MEDC XB13 | Hazardous Area Beacon | ATEX Beacons Zone 1 & Zone 2 Beacons 10 Joule
MEDC XB13 are listed beacons designed for use in potentially explosive atmospheres and harsh environmental conditions.
Models: FB11 / FL11
Models: FB11 / FL11
REQUEST A QUOTE
Certification, temperature classification and hazardous area suitability vary by model and configuration.
The MEDC FB11 and FL11 are steady visual signalling devices designed for potentially explosive gas and dust atmospheres and harsh environmental conditions.
The FB11 uses a filament lamp, while the FL11 uses fluorescent lighting. Both models are housed in UV-stable glass-reinforced polyester, providing a lightweight and corrosion-resistant enclosure suitable for demanding onshore and offshore installations.
Available configurations include Ex db flameproof—commonly described as Ex d—and weatherproof versions. The precise certification, operating temperature, voltage and lamp arrangement depend on the selected model.
The FB11 and FL11 can be supplied with different lens colours, mounting arrangements, cable entries, finishes and accessories to meet project-specific signalling requirements.
Explore the complete range of ATEX beacons for Zone 1 and Zone 2 hazardous areas.
SEE TECHNICAL SPECIFICATIONS
GO TO DOWNLOADS
Product Overview
FB11 Filament Beacon
FL11 Fluorescent Beacon
Features
Certification
Temperature Ratings
Technical Specifications
Ordering Requirements
Downloads
Related MEDC Beacons
The Eaton MEDC FB11 and FL11 provide continuous visual indication for hazardous area alarm, warning and equipment-status applications.
Both variants use a compact cylindrical enclosure manufactured from UV-stable glass-reinforced polyester. The cover incorporates a glass lens and is secured using stainless-steel screws. An optional protective guard and mounting backstrap are available.
The GRP construction combines low weight with corrosion resistance, supporting installation in demanding onshore, offshore, marine and industrial environments.
Available options include multiple voltages, lens colours, enclosure finishes, mounting arrangements, identification labels and earth-continuity accessories.
The MEDC FB11 beacon uses a 10W filament lamp with an SBC lamp holder to provide a continuous visual signal.
Available voltage configurations include 24V DC, 48V DC and selected AC supplies from 110V to 254V. The exact voltage, certification and temperature classification must be confirmed when ordering.
Selected FB11 versions are available for ATEX and IECEx applications, weatherproof installations and North American hazardous-location requirements.
The MEDC FL11 beacon uses a fluorescent light source to provide steady visual indication.
A 5W fluorescent arrangement is available for selected 24V DC configurations, providing a nominal light output of 250 lumens. A 10W fluorescent arrangement is available for selected 240V AC configurations, providing a nominal light output of 600 lumens.
The certified ambient range can extend below the published operating range. Product selection should therefore be based on the complete ordered configuration, current certification and manufacturer operating instructions.
✔ Steady visual signalling for hazardous area applications
✔ FB11 filament and FL11 fluorescent versions
✔ Certified configurations for Zones 1, 2, 21 and 22
✔ Ex db flameproof protection
✔ ATEX and IECEx-certified options
✔ IP66 and IP67 ingress protection
✔ UV-stable glass-reinforced polyester body
✔ Glass lens
✔ Stainless-steel cover screws and optional backstrap
✔ Lightweight and corrosion-resistant construction
✔ Suitable for demanding onshore and offshore environments
✔ Multiple AC and DC voltage options
✔ Clear, red, blue, green, yellow and amber lens options
✔ Natural black or customer-specified painted finish
✔ Optional stainless-steel lens guard
✔ Optional duty and identification labels
✔ Optional earth-continuity plate for metal cable glands
The FB11 and FL11 are available with hazardous area certification for explosive gas and combustible-dust atmospheres. The applicable marking depends on the selected lamp, voltage, temperature classification and product configuration.
When installed in a dust atmosphere, certified cable-entry devices and stopping plugs must maintain the IP6X integrity of the enclosure.
The equipment is also subject to a potential electrostatic charging hazard. Installation and maintenance must follow the manufacturer’s instructions.
The permitted ambient temperature depends on the model, lamp power and required temperature class. The values below relate to certified configurations; the manufacturer’s published operating range and product instructions must also be observed.
