Product Overview

MEDC FB11 & FL11 Steady Beacon Range

Models: FB11 / FL11

REQUEST A QUOTE

Certification, temperature classification and hazardous area suitability vary by model and configuration.

The MEDC FB11 and FL11 are steady visual signalling devices designed for potentially explosive gas and dust atmospheres and harsh environmental conditions.

The FB11 uses a filament lamp, while the FL11 uses fluorescent lighting. Both models are housed in UV-stable glass-reinforced polyester, providing a lightweight and corrosion-resistant enclosure suitable for demanding onshore and offshore installations.

Available configurations include Ex db flameproof—commonly described as Ex d—and weatherproof versions. The precise certification, operating temperature, voltage and lamp arrangement depend on the selected model.

The FB11 and FL11 can be supplied with different lens colours, mounting arrangements, cable entries, finishes and accessories to meet project-specific signalling requirements.

Explore the complete range of ATEX beacons for Zone 1 and Zone 2 hazardous areas.

SEE TECHNICAL SPECIFICATIONS

GO TO DOWNLOADS

Product Overview

FB11 Filament Beacon

FL11 Fluorescent Beacon

Features

Certification

Temperature Ratings

Technical Specifications

Ordering Requirements

Downloads

Related MEDC Beacons

MEDC FB11 & FL11 Steady Beacon Range

The Eaton MEDC FB11 and FL11 provide continuous visual indication for hazardous area alarm, warning and equipment-status applications.

Both variants use a compact cylindrical enclosure manufactured from UV-stable glass-reinforced polyester. The cover incorporates a glass lens and is secured using stainless-steel screws. An optional protective guard and mounting backstrap are available.

The GRP construction combines low weight with corrosion resistance, supporting installation in demanding onshore, offshore, marine and industrial environments.

Available options include multiple voltages, lens colours, enclosure finishes, mounting arrangements, identification labels and earth-continuity accessories.

MEDC FB11 Filament Beacon

The MEDC FB11 beacon uses a 10W filament lamp with an SBC lamp holder to provide a continuous visual signal.

Available voltage configurations include 24V DC, 48V DC and selected AC supplies from 110V to 254V. The exact voltage, certification and temperature classification must be confirmed when ordering.

Selected FB11 versions are available for ATEX and IECEx applications, weatherproof installations and North American hazardous-location requirements.

MEDC FL11 Fluorescent Beacon

The MEDC FL11 beacon uses a fluorescent light source to provide steady visual indication.

A 5W fluorescent arrangement is available for selected 24V DC configurations, providing a nominal light output of 250 lumens. A 10W fluorescent arrangement is available for selected 240V AC configurations, providing a nominal light output of 600 lumens.

The certified ambient range can extend below the published operating range. Product selection should therefore be based on the complete ordered configuration, current certification and manufacturer operating instructions.

FB11 and FL11 Features

✔ Steady visual signalling for hazardous area applications

✔ FB11 filament and FL11 fluorescent versions

✔ Certified configurations for Zones 1, 2, 21 and 22

✔ Ex db flameproof protection

✔ ATEX and IECEx-certified options

✔ IP66 and IP67 ingress protection

✔ UV-stable glass-reinforced polyester body

✔ Glass lens

✔ Stainless-steel cover screws and optional backstrap

✔ Lightweight and corrosion-resistant construction

✔ Suitable for demanding onshore and offshore environments

✔ Multiple AC and DC voltage options

✔ Clear, red, blue, green, yellow and amber lens options

✔ Natural black or customer-specified painted finish

✔ Optional stainless-steel lens guard

✔ Optional duty and identification labels

✔ Optional earth-continuity plate for metal cable glands

Hazardous Area Certification

The FB11 and FL11 are available with hazardous area certification for explosive gas and combustible-dust atmospheres. The applicable marking depends on the selected lamp, voltage, temperature classification and product configuration.

When installed in a dust atmosphere, certified cable-entry devices and stopping plugs must maintain the IP6X integrity of the enclosure.

The equipment is also subject to a potential electrostatic charging hazard. Installation and maintenance must follow the manufacturer’s instructions.

Temperature Ratings

The permitted ambient temperature depends on the model, lamp power and required temperature class. The values below relate to certified configurations; the manufacturer’s published operating range and product instructions must also be observed.

