MEDC XB12 | ATEX Beacon | Hazardous Area Beacons Zone 1 & Zone 2 21 Joule Xenon Ex d

MEDC XB12 are ATEX beacons that have a high output (21 Joule) specifically designed for use in potentially explosive atmospheres and harsh environmental conditions in ATEX & IECEx Zone 1 and Zone…

CategoryATEX Sounders & Beacons
  • Quoted to your quantity
  • Documentation on request
  • International delivery

Product Overview

ATEX Beacons Zone 1 & Zone 2

MEDC XB12 are ATEX beacons that have a high output (21 Joule) specifically designed for use in potentially explosive atmospheres and harsh environmental conditions in ATEX & IECEx Zone 1 and Zone 2 hazardous areas.

The XB12 ATEX beacon housing is manufactured completely from a UV stable, glass reinforced polyester

The high output hazardous area Xenon beacon with explosion protection concept Ex d can be painted to customer specification and supplied with identification labels.

Contact our team for customer service, competitive quotations and availability from stock for the MEDC range of sounders, including MEDC XB12, for safe use in hazardous areas with explosive atmospheres.

Medc XB12 | EX D 21 Joule Xenon Beacon

The MEDC XB12 hazardous area beacon is available in a choice of variants with mounting options for weatherproof and ordinary locations.

  • XB12 (Ex d)
  • XB12UL (UL)
  • XB12UM (UL marine)
  • XB12UW (ordinary locations)
  • XB12W (weatherproof only

Medc

The MEDC range of sounders and beacons from the Crouse Hinds series of Signalling & Alarms – a comprehensive range of Explosion Proof call points are also available with ATEX & IECEx certification and explosion protection to both Ex d (flameproof) and Ex ia (Intrinsically Safe) applications.

Features

  • Zone 1 & 2 (Gas) and Zone 21 & 22 (Dust) Hazardous Areas
  • UL Listed for USA and Canada
    • – Hazardous Locations with Explosive Atmospheres:
    • Class I, Div 2, Groups C & D.
    • Class I, Zones 1 & 2, Exd IIB T4 & T5.
    • Ordinary locations: Visual-Signal Device.
    • Marine Listed
  • Explosion Protection | Exd, IIB T4 & T5.
  • ATEX approved, Ex II 2G.
  • BASEEFA certified.
  • TR CU certified.
  • Chinese (CQST) certified.
  • Inmetro certified.
  • High Output (21 Joules).
  • IP66 & IP67 Ingress Protection
  • Certified temperature: –55°C to +70°C.
  • Corrosion resistant GRP.
  • Optional stainless steel backstrap.
  • Various lens colours for hazardous are beacons
  • Optional lens guard.
  • Optional telephone initiation.
  • Twin replaceable tubes available for ATEX beacons

Nominal Voltage

NOTE: The above figures (Cd) are for a clear lens @ 1Hz flash rate.

Eaton MEDC XB12 – Ordering Requirements

The following code is designed to help in selection of the correct MEDC hazardous area beacon with ATEX approval and certification.

EATON MEDC

Eaton MEDC have developed ATEX products, including ATEX Beacons, designed for harsh and hazardous area conditions and where there is a risk of explosion due to the presence of flammable gas and dust atmospheres both onshore and offshore – since 1975 MEDC have been designers and manufacturers of alarm, signal, control and communications equipment.

Complete range of LV-HV Cable Joints, Terminations, Cleats & Glands are available to support installation of power, control and instrumentation cables up to 33kV – includes Cold Shrink for use in hazardous areas to provide electrical insulation and cable protection.

Cable Cleats | Cable Lugs | Cable Transits | Cable Joints

Thermon | EXHEAT | Abtech | Marechal Electric | 3M Electrical

Technical Specifications

CategoryATEX Sounders & Beacons
Nominal voltaged.ca.c. 50/60Hz
24110240
XB12 tube energy (Joules)212121
Peak Current Consumption (mA)1400350185
Effective intensity (Cd)355355355
Peak intensity (Cd)123691123691123691
Power Consumption (Watts)33.638.544.4
Hazardous Area Certifications
ATEX Ex dCert. no. BAS99ATEX2196. Certified to: EN60079-0, EN60079-1. Ex II 2G, Ex d IIB T4/T5/T6 Gb.
IECEx Ex dCert. no. IECEx BAS 10.0094. Certified to: IEC60079-0, IEC60079-1. Ex d IIB T4/T5/T6 Gb.
UL Haz LocsListing no. E187894. Class I, Div 2, Groups C & D.
UL Ord LocsListing no. S8128. Visual Signal Device.
CUTR Ex d1Ex d IIB T4/T5/T6 Gb.
INMETRO Ex dEx d IIB T4/T5/T6 Gb.
CQSTEx d IIB T4/T5
Specifications
MaterialBody: Glass reinforced polyester. Lens: Toughened Glass. Cover Screws + Backstrap: Stainless steel 316.
FinishRed epoxy paint finish as standard or to customer specification
Certified tempExd -55ºC to +70ºC (T4). -55ºC to +55ºC (T5). -55ºC to +40ºC (T6). UL -55ºC to +70ºC (Hazardous Locations). -55ºC to +55ºC (Ordinary Locations)..
Weight7.0kg
Ingress ProtectionIP66 & 67
Fire RetardancyGRP is fire retardant to ISO 1210
Earth ContinuityOptional for metal glands provided via a brass plate (not available in UL version).
Entries2 x M20 ISO EExd. 2 x 1/2″ NPT UL.
Telephone initiationInitiation by telephone ringing tone.
Terminals6 x 6.0sqmm
Tube life>1×106 flashes
LabelsDuty/Tag Label optional.

Request Information About This Product

Tell us your quantity and requirements — we reply within one business day.

Related Products

Have a product requirement?

Share your specifications and quantities. Our team will review your request and come back with sourcing options and a quotation.