Eaton’s product overview states an FL11 operating range of –20°C to +70°C. Do not specify operation below –20°C without confirming the exact product configuration and current manufacturer documentation.
The complete product reference is built from the required model, certification, voltage, lamp wattage, lens colour, lens guard, mounting arrangement, earth-continuity option, label and enclosure finish.
Provide the following information when requesting a quotation:
Contact our team
Download the product datasheet for dimensions, voltage options, lamp arrangements and ordering requirements. The current ATEX certificate should be checked for the latest certified construction and marking.
Technical data and certification can be revised. Confirm the current product documentation and marking when placing an order.
Alternative visual signalling products are available where a larger steady beacon, LED operation or xenon flash is required.
MEDC FB12 & FL12 Steady Beacons
MEDC LD15 LED Beacon
MEDC XB15 Xenon Beacon
Eaton FHF dSLB20 LED Signal Light
Explore the wider Eaton MEDC hazardous area signalling range.
Contact our team with the required model, certification, voltage, lens colour, mounting arrangement, temperature class and installation conditions.
Request a Quotation
| Category | ATEX Sounders & Beacons |
|---|
| ATEX Certificate | BAS99ATEX2195X, Issue 10 |
| ATEX Gas Marking | II 2 GD, Ex db IIB, temperature class and ambient range model dependent |
| ATEX Dust Marking | Ex tb IIIC, maximum surface temperature model dependent, IP66/IP67 |
| IECEx Certificate | IECEx BAS 10.0101 |
| Hazardous Area Zones | Certified configurations for Zones 1, 2, 21 and 22 |
| North American Approval | Selected FB11 configurations; certification and availability must be confirmed |
| Model | Lamp Power | Temperature Class | Temperature Marking | Certified Ambient Range |
|---|---|---|---|---|
| FB11 | 10W | T4 | T110°C | –55°C to +70°C |
| T5 | T85°C | –55°C to +55°C | ||
| T6 | T70°C | –55°C to +40°C | ||
| FL11 | 10W | T4 | T110°C | –55°C to +70°C |
| T5 | T85°C | –55°C to +55°C | ||
| T6 | T70°C | –55°C to +40°C | ||
| FL11 | 5W | T5 | T85°C | –55°C to +70°C |
| T6 | T70°C | –55°C to +55°C |
| Models | FB11 filament steady beacon; FL11 fluorescent steady beacon |
| Protection Concept | Ex db flameproof, commonly described as Ex d |
| Body Material | UV-stable glass-reinforced polyester |
| Lens | Glass |
| Cover Screws and Backstrap | Stainless steel |
| Finish | Natural black or painted to customer specification |
| FB11 Light Source | 10W filament lamp; SBC lamp holder |
| FL11 24V DC Light Source | 5W fluorescent lamp; approximately 250 lumens; G23 lamp holder |
| FL11 240V AC Light Source | 10W fluorescent lamp; approximately 600 lumens; G23 lamp holder |
| FB11 Voltage Options | 24V DC, 48V DC, 110V AC, 120V AC, 220V AC, 240V AC and 254V AC, model dependent |
| FL11 Voltage Options | 24V DC and 240V AC, model dependent |
| Approximate Weight | 2.8kg |
| Ingress Protection | IP66 and IP67 |
| Cable Entries | 2 × M20; selected UL variants use 2 × ½-inch NPT |
| Terminals | FL11 AC: 4 × 2.5mm²; FL11 DC and FB11: 6 × 2.5mm² |
| Lens Colours | Clear, red, blue, green, yellow and amber |
| Mounting | Direct mounting with or without optional backstrap |
| Lens Guard | Optional |
| Labels | Optional duty or identification label |
| Earth Continuity | Optional brass continuity plate for metal cable glands |
| Fire Retardancy | GRP fire retardant to ISO 1210 |
Tell us your quantity and requirements — we reply within one business day.
MEDC XB13 are listed beacons designed for use in potentially explosive atmospheres and harsh environmental conditions.
MEDC XB16 are listed beacons designed for use in potentially explosive atmospheres and harsh environmental conditions.
MEDC XB10 compact and lightweight 10 & 15 Joule ATEX beacons that have been designed for use in potentially explosive atmospheres and harsh environmental conditions in ATEX & IECEx Zone 1 and…
Share your specifications and quantities. Our team will review your request and come back with sourcing options and a quotation.