MEDC BG2 Call Point | ATEX IECEx Explosion Proof & Hazardous Area Call Points

BG2 SM87BG are ATEX call points designed for use in the most arduous environmental conditions. The hazardous area call points, manufactured by MEDC, are manually operated fire alarms that are both simple…

CategoryATEX Call Points
  • Quoted to your quantity
  • Documentation on request
  • International delivery

Product Overview

Medc BG2

BG2 SM87BG are ATEX call points designed for use in the most arduous environmental conditions. The hazardous area call points, manufactured by MEDC, are manually operated fire alarms that are both simple to install and maintain in explosive atmospheres in onshore or offshore locations in accordance with the ATEX & IECEx certification and explosion protection levels.

The GRP enclosure of the hazardous area call points are suitable for use offshore or onshore where light weight combined with a high level of corrosion resistance is required.

The Eaton MEDC BG range of Zone 1 & Zone 2 call point caters for numerous options such as variety of colours, LED indication, earth continuity, double switch, etc

Features

Call Point Order Code MEDC BG2.

  • Zone 0, Zone 1 and Zone 2 use.
  • Exed, Exia or weatherproof.
  • ATEX approved call point
    • Ex II 1GD (Exia)
  • BASEEFA certified.
  • IP66 and IP67.
  • Certified temperature of hazardous area call point: –40°C to +50°C (Model dependent).
  • Corrosion resistant red painted GRP.
  • Retained stainless steel cover screws.
  • ATEX call point with optional lift flap.
  • Key operated test facility.
  • Lightweight and robust.
  • Breakglass hammer available (Contact sales office for details).

Hazardous Area Guide

♦ Definition : Potentially explosive atmospheres exist where there is a risk of explosion due to mixtures of gas/air, vapour/air, dust/air or other flammable combinations. Where electrical equipment has to be used in these areas, it must be so designed and constructed such that it does not create sources of ignition capable of igniting these mixtures.
♦ Area Classification : Process plants are divided into Zones (European and IEC method) or Divisions (North American method) according to the likelihood of a potentially explosive atmosphere being present. Note: North American legislation now allows Zones to be used to classify areas, where this practice is used it follows the IEC Zone method.

Eaton MEDC BG2 – Ordering Requirements

The following code is designed to help in selection of the correct MEDC hazardous area call point with ATEX approval and certification. Build up the part number of the call point by inserting the code for each component into the appropriate box.

Medc

MEDC have developed ATEX & IECEx call points designed for harsh and hazardous area conditions and where there is a risk of explosion due to the presence of flammable atmospheres both onshore and offshore – since 1975 MEDC have been designers and manufacturers of Explosion Proof alarm, signal, control and communications equipment.

Explosion Proof & Hazardous Area Call Points | ATEX IECEx | Zone 1 & Zone 2

Technical Specifications

CategoryATEX Call Points
European ATEX & IEC ClassificationDefinition of Zone or DivisionNorth American Classification
Zone 0 (gases)A hazardous area in which an explosive mixture is continuously present or present for long periodsClass I Division I (gases)
Zone 20 (dusts)Class II Division 1 (dusts)
Zone 1 (gases)A hazardous area in which an explosive mixture is likely to occur in normal operationClass I Division 1 (gases)
Zone 21 (dusts)Class II Division 1 (dusts)
Zone 2 (gases)A hazardous area in which an explosive mixture is not likely to occur in normal operation and if it occurs it will exist only for a short timeClass I Division 2 (gases) Class II Division 2 (dusts)
Zone 22 (dusts)Class III Division 1 (fibres) Class III Division 2 (fibres)
Hazardous Area Certifications
ATEX Ex dCert. no. BAS02ATEX2105X. ATEX Approved Ex II 2GD Certified to: EN60079-0, EN60079-1, EN60079-7, EN60079-31 Ex d e IIC T6 Gb, Ex tb IIIC T85°C Db (switch only) Ex d e mb IIC T4 Gb, Ex tb IIIC T135°C Db (with resistors & diodes)
ATEX Ex iaCert no. Baseefa 03ATEX0084X. ATEX Approved Ex II 1 GD Certified to: EN60079-0, EN60079-11 Ex ia IIC T4 Ga, Ex ia IIIC T135°C Da
Specifications
MaterialAnti static UV resistant glass reinforced polyester
FinishPainted red
Certified temp-40°C to +70°C
VoltageUp to 250Vac. Up to 50Vdc (model dependent)
Weight1.2Kg
Ingress protectionIP66 and IP67
Cable entries2 x M20 bottom
Terminals6 x 2.5 sqmm
Resistors valuesEx de – 100Ω minimum, 39 KΩ maximum Ex ia – 470Ω minimum
Switch ratingsSwitch only 30Vdc 5A (resistive) or 3A (inductive) 30-50Vdc 1A (resistive or inductive) 250Vac 5A (resistive or inductive)Resistor(s) 24Vdc 0.05A

Request Information About This Product

Tell us your quantity and requirements — we reply within one business day.

Related Products

Have a product requirement?

Share your specifications and quantities. Our team will review your request and come back with sourcing options and a quotation.