable to trailing and reeling due to its’ smaller dimensions.

For the connection of electrical equipment, large material handling machines such as excavators, cranes, dumpers in mining and tunelling applications. The flexible cable design allows for movement of the equipment…
For the connection of electrical equipment, large material handling machines such as excavators, cranes, dumpers in mining and tunelling applications. The flexible cable design allows for movement of the equipment during operation.
| Rated voltage | 3,6/6 kV 6/10 kV 8,7/15 kV 12/20 kV 18/30 kV |
|---|---|
| Conductor | Electrolytic, stranded, tinned copper wire DIN VDE 0295 Class 5 |
| Insulation | 3GI3 Type EPR Compound |
| Outer sheath | 5GM5 Type elastomer compound |
| Electrical field control | Inner and Outer Semiconductive layer of semiconductive rubber |
| Protective-earth conductor | Tinned Copper conductor with semiconductive layer |
| Lay up | Three main conductors laid-up with three control cores in the outer interstice |
| Inner sheath | GM1b Type EPR Compound |
| Reinforcement | Embedded braid made of anti torsion synthetic threads |
| Colour | Red |
| AC test voltage | 11 kV 17 kV 24 kV 29 kV 43 kV; MAX. PERMISSIBLE |
| Operating voltage AC | 4,2/7,2 kV 6,9/12 kV 10,4/18 kV 13,9/24 kV 20,8/36 kV |
| Min bending radius | Acc. to DIN VDE 0298 part 3 |
| Current carrying capacity | According to DIN VDE 0298, Part 4; WORKING TEMPERATURE : |
| Fixed | -40ºC … +80ºC |
| Mobile | -25ºC … +80ºC |
| Max. tensile load of cable | 15 N/mm² |
| Max. torsion | 25º/m |
| Travel speed for tunelling app. | max. 30 m/min. |
| Min. distarce for change of direction | 20 X D |
| Cross Sectlon (mm2) | Overall Dlameter Mln-Max (mm) | Approxlmate welght (kg/km) |
|---|---|---|
| 3,6/6 kV | ||
| 3 x 25 + 3 x 25/3 | 41.8 – 45.0 | 2530 |
| 3 x 70 + 3 x 35/3 | 52.6 – 55.6 | 4400 |
| 3 x 95 + 3 x 50/3 | 55.7 – 58.8 | 5630 |
| 3 x 120 + 3 x 70/3 | 59.6 – 65.9 | 6200 |
| 6/10 kV | ||
| 3 x 25 + 3 x 25/3 | 43.6 – 48.1 | 2600 |
| 3 x 35 + 3 x 25/3 | 45.6 – 50.4 | 2980 |
| 3 x 50 + 3 x 25/3 | 48.3 – 51.4 | 3720 |
| 3 x 70 + 3 x 35/3 | 53.4 – 59.1 | 4510 |
| 3 x 95 + 3 x 50/3 | 57.1 – 63.2 | 5720 |
| 3 x 120 + 3 x 70/3 | 63.0 – 69.7 | 6300 |
| 8,7/15 kV | ||
| 3 x 25 + 3 x 25/3 | 48.1 – 53.2 | 3675 |
| 3 x 35 + 3 x 25/3 | 51.8 – 57.3 | 4415 |
| 3 x 50 + 3 x 25/3 | 55.5 – 61.4 | 5135 |
| 3 x 70 + 3 x 35/3 | 58.0 – 64.1 | 6005 |
| 3 x 95 + 3 x 50/3 | 63.4 – 70.1 | 7200 |
| 3 x 120 + 3 x 70/3 | 67.5 – 74.6 | 8700 |
| 12/20 kV | ||
| 3 x 25 + 3 x 25/3 | 51.1 – 55.3 | 4460 |
| 3 x 35 + 3 x 25/3 | 54.0 – 58.2 | 4990 |
| 3 x 50 + 3 x 25/3 | 59.4 – 63.6 | 5740 |
| 3 x 70 + 3 x 35/3 | 64.2 – 68.4 | 6950 |
| 3 x 95 + 3 x 50/3 | 69.6 – 73.8 | 7870 |
| 3 x 120 + 3 x 70/3 | 73.60 – 77.8 | 9425 |
| 18/30 kV | ||
| 3 x 25 + 3 x 25/3 | 66.0 – 72.8 | 6360 |
| 3 x 35 + 3 x 25/3 | 68.0 – 75.0 | 6925 |
| 3 x 50 + 3 x 25/3 | 71.6 – 79.1 | 7800 |
| 3 x 70 + 3 x 35/3 | 75.8 – 83.7 | 9140 |
| 3 x 95 + 3 x 50/3 | 79.4 – 87.7 | 10100 |
| 3 x 120 + 3 x 70/3 | 85.3 – 94.2 | 12260 |
| 20/35 kV | ||
| 3 x 35 + 3 x 25/3 | 75.7 – 83.6 | 8400 |
| 3 x 50 + 3 x 25/3 | 79.5 – 87.8 | 9360 |
| 3 x 70 + 3 x 35/3 | 82.0 – 90.6 | 10400 |
| 3 x 95 + 3 x 50/3 | 87.3 – 96.4 | 11770 |
| 3 x 120 + 3 x 70/3 | 91.4 – 101.1 | 13680 |
Tell us your quantity and requirements — we reply within one business day.
Mining CablesGeneral use cable for mines (except for underground coal mines). Suitable to trailing and reeling due to its’ smaller dimensions.
Mining CablesGeneral use cable for mines (except for underground coal mines). It has smaller dimensions but strong structure.
Mining CablesGeneral use cable for mines (except for underground coal mines)
Share your specifications and quantities. Our team will review your request and come back with sourcing options and a quotation.