Rotronic CP11 CO2 Gas Measurement Instrument Meter

Rotronic CP11 CO2 is a carbon dioxide measurement instrument – the economical multiple parameter meter for measuring and recording levels of CO2 gas also calculates dew point and wet bulb temperature.

BrandRotronic
CategoryProcess Instrumentation
  • Quoted to your quantity
  • Documentation on request
  • International delivery

Product Overview

Rotronic CP11 CO2 is a carbon dioxide measurement instrument – the economical multiple parameter meter for measuring and recording levels of CO2 gas also calculates dew point and wet bulb temperature.

The Rotronic CP11 instrument is equipped with the field-tested Rotronic Hygromer IN-1 humidity sensor offering unbeatable value for money.

Typical applications of the Rotronic CP11 include air quality monitoring in underground car parks for safety and leak monitoring in filling plants.

Product Benefits

Key Features – The Rotronic CP11 is capable of calculating dew point and wet bulb temperature and features automatic or manual logging. There is also easy field calibration by simple connection to a known reference.

Connections – The CP11 features a mini USB port for connection to a PC and a 5 VDC power supply, for connection of the optionally available AC adapter.

Large Display And Controls – With a back-light for improved reading. There are also large buttons for easy operation of the measuring instrument.

Sensors/Calibration – The Rotronic CP11 features the Hygromer IN-1 humidity sensor. Calibration is possible at 35/80 %RH and calibration of CO2 possible at 0 and 400 ppm.

Principles Of Operation

Rotronic CP11 handheld instrument evaluates the quality of air along with a measurement of the levels of carbon dioxide (CO2) gas present. In closed areas with inferior ventilation and populated with people, carbon dioxide levels can quickly develop in high concentrations.

CO2 gas is colourless and odourless making it impossible for humans to detect alone. In addition the gas occurs naturally in the earth’s atmosphere and a high CO2 content becomes apparent in humans through rapid fatigue and loss of concentration.

In order to initiate suitable counter measures such as an increase in the supply of fresh air, it is important to data log and record not only parameters such as relative humidity and temperature measurement, but also the CO2 gas content.

Rotronic – Carbon Dioxide GAS Measurement for Ventilation Monitoring

Rotronic devices including transmitters, data loggers and hand held instruments are used for regulating ventilation in living areas, offices, classrooms, cinemas, hospitals and also for measuring CO2 pollution in garages, tunnels and logistics facilities. Rotronic carbon dioxide gas measurement instruments monitor indoor air quality (IAQ) safeguarding the health, productivity and comfort of occupants.

Rotronic Measurement

View the current Rotronic catalogue :

Technical Specifications

BrandRotronic
CategoryProcess Instrumentation
TypeParametersRange of applicationPower supplyIP ProtectionClockAlarm
Handheld deviceCO2 gas, relative humidity and temperature0…50 °C / 0…100 %RH, non-condensing4 x AA batteries / optional AC adapter AC1214IP30Real time clockAdjustable for CO2 measurement
Battery lifeCurrent consumptionWarm-up timeCalculationsMeasured value memory
50 h40 mA (typical)<1 min.Dew point, wet bulb temperature18,000 values with time stamp, automatic recording (%RH / °C / ppm) 99 single values with time stamp, manual recording (%RH / °C / DP / Tw / ppm)
Measurement principleMeasurement rangeAccuracy at 23 °C ±5 KResponse timeAdjustment pointsPressure dependenceNull driftMaintenance
Non dispersive infrared (NDIR) with automatic baseline correction (ABC)0…5000 ppm±30 ppm ±5 % of the measured value<10 sec @ 30 cc/min. flow, <3 min diffusion time0, 400 ppm+1.6 % reading per kPa<10 ppm/yearNo maintenance
350 – 450 ppm400 – 1,200 ppm>1,000 ppm5,000 ppm (0.5 %vol)38,000 ppm (3.8 %vol)>100,000 ppm (10%vol)
Fresh air outdoorsRoom airFatigue and loss of concentration become apparent.Maximum permissible value at the workplace during an 8-hour workdayBreathing air (direct exhalation)Nausea, vomiting, loss of consciousness and death