ATEX Portable & Temporary Lighting – Hazardous Area Zone 1 & Zone 2 LightingWolf XT-606 ATEX Flood Bank
Gas: Hazardous Area Zone 0, Zone 1 & Zone 2

Wolf WF-300XL
Wolf WF-300XL
Floodlights for Zone 1,2 Zone 21, 22 Hazardous Area Lighting
WF-300XL floodlites are high powered, robust, lightweight and portable, producing 6,378 lumens with a low power consumption of only 55W (LV) or 62W (HV).
Two LED panels with 18 lights provide a 33º beam angle with more than 100,000 hours of life assured by efficient heat dissipation through built-in fins and electronic thermal control.
Wolf WF-300XL LinkEx LED Floodlites are supplied with 10 metres of SY cable and fitted with an ATEX plug and runs with voltages of 90 to 264V AC/DC or 18 to 50V AC/DC.
For mains voltages it can also be fitted with an ATEX socket to setup a string of lights from a single power source.
The LinkEx LED Floodlite is constructed with a robust marine grade aluminium enclosure with corrosion resisting coating is ideal for harsh environments.
The lens is a toughened, scratch, impact and chemical resistant glass, which can be protected using a disposable anti-static lens film and is sealed dust tight and protected from water immersion with a certified IP66/67 enclosure.
Supplied with a stainless steel (316 grade) bridle for pivot angle adjustment and bolted to a stainless steel stand for protection. The floodlite is fitted to a stainless steel bridle and stand which can be pivoted and can easily be detached and bolted to magnet fixings or a tripod stand.
Wolf WF-300XL floodlight provides reliable and versatile hazardous area lighting according to both ATEX Directive and IECEx standards – the floodlight utilise LED technology as a light source and are used for safe lighting in hazardous area Zones 1 and Zones 2 (potentially explosive gas) and Zones 21 and Zones 22 dust atmospheres (IIIA, IIIB & IIIC Groups) with T4 temperature classification.
An overview of the Wolf ATEX WF-300XL floodlight range to provide temporary lighting in explosive atmospheres:
The Wolf WF-300XL range are floodlight manufactured by Wolf Safety Lamp to provide lighting in Zone 1, Zone 2, Zone 21 or Zone 22 hazardous areas – the LED floodlight are for use in potentially explosive atmospheres according to the ATEX Directive.
Medium Flood (33.5°) (as per Light Output Diagram)
Light intensity at 2m 3573 lux, 5m 572 lux
LV output at LED source – 8,447 Lumens
LV output emitted from Floodlite – 6,129
HV output at LED source – 8,668
HV output emitted from Floodlite – 6,378
| Category | ATEX Portable & Temporary Lighting |
|---|
| Wolf Part Reference | Wolf WF-300XL | ||
| Floodlite Description | LinkEx LED Floodlite | ||
| Voltage | 18-50V AC/DC (LV) | 90-264V AC/DV (HV) | |
| Hazardous Area Code (ATEX & IECEx) | II 2 G D Ex eb mb op is IIC T4 Gb Ex tb op is IIIC T118°C Db T = -40°C to +55°C | ||
| Equipment Category | 2GD | ||
| Type of Protection | ‘eb’ Increased Safety, ‘mb’ encapsulation, ‘tb’ enclosure protection | ||
| Area of Hazardous Classification (Gas) | Zones 1 & 2, Gas Group IIA, IIB, IIC | ||
| Temperature Classification (Gas) | T4 | ||
| Area of Hazardous Classification (Dust) | Zones 21 and 22, Dust Groups IIIA, IIIB and IIIC | ||
| Maximum Surface Temperature (Dust) | T118ºC | ||
| Ambient Temperature | -40ºC to +55ºC | ||
| ATEX Certificate | SIRA17ATEX3035X IECExSIR17.0013X | ||
| Enclosure | Marine Grade Aluminium Alloy, Epoxy Powder Coated | ||
| Lens | Toughened Glass | ||
| Beam Type | Medium Flood | ||
| Light Source | Type | 36 x White High Power LED | |
| Power | 55W | 62W | |
| Output At LED Source | 8,447 lumens | 8,668 lumens | |
| Output Emitted From Floodlite | 6,129 lumens | 6,378 lumens | |
| Life | 100,000+ Hours (Fitted for Life) | ||
| Ingress Protection | IP66/67 | ||
| Weight | 7.3kg (excluding cable) | ||
| Accessories | Supplied with bridle and lamp stand | ||
Tell us your quantity and requirements — we reply within one business day.
ATEX Portable & Temporary Lighting – Hazardous Area Zone 1 & Zone 2 LightingGas: Hazardous Area Zone 0, Zone 1 & Zone 2
ATEX Portable & Temporary Lighting – Hazardous Area Zone 1 & Zone 2 LightingGas: Hazardous Area Zone 0, Zone 1 & Zone 2
ATEX Portable & Temporary Lighting – Hazardous Area Zone 1 & Zone 2 LightingGas: Hazardous Area Zone 0, Zone 1 & Zone 2
Share your specifications and quantities. Our team will review your request and come back with sourcing options and a quotation.