Eaton’s product overview states an FL11 operating range of –20°C to +70°C. Do not specify operation below –20°C without confirming the exact product configuration and current manufacturer documentation.

Eaton MEDC FB11 & FL11 Ordering Requirements

The complete product reference is built from the required model, certification, voltage, lamp wattage, lens colour, lens guard, mounting arrangement, earth-continuity option, label and enclosure finish.

Provide the following information when requesting a quotation:

  • FB11 filament or FL11 fluorescent model
  • Required certification and destination market
  • Operating voltage
  • Lamp wattage
  • Lens colour
  • Lens guard requirement
  • Direct mounting or optional backstrap
  • Earth-continuity requirement
  • Duty or identification label wording
  • Natural black, standard colour or special finish
  • Cable-entry thread
  • Hazardous area zone and gas or dust group
  • Required temperature class
  • Minimum and maximum ambient temperature

FB11 & FL11 Product Selection Support

Contact our team

MEDC FB11 & FL11 Downloads

Download the product datasheet for dimensions, voltage options, lamp arrangements and ordering requirements. The current ATEX certificate should be checked for the latest certified construction and marking.

Technical data and certification can be revised. Confirm the current product documentation and marking when placing an order.

Alternative visual signalling products are available where a larger steady beacon, LED operation or xenon flash is required.

MEDC FB12 & FL12 Steady Beacons

MEDC LD15 LED Beacon

MEDC XB15 Xenon Beacon

Eaton FHF dSLB20 LED Signal Light

Eaton MEDC Hazardous Area Signalling

Explore the wider Eaton MEDC hazardous area signalling range.

Request an MEDC FB11 or FL11 Quotation

Contact our team with the required model, certification, voltage, lens colour, mounting arrangement, temperature class and installation conditions.

Request a Quotation

Technical Specifications

CategoryATEX Sounders & Beacons
ATEX CertificateBAS99ATEX2195X, Issue 10
ATEX Gas MarkingII 2 GD, Ex db IIB, temperature class and ambient range model dependent
ATEX Dust MarkingEx tb IIIC, maximum surface temperature model dependent, IP66/IP67
IECEx CertificateIECEx BAS 10.0101
Hazardous Area ZonesCertified configurations for Zones 1, 2, 21 and 22
North American ApprovalSelected FB11 configurations; certification and availability must be confirmed
ModelLamp PowerTemperature ClassTemperature MarkingCertified Ambient Range
FB1110WT4T110°C–55°C to +70°C
T5T85°C–55°C to +55°C
T6T70°C–55°C to +40°C
FL1110WT4T110°C–55°C to +70°C
T5T85°C–55°C to +55°C
T6T70°C–55°C to +40°C
FL115WT5T85°C–55°C to +70°C
T6T70°C–55°C to +55°C
ModelsFB11 filament steady beacon; FL11 fluorescent steady beacon
Protection ConceptEx db flameproof, commonly described as Ex d
Body MaterialUV-stable glass-reinforced polyester
LensGlass
Cover Screws and BackstrapStainless steel
FinishNatural black or painted to customer specification
FB11 Light Source10W filament lamp; SBC lamp holder
FL11 24V DC Light Source5W fluorescent lamp; approximately 250 lumens; G23 lamp holder
FL11 240V AC Light Source10W fluorescent lamp; approximately 600 lumens; G23 lamp holder
FB11 Voltage Options24V DC, 48V DC, 110V AC, 120V AC, 220V AC, 240V AC and 254V AC, model dependent
FL11 Voltage Options24V DC and 240V AC, model dependent
Approximate Weight2.8kg
Ingress ProtectionIP66 and IP67
Cable Entries2 × M20; selected UL variants use 2 × ½-inch NPT
TerminalsFL11 AC: 4 × 2.5mm²; FL11 DC and FB11: 6 × 2.5mm²
Lens ColoursClear, red, blue, green, yellow and amber
MountingDirect mounting with or without optional backstrap
Lens GuardOptional
LabelsOptional duty or identification label
Earth ContinuityOptional brass continuity plate for metal cable glands
Fire RetardancyGRP fire retardant to ISO 1210

Request Information About This Product