Hazardous Area LED Luminaires – Zone 1 Zone 2 ATEX LED LightingZone 2 Hazardous Area LED Lighting – Appleton ATX Linmaster™ LNLED
Please Note: Appleton™ ATX™ Linmaster™ LED Zone 2 Series replaces the FNLED Series Luminaires

Appleton Industrial Areamaster™ Connect LED
Appleton Industrial Areamaster™ Connect LED
The Appleton™ Industrial Areamaster™ Connect LED Luminaire is engineered for top-tier performance and flexibility, offering a next-generation WirelessHART™ connected hazardous area LED lighting solution.
The hazardous area floodlight features adjustable lumen output ranging from 9,500 to 38,000 lumens, while enhancing the WirelessHART™ network. Areamaster™ Connect hazardous area LED luminaire is designed for harsh and hazardous industrial environments Zone 2 (21/22).
Areamaster™ Connect supports various smart control features, such as dimmable output, built-in photocontrol for daylight harvesting, and customised group scheduling. Its integrated 0-10v dimming controller allows for the adjustment of lighting output across a group of dimmable LED luminaires. Additionally, the optional Plantweb™ Insight Connected Lighting Application offers map-based commissioning, energy usage tracking, and maintenance notifications.
In the long term, the Connected Lighting Application tracks system health and energy usage to reduce maintenance needs, while also analysing sustainability metrics, such as CO2 emission reductions.
Typical Applications
The enclosed and gasketed fixtures make the Areamaster™ Connect suitable for use in a wide range of industrial, chemical processing and other areas where flammable gases and vapours are present, including:
• Certification Type: Areamaster Connect LED
— Gas: Zone 2
– Conforming to ATEX 2014/34/EU: II 3G
– Type of Protection: Ex ec IIC Gc
– Temperature Class: AMLCL6, AMLCL8 – T5 to T3; AMLCL3 – T4 to T3
— Dust: Zones 21 and 22
– Conforming to ATEX 2014/34/EU: II 2D
– Type of Protection: Ex tb IIIC Db
– Surface Temperature: +85 °C to +100 °C (+185 °F to +212 °F)
— Dust: Zone 22
– Conforming to ATEX 2014/34/EU: II 3D
– Type of Protection: Ex tc IIIC Dc
– Surface Temperature: +85 °C to +100 °C (+185 °F to +212 °F)
• Ambient Temperature: -40 °C up to +65 °C (-40 °F up to +149 °F).
-40 °C to +55 °C (-40 °F to +131 °F) for high lumen AMLCL3 output.
• ATEX Certificates:
— For Zone 21: INERIS 24ATEX0015X
— For Zone 2 and Zone 22: INERIS 24ATEX3003X
• IECEx Certificate: IECEx INE 24.0029X
• Index of Protection according to EN/IEC 60529: IP66
• Impact Resistance (shock): IK08
• Photobiological Safety, IEC 62778 and IEC 62471: Risk Group 1 (RG1)
1 Nominal lumens based on NEMA 7×7 (Non-optic), 5000K CCT with clear glass lens.
2 Refer to catalogue pages for detailed temperature tables/operating temperature based on lumen output/certification.
| Category | ATEX Lighting (Zone 1 & Zone 2) |
|---|
| Lumens to Watts | 9,500 lumens is 175-250 W HID; 19,500 lumens is 400-750 W HID; 38,000 lumens is 1500 W HID |
| Ambient Temperature | -40 °C to +65 °C (-40 °F to +149 °F) for IAMLCL6, IAMLCL8. -40 °C to +55 °C (-40 °F to +131 °F) for high lumen IAMLCL3 output |
| Electrical | 120-277 Vac, 50/60 Hz or 125-300 Vdc | Dimmable output |
| Radio | 2.4 GHz ISM Band. WirelessHART Protocol |
| Antenna Type | External |
| Update Rate | 1 sec to 60 min, user selectable, default 5 min |
| Standard Materials | Copperfree (4/10 of 1% max.) aluminium housing; silicone rubber gaskets; zinc plated steel yoke; clear polycarbonate photocell housing; stainless steel bolts, guard and safety cable; aluminium visor and aluminium close up plugs |
| Standard Finishes | Architectural bronze polyester housing, lens cover, visor and yoke bracket |
| Warranty | 10 year standard warranty |
| Series Lumen Output | AMLCL6 | AMLCL8 | AMLCL3 |
| Nominal Wattage (W, @120 V) | 73 | 154 | 317 |
| Equivalencies (W, HID) | 175-250 | 400-750 | 1500 |
| Nominal Lumens1 | Up to 9,500 | Up to 19,500 | Up to 38,000 |
| Efficacy (up to, lm/W)1 | 141 | 128 | 126 |
| Colour Temperature (CCT) (K) | 5000/4000/3000/1800/Amber | ||
| Colour Rendering Index (CRI) | ≥ 70 CRI (5000K / 1800K) | ≥ 80 CRI (4000K / 3000K) | ≥ 56 CRI (Amber) | ||
| Voltage | 120-277 Vac, 50/60 Hz, 125-300 Vdc | ||
| Surge Protection | Standard: 6 kV/3 kA | ||
| L70 Lifetime (hrs, reported) | +25 °C (+77 °F) Ambient Temperature: Reported > 60,000 hours | Calculated > 200,000 hours +65 °C (+149 °F) Ambient Temperature: Reported > 60,000 hours | Calculated > 135,000 hours | ||
| Ambient Temperature2 | -40 °C to +65 °C (-40 °F to +149 °F) | -40 °C to +55 °C (-40 °F to +131 °F) | |
| Temperature Code2 | T3 – T6 | ||
| Fixture Weight – kg (lbs) | 10.49 kg (23.13 lbs | 17.25 kg (38.02 lbs) | |
| Replaceable Parts | Drivers, Lens, Yoke Mount Bracket | ||
Tell us your quantity and requirements — we reply within one business day.
Hazardous Area LED Luminaires – Zone 1 Zone 2 ATEX LED LightingPlease Note: Appleton™ ATX™ Linmaster™ LED Zone 2 Series replaces the FNLED Series Luminaires
Hazardous Area LED Luminaires – Zone 1 Zone 2 ATEX LED LightingPlease Note: Appleton™ ATX™ Linmaster™ LED Zone 1 Series replaces the FELED Series Luminaires
Hazardous Area LED Luminaires – Zone 1 Zone 2 ATEX LED LightingPlease Note: Appleton™ ATX™ Linmaster™ LED Zone 1 Series replaces the FELED Series Appleton ATX Linmaster™ LED Zone 2 Series replaces the FNLED Series
Share your specifications and quantities. Our team will review your request and come back with sourcing options and a quotation.