ATEX Heat Tracing | Hazardous Area Zones 1 & 2 (21 & 22)ATEX Heat Tracing | Eltherm ELSR-N-40-2-BO Self Regulating Heating Cable
Eltherm ELSR-N-40-2-BO Self-Regulating Heating Cable

ATEX Heat Tracing Cable | Eltherm ELSR-SHH
ATEX Heat Tracing Cable | Eltherm ELSR-SHH
The Eltherm ELSR-SHH high temperature self-regulating heat tracing cables is designed for temperature maintenance in industrial processes and applications in hazardous areas – and is suitable for use up to 250 °C . The high chemical resistance allows the cables to be installed in environments with exposure to aggressive influences. With IECEx and ATEX Certification, Eltherm ELSR-SHH Heat Tracing cables are suitable for Zone 1 and Zone 2 hazardous areas – and have a temperature Class of T3/T2.
The ELSR-SHH is now available with certificate according to standard EN 60079-30-1:2017 .
The self-regulating trace heating cable provides frost protection and temperature maintenance to pipework, silos vessels ,tanks, valves and pumps. Suitable for use in the following industries:
Our Team of Trained Sales Engineers are available to advise and support your ATEX heat tracing enquiries – this includes design and supply of complex multi-kilometre, major-project systems to custom heat trace cable kits for the protection of winterisation against plant and factory facilities.
Eltherm ELSR-SHH Heater Cable wattages per metre at 10°C – 15, 30, 45, 60 and 75 watts.
Eltherm ELSR-SH self-regulating heater cables has a BOT cable design which has a high chemical resistance and is able to withstand aggressive chemicals, oil and fuel for improved service life due to the protective braid and fluoropolymer outer jacket.
The ELSR-SHH hazardous area heat tracing cable has both ATEX and IECEx approvals suitable for use in Zone 1 and Zone 2 hazardous areas.
Heat Tracing Classification:
System Classification:
Hazardous Area Certification:
Temperature Class: T3
*Except for 75 W/m: T2
The Eltherm ELSR-SHH high temperature heat tracing range is designed for temperature maintenance in industrial processes and applications in hazardous areas. The heat tracer’s high chemical resistance allows them to be installed in environments with exposure to aggressive influences.
Contact our team for technical guidance, heat loss calculations for pipework systems and optimum specification of the correct heat tracer cable for your application.
*1 Heating circuit lengths on the following conditions:
A Trace Heater
B Power Connection Kit
C End Termination Kit
D Junction Box
E Pipe Mounting Bracket
F Fasteners and Self-adhesive Tapes, Foils
G Insulation Bushing
H Warning Sign
I Temperature Controller
J Temperature Sensor
| Category | Heat Tracing Cables & Systems |
|---|
| Eltherm ELSR-SHH Heater Cable | Nominal Output | Cable Dimensions Approx. (mm) | Cable Weight Approx. (g/m) |
| ELSR-SHH-15-2-BOT | 15 W/m at 10ºC | 12.1 x 5.4 | 146 |
| ELSR-SHH-30-2-BOT | 30 W/m at 10ºC | 12.1 x 5.4 | 146 |
| ELSR-SHH-45-2-BOT | 45 W/m at 10ºC | 12.1 x 5.4 | 146 |
| ELSR-SHH-60-2-BOT | 60 W/m at 10ºC | 12.1 x 5.4 | 146 |
| ELSR-SHH-75-2-BOT | 75 W/m at 10ºC | 12.1 x 5.4 | 146 |
| Switch on temperature [°C] | Nominal fuse rating [A] | Heating circuit length*1 [m] | ||||
| ELSR-SHH15-2-BOT | ELSR-SHH30-2-BOT | ELSR-SHH45-2-BOT | ELSR-SHH60-2-BOT | ELSR-SHH75-2-BOT | ||
| 10 | 10 | 76.0 | 52.0 | 38.0 | 24.0 | 14.0 |
| 16 | 122.0 | 82.0 | 62.0 | 38.0 | 24.0 | |
| 20 | 154.0 | 102.0 | 76.0 | 46.0 | 28.0 | |
| 32 | 154.0 | 108.0 | 88.0 | 76.0 | 46.0 | |
| 0 | 10 | 70.0 | 46.0 | 32.0 | 18.0 | 12.0 |
| 16 | 112.0 | 74.0 | 52.0 | 30.0 | 18.0 | |
| 20 | 140.0 | 92.0 | 66.0 | 36.0 | 22.0 | |
| 32 | 146.0 | 104.0 | 84.0 | 58.0 | 36.0 | |
| -20 | 10 | 62.0 | 40.0 | 24.0 | 12.0 | 8.0 |
| 16 | 98.0 | 66.0 | 38.0 | 20.0 | 12.0 | |
| 20 | 122.0 | 82.0 | 46.0 | 26.0 | 16.0 | |
| 32 | 138.0 | 98.0 | 76.0 | 42.0 | 24.0 | |
| -40 | 10 | 52.0 | 30.0 | 14.0 | 8.0 | 4.0 |
| 16 | 82.0 | 50.0 | 24.0 | 12.0 | 8.0 | |
| 20 | 102.0 | 62.0 | 28.0 | 16.0 | 10.0 | |
| 32 | 126.0 | 88.0 | 46.0 | 24.0 | 14.0 | |
Tell us your quantity and requirements — we reply within one business day.
ATEX Heat Tracing | Hazardous Area Zones 1 & 2 (21 & 22)Eltherm ELSR-N-40-2-BO Self-Regulating Heating Cable
ATEX Heat Tracing | Hazardous Area Zones 1 & 2 (21 & 22)ELSR-N-40-2-AO Self-Regulating Heating Cable
ATEX Heat Tracing | Hazardous Area Zones 1 & 2 (21 & 22)ELSR-N-30-2-AO Self-Regulating Heating Cable
Share your specifications and quantities. Our team will review your request and come back with sourcing options and a quotation.