Water Heaters | ATEX Zone 1 & Zone 2 Hazardous Area HeatersEXHEAT RFA-OS Hazardous Area Oversink Water Heater – ATEX Certified Zone 1 & Zone 2
ATEX Water Heater | Zone 1 & Zone 2 (IIA, IIB, IIC) Hazardous Areas

ATEX Water Heater | Zone 1 & Zone 2 (IIA, IIB, IIC) Hazardous Areas
ATEX Water Heater | Zone 1 & Zone 2 (IIA, IIB, IIC) Hazardous Areas
EXHEAT FP-RCH hazardous area storage water heaters provide certified heating for Zone 1 & Zone 2 (Flammable Gas) hazardous areas and explosive atmospheres according to ATEX Directive. The FP-RCH range of water heaters provide bulk storage water heating and is ideal for vented water storage requirements.
The FP-RCH water heaters are suitable for single or multi-outlet use in applications such as laboratories, chemical plants, offshore installations, wash rooms in petrochemical installations and rest rooms on oil jetties that are designated as Zone 1 and Zone 2 hazardous areas, where the flammable atmosphere is a Group IIA, IIB or IIC gas.
The EXHEAT FP-RCH heaters are available in a range of different capacities from 25 to 100 litre all fitted with a control thermostat adjustable to 65ºC and can be wall mounted with either a right or a left hand water inlet connection.
Features of EXHEAT FP-RCH Water Heaters
Applications for water heaters include:
Certification: ATEX II 2 G
Ex d IIC T4 Gb Zone 1 and 2
CU TR (formerly GOST); CSA; Inmetro; KGS; CNEx; CCOE
When installing, the EXHEAT FP-RCH hazardous area storage water heater can be easily wall mounted and should be positioned a minimum of 1 metre above the highest draw off point.
Since 1985 as Leaders in ATEX Innovation we can facilitate succession planning for the replacement of obsolete, non-conformant and legacy equipment – we are the provider of innovative solutions to ensure ATEX and IECEx Compliance for Electrical, HVAC & Process Instrumentation systems in the explosive atmosphere industries.
| Category | ATEX Electric & Process Heaters |
|---|
| Casing | Hot water storage and cold water feed tanks are both manufactured from copper sheet with brazed seams |
| Casing | Corrosion proofed steel with white enamel finish |
| Insulation | CFC free, foiled, urethane slab |
| Heating Element | High quality 80/20 Nickel Chrome resistance wire compacted in Magnesium element insulating powder and encased in Incoloy 825 metal sheath |
| Enclosure | Cast Aluminium alloy with one M25 cable entry, external and internal earths and screwed terminal cover |
| Controls | Box cut out for T class hazardous area protection and float switch for element protection |
| Mounting | Wall mounting – minimum 1 metre above the highest draw off point |
| Rating | 2KW, 240V water heater |
| Hazardous Area Certification | ATEX certified Ex II 2 G Ex’d’ IIC T4 to T6 EN60079-0 and EN60079-1 |
| Part Number | Hazardous Area | Capacity (Litres) | Water Heater Dimensions | Weight (Kg) | ||
| Hot Water | Cold Water | Empty | Full | |||
| EXHEAT FP-RCH25 | Zone 1 & Zone 2 | 25 Litres | 8 Litres | Overall Height – 780mm,Overall Length – 470mm, Overall Width – 210mm | 24 | 57 |
| EXHEAT FP-RCH50 | Zone 1 & Zone 2 | 50 Litres | 24 Litres | Overall Height – 780mm,Overall Length – 470mm, Overall Width – 210mm | 36 | 110 |
| EXHEAT FP-RCH75 | Zone 1 & Zone 2 | 75 Litres | 24 Litres | Overall Height – 780mm,Overall Length – 470mm, Overall Width – 210mm | 41 | 140 |
| EXHEAT FP-RCH100 | Zone 1 & Zone 2 | 100 Litres | 24 Litres | Overall Height – 780mm,Overall Length – 470mm, Overall Width – 210mm | 44 | 168 |
Tell us your quantity and requirements — we reply within one business day.
Water Heaters | ATEX Zone 1 & Zone 2 Hazardous Area HeatersATEX Water Heater | Zone 1 & Zone 2 (IIA, IIB, IIC) Hazardous Areas
Water Heaters | ATEX Zone 1 & Zone 2 Hazardous Area HeatersATEX Water Heater | Zone 1 & Zone 2 (IIA, IIB, IIC) Hazardous Areas
Share your specifications and quantities. Our team will review your request and come back with sourcing options and a quotation.