MEDC XB13 | Hazardous Area Beacon | ATEX Beacons Zone 1 & Zone 2 Beacons 10 Joule
MEDC XB13 are listed beacons designed for use in potentially explosive atmospheres and harsh environmental conditions.
MEDC FB12 & FL12 are ATEX beacons that have been designed for use in potentially explosive atmospheres and harsh environmental conditions in ATEX & IECEx Zone 1 and Zone 2 hazardous areas.…
MEDC FB12 & FL12 are ATEX beacons that have been designed for use in potentially explosive atmospheres and harsh environmental conditions in ATEX & IECEx Zone 1 and Zone 2 hazardous areas. The enclosures are suitable for use offshore or onshore, where light weight combined with corrosion resistance is required.
The hazardous area beacon housing is manufactured completely from a UV stable, glass reinforced polyester. Stainless steel screws and mounting bracket are available ensuring a totally corrosion free product.
Contact our team for customer service, competitive quotations and availability from stock for the MEDC range of sounders, including MEDC FB12 / FL12, for safe use in hazardous areas with explosive atmospheres.
The MEDC FB12 hazardous area beacon is available in a choice of variants with mounting options for weatherproof and ordinary locations.
The MEDC FL12 hazardous area beacon is available in a choice of variants with mounting options for weatherproof and ordinary locations.
The MEDC range of sounders and beacons from the Crouse Hinds series of Signalling & Alarms – a comprehensive range of Explosion Proof call points are also available with ATEX & IECEx certification and explosion protection to both Ex d (flameproof) and Ex ia (Intrinsically Safe) applications.
*Model dependent.
The following code is designed to help in selection of the correct MEDC hazardous area beacon with ATEX approval and certification.
Eaton MEDC
Eaton MEDC have developed ATEX products, including ATEX Beacons, designed for harsh and hazardous area conditions and where there is a risk of explosion due to the presence of flammable gas and dust atmospheres both onshore and offshore – since 1975 MEDC have been designers and manufacturers of alarm, signal, control and communications equipment.
Complete range of LV-HV Cable Joints, Terminations, Cleats & Glands are available to support installation of power, control and instrumentation cables up to 33kV – includes Cold Shrink for use in hazardous areas to provide electrical insulation and cable protection.
Thermon | EXHEAT | Abtech | Marechal Electric | 3M Electrical
| Category | ATEX Sounders & Beacons |
|---|
| Eaton MEDC Part Number | Wattage | T Class | Min.Amb | Max.Amb |
| FB11 | All | T4 | -55ºC | +70ºC |
| T5 | -55ºC | +55ºC | ||
| T6 | -55ºC | +40ºC | ||
| FL11 | All | T4 | -20ºC | +70ºC |
| T5 | -20ºC | +55ºC | ||
| T6 | -20ºC | +40ºC | ||
| FB12 | 100 | T3 | -55ºC | +20ºC |
| 60 | T4 | -55ºC | +55ºC | |
| T5 | -55ºC | +30ºC | ||
| FL12 | 39 | T4 | -20ºC | +40ºC |
| T5 | -20ºC | +70ºC | ||
| 26 | T4 | -20ºC | +70ºC | |
| T5 | -20ºC | +55ºC | ||
| T6 | -20ºC | +40ºC | ||
| 13 | T4 | -20ºC | +70ºC | |
| T5 | -20ºC | +55ºC | ||
| T6 | -20ºC | +40ºC |
| Models | FL11 & FL12 – Fluorescent, Exd. FB11 & FB12 – Filament, Exd. FB12 – Filament, Exd & UL Listed. |
| Hazardous Area Certifications | |
| FB11/FL11 ATEX Ex d | Cert. no. BAS99ATEX2195. Certified to: EN60079-0, EN60079-1, EN60079-31. Ex II 2GD, Ex d IIB T4/T5/T6 Gb, Ex tb IIIC T70ºC/T85ºC/T110ºC Db. |
| FB11/FL11 IECEx Ex d | Cert. no. IECEx BAS 10.0101. Certified to: IEC60079-0, IEC60079-1, IEC60079-31. Ex d IIB T4/T5/T6 Gb, Ex tb IIIC 70ºC/85ºC/110ºC Db |
| FB12/FL12 ATEX Ex d | Cert. no. BAS99ATEX2196. Certified to: EN60079-0, EN60079-1. Ex II 2G, Ex d IIB T3/T4/T5/T6 Gb.* |
| FB11/FL11 IECEx Ex d | Cert. no. IECEx BAS 10.0094. Certified to: IEC60079-0, IEC60079-1. Ex d IIB T3/T4/T5/T6 Gb.* |
| FB11/FB12 UL | Listing no. E187814. Class I, Div 2, Groups C & D. Class I, Zones 1, AExd IIB T4/T5. |
| FB11/FL11 CUTR Ex d | 1Ex d IIB T4/T5/T6 Gb, Ex tb IIIC 70ºC/85ºC/110ºC Db. |
| FB12/FL12 CUTR Ex d | 1Ex d IIB T3/T4/T5/T6 Gb.* |
| Inmetro Ex d | Ex d IIB T3/T4/T5/T6 Gb. *Model dependent. |
| Specifications | |
| Material | Body: Glass reinforced polyester (GRP). Lens: Glass. Cover Screws + Backstrap: Stainless steel 316. |
| Finish | Natural black or painted to customer specification |
| Voltage | FL11 & FL12 – 24V d.c., 240V a.c. FB11 & FB12 – 24V d.c., 48V d.c. – 110V a.c., 120V a.c.,220V a.c., 240V a.c., 254V a.c. |
| Filament | FB11 – 10W filament fitted as standard – (SBC lamp holder). FB12 – 60W or 100W single filament fitted as standard. Others may be available (UL Listed – 60W only) – (ES27 lamp holder). |
| Fluorescent | 5 Watt type light output 250 Lumens (FL11 24V d.c. version only) – G23 lamp holder. 10 Watt type light output 600 Lumens (FL11 240V a.c. version only) – G23 lamp holder. 13 Watt type light output 900 Lumens (FL12, per tube) – G24Q-1 lamp holder |
| Certified Temp | FB11 & FB12, EExd = –55ºC to + 70ºC*. FL11 & FL12, EExd = –55ºC to + 70ºC*. *Model dependent – see table for details. * Operating temp is –20ºC |
| Weight | FL11, FB11 – 2.8 kg*. FL12 – 7.2 kg*. FB12 – 7.6 kg*. *Model dependent |
| Terminals | FL (a.c.) 4 x 2.5sqmm FL11 (d.c.), FB11 6 x 2.5sqmm FB12/FL12 6 x 6.0sqmm FB12 UL 6 x 10 AWG |
| Ingress Protection | IP66 and IP67 |
| Entries | 2 x M20 ISO EExd. 2 x 1/2“ NPT UL Listed. |
| Labels | Duty/Tag Label optional. |
| Fire Retardancy | GRP is fire retardant to ISO 1210 |
| Earth Continuity | Optional for metal glands provided via a brass plate |
Tell us your quantity and requirements — we reply within one business day.
MEDC XB13 are listed beacons designed for use in potentially explosive atmospheres and harsh environmental conditions.
MEDC XB16 are listed beacons designed for use in potentially explosive atmospheres and harsh environmental conditions.
MEDC XB10 compact and lightweight 10 & 15 Joule ATEX beacons that have been designed for use in potentially explosive atmospheres and harsh environmental conditions in ATEX & IECEx Zone 1 and…
Share your specifications and quantities. Our team will review your request and come back with sourcing options and a quotation.