MEDC XB8 | Hazardous Area Beacon | ATEX Beacons Zone 1 & Zone 2 0.5 Joule Intrinsically Safe Ex ia

MEDC XB8 are ATEX beacons that are rugged, intrinsically safe and weatherproof intended for potentially Explosive Atmospheres in ATEX & IECEx Zone 1 and Zone 2 hazardous areas.

CategoryATEX Sounders & Beacons
  • Quoted to your quantity
  • Documentation on request
  • International delivery

Product Overview

Zone 1 & Zone 2 Hazardous Areas

MEDC XB8 are ATEX beacons that are rugged, intrinsically safe and weatherproof intended for potentially Explosive Atmospheres in ATEX & IECEx Zone 1 and Zone 2 hazardous areas.

The ATEX beacon is available in 12V and 24V versions and for gas groups IIB or IIC.

The ATEX beacon with explosion protection concept Ex d is also available as a non-hazardous version at a lower cost.

MEDC XB8 | Ex iA 0.5 Joule Beacon

The MEDC XB8 hazardous area beacon is available in a choice of intrinsically safe and weatherproof variants.

  • XB8 12V IIB (Ex ia)
  • XB8 12V IIC (Ex ia)
  • XB8 24V IIB (Ex ia)
  • XB8 24V IIC (Ex ia)

Medc

The MEDC range of sounders and beacons from the Crouse Hinds series of Signalling & Alarms – a comprehensive range of Explosion Proof call points are also available with ATEX & IECEx certification and explosion protection to both Ex d (flameproof) and Ex ia (Intrinsically Safe) applications.

Features

  • Hazardous area beacon certified for Zones 0, 1, 2 & safe area use.
  • Explosion Protection | Ex ia IIB/IIC T4.
  • ATEX approved, Ex II 1G.
  • BASEEFA certified.
  • TR CU certified.
  • IP66 & IP67 Ingress Protection
  • Certified temperature: –55°C to +60°C.
  • Corrosion resistant GRP body.
  • High intensity flash.
  • Clear polycarbonate lens on ATEX beacons.
  • Retained stainless steel cover screws.
  • Encapsulated electronics.

Eaton MEDC XB8 – Ordering Requirements

The following code is designed to help in selection of the correct MEDC hazardous area beacon with ATEX approval and certification.

Eaton MEDC

Eaton MEDC have developed ATEX products, including ATEX Beacons, designed for harsh and hazardous area conditions and where there is a risk of explosion due to the presence of flammable gas and dust atmospheres both onshore and offshore – since 1975 MEDC have been designers and manufacturers of alarm, signal, control and communications equipment.

Complete range of LV-HV Cable Joints, Terminations, Cleats & Glands are available to support installation of power, control and instrumentation cables up to 33kV – includes Cold Shrink for use in hazardous areas to provide electrical insulation and cable protection.

Thermon | EXHEAT | Abtech | Marechal Electric | 3M Electrical

Technical Specifications

CategoryATEX Sounders & Beacons
Hazardous Area Certifications
ATEX Ex iaCert. no. BAS00ATEX1258X Certified to: EN60079-0, EN60079-11 Ex II 1G, Ex ia IIB/IIC T4 Ga. System cert. no. Baseefa13Y0230
IECEx Ex iaCert. no. IECEx BAS 10.0111X Certified to: IEC60079-0, IEC60079-11 Ex ia IIB/IIC T4 Ga
TR CU Ex ia0Ex ia IIB/IIC T4 Ga Russian Fire Approved
ABSAmerican Bureau of Shipping Type Approval
Specifications
MaterialUV stable glass reinforced polyester body Clear polycarbonate cover/lens Retained stainless steel cover screws
FinishPainted red as standard or to customer specification
Tube energyIIB version 0.5 Joules IIC version 0.4 Joules
Weight1.4 kg
Certified temp–55ºC to +60ºC
Ingress protectionIP66 & IP67
Tube life>1 x 106 flashes
Voltage12V or 24V via suitable barrier
Current consumption24V IIB model – 71mA max. nominal 24V IIC model – 55mA max. nominal 12V IIB & IIC models – 52mA max. nominal
Tube typeXenon discharge
Lens colourClear as standard. Coloured options available
Terminals8 x 2.5sqmm
Flash rate1 flash per second
LabelsDuty and tag labels optional
Cable entriesUp to 3 x M20 via knockouts

Request Information About This Product

Tell us your quantity and requirements — we reply within one business day.

Related Products

Have a product requirement?

Share your specifications and quantities. Our team will review your request and come back with sourcing options and a quotation.