5 Day Express Service for Hazardous Area ProductsIncreased Safety Control Stations | Hazardous Area Zone 1 Zone 2 | Appleton ATX U63W2A5A9D3
Zone 1 & Zone 2 (Gas) | Zone 21 & Zone 22 (Dust) Hazardous Areas

Product Category: Control Stations | ATEX Certified | Zone 1 & Zone 2 Hazardous Areas
Product Category: Control Stations | ATEX Certified | Zone 1 & Zone 2 Hazardous Areas
Increased Safety Unicode 2 Series polyamide control stations and switches, manufactured by Appleton ATX, are ideal for use in hazardous areas and washdown areas. A variety of push buttons, selector switches, illuminated push buttons, control and load break switches and LED pilot lights are available for use in conjunction with contactors or magnetic starters for the remote control of motors. The ATEX certified control stations provide safe circuit control and/or selection in potentially explosive atmospheres. Pilot lights are available to provide visual assurance that an electrical function is being performed at a remote or local location. These polyamide control stations are ideal for the control of equipment at power, chemical and petrochemical plants, petroleum refineries, re-verse osmosis plants, pulp and paper processing plants and various other industrial applications.
Appleton Unicode 2 Series uses the Ex de method of protection which eliminates the need for external seals. Unicode 2 Series features a choice of DIN rail mounted high performance contact block suitable for low intensity (less than 5 mA). TS35 rail mounted components are held securely in place during operation and easily removed for service.
Contact block technical data: IEC rated operating voltage (Ue): 500 Vac – 110 Vdc. IEC switching capacity: AC12: 16 Amp/400 Vac, AC14: 10 Amp/400 Vac, AC15: 6 Amp/500 Vac, DC13: 2 Amp/24 Vdc and 1 Amp/110 Vdc. NEMA switching capacity: A600: 10 Amp/600 Va.
Selector switch technical data: IEC rated operating voltage: 690 Vac. IEC rated operating current: maximum 16 Amp. IEC switching capacity: AC1: 16 Amp/690 Vac, AC15: 16 Amp/415 Vac, AC3: 8 Amp/500 Vac, AC3: 4 Amp/690 Vac, AC3: 16 Amp/690 Vac, DC1: 10 Amp.
The following information relates to the hazardous area certification and approvals for this range of control stations for specification purposes – should you require any further information please contact our team.
— Gas: Zone 1 and Zone 2
– Conforming & Approved to ATEX 94/9/CE: II 2 G
– Type of Explosion Protection: Ex de IIC/Ex demb IIC (depending of the actuator)
– Temperature Class: T6 T Rating for Hazardous Area Locations
— Dust: Zone 21 and Zone 22
– Conforming & Approved to ATEX 94/9/CE: II2 D
– Type of Explosion Protection: Ex tD A21
— Surface Temperature: T75 °C (T167 °F)
— Ambient Temperature: -20 °C to +55 °C (-4 °F to +131 °F)
— CE Declaration of Conformity: 50221
— ATEX Certificate: LCIE 00 ATEX 6047
| Category | ATEX Control Stations |
|---|
| Control Station | Appleton ATX Order Code |
| Push Button “I” or “O” (NO+NC) – 2 x M20 | U41W2A3 |
| Push Button “I” (NO) – 2 x M20 | U41W2A5 |
| Push Button “O” (NO+NC) – 2 x M20 | U41W2A9 |
| Emergency Stop (NC) – 2 x M20 | U41W2D9 |
| Emergency Stop (NO+NC) – 2 x M20 | U41W2D3 |
| Emergency Stop with Key Release (NC) – 2 x M20 | U41W2C9 |
| Emergency Stop with Key Release (NO+NC) – 2 x M20 | U41W2C3 |
| Black Mushroom Head (NC) – 2 x M20 | U41W2B3 |
| Red Mushroom Head (NO+NC) – 2 x M20 | U41W2R9 |
| Key Push Button (NO+NC) 2 x M20 | U41W2E3 |
| 2-Position Selector Switch (NO+NC) – 2 x M20 | U41W2H3 |
| 3-Position Selector Switch 3 fixed position “I-0-II” (2NO) – 2 x M20 | U41W2J1 |
| Pilot Light – Red | U41W2PR |
| Pilot Light – Green | U41W2PG |
| Pilot Light – Blue | U41W2PB |
| Pilot Light – Yellow | U41W2PY |
| Pilot Light – White | U41W2PW |
| Push Button “I” (NO) and Push Button “O” (NC) – 2 x M20 | U42W2A5A9 |
| Push Button “I” (NO+NC) and Push Button “O” (NO+NC) – 2 x M20 | U42W2A3A3 |
| Push Button “I” (NO) and Red Mushroom Head (NC) – 2 x M20 | U42W2A5D9 |
| Push Button “I” (NO+NC) and Red Mushroom Head (NO+NC) – 2 x M20 | U42W2A3D3 |
| Pilot Light – Green and Push Button “I” (NO) – 2 x M20 | U42W2PGA5 |
| Pilot Light – Green and Push Button “I” (NO+NC) – 2 x M20 | U42W2PGA3 |
| Pilot Light – Red and Push Button “O” (NO) – 2 x M20 | U42W2PRA9 |
| Pilot Light – Red and Push Button “O” (NO+NC) – 2 x M20 | U42W2PRA3 |
| Ammeter 48 x 48mm, 1A current transformer, Scale 0-1-3 | U42W2VA13 |
| Push Button “I” (NO), Push Button “O” (NC) and Red Mushroom Head (NO+NC) – 2 x M20 | U43W2A5A9D3 |
| Push Button “I” (NO+NC), Push Button “O” (NO+NC) and Red Mushroom Head (NO+NC) – 2 x M20 | U43W2A3A3D3 |
| Pilot Light – Green, Push Button “I” (NO) and Push Button “O” (NC) – 2 x M20 | U43W2PGA5A9 |
| Pilot Light – Green, Push Button “I” (NO+NC) and Push Button “O” (NO+NC) – 2 x M20 | U43W2PGA3A3 |
| Pilot Light – Green, Push Button “I” (NO) and Push Button “O” (NC) – 2 x M20 | U43W2PRA5A9 |
| Pilot Light – Green, Push Button “I” (NO+NC) and Push Button “O” (NO+NC) – 2 x M20 | U43W2PRA3A3 |
| Ammeter 48 x 48mm, 1A current transformer, Scale 0-1-3, Push Button “I” (NO) and Push Button “O” (NC) – 2 x M20 | U43W2VA13A5A9 |
| Ammeter 48 x 48mm, 1A current transformer, Scale 0-1-3 and 3-position Selector Switch with spring return “I-0II” (NO+NC) – M20 | U43W2VA13M3 |
Tell us your quantity and requirements — we reply within one business day.
5 Day Express Service for Hazardous Area ProductsZone 1 & Zone 2 (Gas) | Zone 21 & Zone 22 (Dust) Hazardous Areas
5 Day Express Service for Hazardous Area ProductsZone 1 & Zone 2 (Gas) | Zone 21 & Zone 22 (Dust) Hazardous Areas
5 Day Express Service for Hazardous Area ProductsZone 1 & Zone 2 (Gas) | Zone 21 & Zone 22 (Dust) Hazardous Areas
Share your specifications and quantities. Our team will review your request and come back with sourcing options and a quotation.