MEDC XB4 | ATEX Beacon | Hazardous Area Beacons Zone 1 & Zone 2 21 Joule Xenon Ex d

MEDC XB4 are ATEX beacons that have a high output of 21 Joule, specifically designed for use in potentially explosive atmospheres and harsh environmental conditions in ATEX & IECEx Zone 1 and…

CategoryATEX Sounders & Beacons
  • Quoted to your quantity
  • Documentation on request
  • International delivery

Product Overview

Zone 1 & Zone 2 Hazardous Areas

MEDC XB4 are ATEX beacons that have a high output of 21 Joule, specifically designed for use in potentially explosive atmospheres and harsh environmental conditions in ATEX & IECEx Zone 1 and Zone 2 hazardous areas.

The high output hazardous area Xenon beacon, with explosion protection concept Ex d, can be painted to customers specification and supplied with identification labels.

The MEDC XB4 is available with optional Exe terminal chamber.

Contact our team for customer service, competitive quotations and availability from stock for the MEDC range of sounders, including MEDC XB4, for safe use in hazardous areas with explosive atmospheres.

Medc XB4 | EX D 21 Joule Xenon Beacon

The MEDC XB4 hazardous area beacon is available in a choice of variants such as stainless steel and alloy options for ordinary locations.

  • XB4 (alloy) (Ex d)
  • XB4 (stainless) (Ex d)
  • XB4UL (alloy) (UL)
  • XB4UL (stainless steel) (UL)
  • XB4UL (alloy) (ordinary locations)
  • XB4UL (stainless steel) (ordinary locations)

Medc

The MEDC range of sounders and beacons from the Crouse Hinds series of Signalling & Alarms – a comprehensive range of Explosion Proof call points are also available with ATEX & IECEx certification and explosion protection to both Ex d (flameproof) and Ex ia (Intrinsically Safe) applications.

Features

  • Zone 1 & 2 (Gas) and Zone 21 & 22 (Dust) Hazardous Areas
  • UL Listed for USA and Canada
    • – Hazardous Locations with Explosive Atmospheres:
    • Class I, Div 1, Groups C & D.
    • Class I, Zone 1, AExd IIB T4.
    • Ordinary locations: Visual-Signal Device.
  • Exde IICT5.
  • ATEX approved Ex II 2GD.
  • BASEEFA certified.
  • TR CU certified.
  • Certified temperature: –55°C to +70°C*.
  • IP66 & IP67 Ingress Protection
  • Stainless steel or marine grade alloy.
  • Various lens colours for hazardous are beacon.
  • Twin replaceable tubes.
  • Exde version has gland earth continuity in the
  • GRP terminal chamber.
  • Tapered spigot flamepath.
  • Telephone or relay initiated option for ATEX beacon.
  • Optional lens guard.

*Depending on version.

Nominal Voltage

NOTE: The above figures (Cd) are for a clear lens @ 1Hz flash rate.

Eaton MEDC XB4 – Ordering Requirements

The following code is designed to help in selection of the correct MEDC hazardous area beacon with ATEX approval and certification.

EATON MEDC

Eaton MEDC have developed ATEX products, including ATEX Beacons, designed for harsh and hazardous area conditions and where there is a risk of explosion due to the presence of flammable gas and dust atmospheres both onshore and offshore – since 1975 MEDC have been designers and manufacturers of alarm, signal, control and communications equipment.

Complete range of LV-HV Cable Joints, Terminations, Cleats & Glands are available to support installation of power, control and instrumentation cables up to 33kV – includes Cold Shrink for use in hazardous areas to provide electrical insulation and cable protection.

Cable Cleats | Cable Lugs | Cable Transits | Cable Joints

Thermon | EXHEAT | Abtech | Marechal Electric | 3M Electrical

Technical Specifications

CategoryATEX Sounders & Beacons
Nominal voltaged.ca.c. 50/60Hz
24110240
XB4 tube energy (Joules)212121
Peak Current Consumption (mA)1400350185
Effective intensity (Cd)355355355
Peak intensity (Cd)123691123691123691
Hazardous Area Certifications
ATEX Ex dCert. no. Baseefa 04ATEX0224X. Certified to: EN60079-0, EN60079-1, EN60079-31. Ex II 2GD, Ex d IIC T4/T5/T6 Gb. Ex tb IIIC T85ºC/T100ºC/T135ºC Db.
ATEX Ex deEx II 2GD, EEx de IIC
IECEx Ex dCert. no. IECEx BAS 10.0078X. Certified to: IEC60079-0, IEC60079-1, IEC60079-31. Ex II 2GD, Ex d IIC T4/T5/T6 Gb. Ex tb IIIC T85ºC/T100ºC/T135ºC Db.
UL Haz LocsListing no. E187894. Class I, Div 1, Groups C & D. Class I, Zones 1
UL Ord LocsListing no. S8128. Visual Signal Device
CUTR Ex d1Ex II 2GD, Ex d IIC T4/T5/T6 Gb. Ex tb IIIC T85ºC/T100ºC/T135ºC Db.
INMETRO Ex dEx d IIC T4/T5/T6 Gb
INMETRO Ex deEx de IIC T4/T5/T6 Gb
Specifications
MaterialLM25TF Marine Grade Alloy body. Grade 316 ANC4B Stainless Steel body. Glass reinforced polyester (GRP) terminal chamber. Toughened Wellglass
FinishRed epoxy paint finish as standard or to customer specification
Certified temp: UL -25ºC to + 70ºC. ATEX -50ºC to +55ºC (Ex de). ATEX, IECEx, CUTR & Inmetro. -55ºC to +70ºC (Ex d).
WeightExd: 6.6kg. Exde: 7.6kg. Add 8.4kg for stainless steel version
EntriesUp to 3 x M20 or 2 x M25 ISO in Exd unit. Up to 4 x M20 or 4 x M25 ISO in Exe unit.
Telephone initiation or relay interfaceInitiation by telephone ringing tone or low voltage control signals, plus initiation of a second beacon or sounder.
TerminalsExe: 6 off suitable for up to 6sqmm cable. Exd: 8 off suitable for up to 6sqmm cable
Tube life>1×106 flashes

Request Information About This Product

Tell us your quantity and requirements — we reply within one business day.

Related Products

Have a product requirement?

Share your specifications and quantities. Our team will review your request and come back with sourcing options and a quotation.