Product Overview

Appleton AMLED Areamaster is part of the Zone 2 (21/22) hazardous area LED luminaire ATEX lighting range that are specifically designed for hazardous Locations. 250 W, 400 W, 750 W HID light level equivalent. The Appleton AMLED Areamaster provides lighting for floodlight and highbay mounting.

AMLED Areamaster provide powerful and reliable operation in efficient weatherproof design – providing hazardous area lighting with savings on installation, maintenance and energy costs due to the compact and efficient design.

The ATEX certified LED luminaires are suitable for the followingapplications include security lighting, production facilities, warehouses, processing plants, storage areas and parking garages and lots.

Features & Benefits

  • Luminaire compact in size, attractively styled contemporary design, rugged and dependable
  • Easy to install and service
  • One-piece housing
  • One-piece lens in hinged cover. Secured by four M6 captive stainless steel slotted hex-head bolts
  • Thermal shock- and impact-resistant glass lens standard
  • Diffused polycarbonate lens available as an option
  • Heavy duty, high temperature silicone rubber gasket, mechanically secured
  • Universal design of hazardous area lighting for flood and high bay mounting
  • Floodlight Mounting:
  • Yoke mount, zinc plated steel yoke with architectural bronze polyester finish
  • High Bay Mounting:
    – (1) Conduit entry on back of luminaire with locking set screw
    – Rotate yoke up or remove
  • Chain Mounting:
    – Mounts via eyebolts threaded into the corners of the fixture
    – Available with chain mounting, or as an accessory
    – Rotate yoke up or remove
    – Cool operating temperatures translate into long luminaire life
    – Available with a total of three (3) 3/4″ NPT entries with integral bushings
    – Two (2) 3/4″ NPT aluminum close up plugs provided
  • Electrical:
    – NEC/CEC: 120-277 250 Vdc available on AMLED77YBC
    – Terminal block (screw type for secure connection) can accept UL/CSA 24-10AWG and
    IEC 0.2 – 4 mm2
    – Vac, 50/60 Hz; 347-480 Vac, 50/60 Hz

Technical Data

*T numbers represent the maximum internal temperature for Class I, Division 2 and Class I, Zone 2 locations designated by the NEC and ATEX/IECEx.

ATEX/IECEx Certifications for hazardous areas

  • Certification Type: AMLED
    — Gas: Zone 2
    – Conforming to ATEX 94/9/EC: II 3 G
    – Protection Level: EPL Gc
    – Ex Protection: Ex nA IIC
    – T Rating: See Temperature Data table on following page
    – EC Declaration of Conformity: 50307
    – ATEX Certificate: LCIE 14 ATEX 1016X
    – IECEx Certificate: IECEx LCIE 14.0030X
    — Dust: Zones 21 and 22
    – Conforming to ATEX 94/9/EC: II 2 D and II 3D
    – Protection Level: EPL Db and Dc
    – Ex Protection: Ex tb IIIC and Ex tc IIIC

IECEX

IECEx LCIE 14.0030X

ATEX

ATEX Certificate, Zone 21: LCIE 14 ATEX 3049X
ATEX Certificate, Zone 22: LCIE 14 ATEX 1016X

NBR IEC Brazilian Certifications and Compliances

• Certification Type: AMLED
— Gas: Zone 2
– IEC Marking: Ex nA IIC Gc
– T Rating: T4
— Dust: Zone 21 and 22
– IEC Marking: Ex tb IIIC Db
– Surface Temperature: T135°C (275°F)
• Ambient Temperature: -25°C to +40°C (-13°F to +104°• Ingress Protection (solid and liquid): IP66
• INMETRO Certificate: TUV 13.0455
• Ex Standards: ABNT NBR IEC 60079-0, ABNT NBR IEC 60079-
15, ABNT NBR IEC 60079-31
• Other Standards: ABNT NBR IEC 60529 (IP)

Technical Specifications

CategoryATEX Lighting (Zone 1 & Zone 2)
LampHazardous Area Classification Gas
Appleton Catalog NumberLine VoltageTypeAmbient Temperature °C (°F)Supply Wire Temperature °C (°F)Class I, Division 2*GroupsExnA IICAExnA IICDust Class II Division 1 Groups E,F,G
AMLED67YBU1120-277 VacLED40 (104)75 (167)T4A,B,C,DT4–
55 (131)90 (194)T3CA,B,C,DT3–
65 (149)90 (194)T3CA,B,C,DT3–
AMLED67YBH347-480 VacLED40 (104)75 (167)T4A,B,C,DT4–
AMLED77YBU1120-277 VacLED40 (104)75 (167)T4A,B,C,DT4–
55 (131)90 (194)T3CA,B,C,DT3–
65 (149)105 (221)T3CA,B,C,DT3–
AMLED77YBH347-480 VacTLED40 (104)75 (167)T4A,B,C,DT4–
NAMLED77YBK220-240 VacLED40 (104)60 (140)T4A,B,C,DT4–
AMLED77YBC250 VacLED40 (104)75 (167)T4AA,B,C,DT4–
AMLED87YBU1120-277 VacLED40 (104)75 (167)T3CA,B,C,DT3–
55 (131)90 (194)T3AA,B,C,DT4–

Request Information About This Product

Tell us your quantity and requirements — we reply within one business day.

Related Products

Have a product requirement?

Share your specifications and quantities. Our team will review your request and come back with sourcing options and a quotation.