MEDC XB13 | Hazardous Area Beacon | ATEX Beacons Zone 1 & Zone 2 Beacons 10 Joule
MEDC XB13 are listed beacons designed for use in potentially explosive atmospheres and harsh environmental conditions.
MEDC XB4 are ATEX beacons that have a high output of 21 Joule, specifically designed for use in potentially explosive atmospheres and harsh environmental conditions in ATEX & IECEx Zone 1 and…
MEDC XB4 are ATEX beacons that have a high output of 21 Joule, specifically designed for use in potentially explosive atmospheres and harsh environmental conditions in ATEX & IECEx Zone 1 and Zone 2 hazardous areas.
The high output hazardous area Xenon beacon, with explosion protection concept Ex d, can be painted to customers specification and supplied with identification labels.
The MEDC XB4 is available with optional Exe terminal chamber.
Contact our team for customer service, competitive quotations and availability from stock for the MEDC range of sounders, including MEDC XB4, for safe use in hazardous areas with explosive atmospheres.
The MEDC XB4 hazardous area beacon is available in a choice of variants such as stainless steel and alloy options for ordinary locations.
The MEDC range of sounders and beacons from the Crouse Hinds series of Signalling & Alarms – a comprehensive range of Explosion Proof call points are also available with ATEX & IECEx certification and explosion protection to both Ex d (flameproof) and Ex ia (Intrinsically Safe) applications.
*Depending on version.
NOTE: The above figures (Cd) are for a clear lens @ 1Hz flash rate.
The following code is designed to help in selection of the correct MEDC hazardous area beacon with ATEX approval and certification.
EATON MEDC
Eaton MEDC have developed ATEX products, including ATEX Beacons, designed for harsh and hazardous area conditions and where there is a risk of explosion due to the presence of flammable gas and dust atmospheres both onshore and offshore – since 1975 MEDC have been designers and manufacturers of alarm, signal, control and communications equipment.
Complete range of LV-HV Cable Joints, Terminations, Cleats & Glands are available to support installation of power, control and instrumentation cables up to 33kV – includes Cold Shrink for use in hazardous areas to provide electrical insulation and cable protection.
Cable Cleats | Cable Lugs | Cable Transits | Cable Joints
Thermon | EXHEAT | Abtech | Marechal Electric | 3M Electrical
| Category | ATEX Sounders & Beacons |
|---|
| Nominal voltage | d.c | a.c. 50/60Hz | |
| 24 | 110 | 240 | |
| XB4 tube energy (Joules) | 21 | 21 | 21 |
| Peak Current Consumption (mA) | 1400 | 350 | 185 |
| Effective intensity (Cd) | 355 | 355 | 355 |
| Peak intensity (Cd) | 123691 | 123691 | 123691 |
| Hazardous Area Certifications | |
| ATEX Ex d | Cert. no. Baseefa 04ATEX0224X. Certified to: EN60079-0, EN60079-1, EN60079-31. Ex II 2GD, Ex d IIC T4/T5/T6 Gb. Ex tb IIIC T85ºC/T100ºC/T135ºC Db. |
| ATEX Ex de | Ex II 2GD, EEx de IIC |
| IECEx Ex d | Cert. no. IECEx BAS 10.0078X. Certified to: IEC60079-0, IEC60079-1, IEC60079-31. Ex II 2GD, Ex d IIC T4/T5/T6 Gb. Ex tb IIIC T85ºC/T100ºC/T135ºC Db. |
| UL Haz Locs | Listing no. E187894. Class I, Div 1, Groups C & D. Class I, Zones 1 |
| UL Ord Locs | Listing no. S8128. Visual Signal Device |
| CUTR Ex d | 1Ex II 2GD, Ex d IIC T4/T5/T6 Gb. Ex tb IIIC T85ºC/T100ºC/T135ºC Db. |
| INMETRO Ex d | Ex d IIC T4/T5/T6 Gb |
| INMETRO Ex de | Ex de IIC T4/T5/T6 Gb |
| Specifications | |
| Material | LM25TF Marine Grade Alloy body. Grade 316 ANC4B Stainless Steel body. Glass reinforced polyester (GRP) terminal chamber. Toughened Wellglass |
| Finish | Red epoxy paint finish as standard or to customer specification |
| Certified temp | : UL -25ºC to + 70ºC. ATEX -50ºC to +55ºC (Ex de). ATEX, IECEx, CUTR & Inmetro. -55ºC to +70ºC (Ex d). |
| Weight | Exd: 6.6kg. Exde: 7.6kg. Add 8.4kg for stainless steel version |
| Entries | Up to 3 x M20 or 2 x M25 ISO in Exd unit. Up to 4 x M20 or 4 x M25 ISO in Exe unit. |
| Telephone initiation or relay interface | Initiation by telephone ringing tone or low voltage control signals, plus initiation of a second beacon or sounder. |
| Terminals | Exe: 6 off suitable for up to 6sqmm cable. Exd: 8 off suitable for up to 6sqmm cable |
| Tube life | >1×106 flashes |
Tell us your quantity and requirements — we reply within one business day.
MEDC XB13 are listed beacons designed for use in potentially explosive atmospheres and harsh environmental conditions.
MEDC XB16 are listed beacons designed for use in potentially explosive atmospheres and harsh environmental conditions.
MEDC XB10 compact and lightweight 10 & 15 Joule ATEX beacons that have been designed for use in potentially explosive atmospheres and harsh environmental conditions in ATEX & IECEx Zone 1 and…
Share your specifications and quantities. Our team will review your request and come back with sourcing options and a quotation.