SICK S700 | Extractive Gas Analyser For Hazardous Area Emission Monitoring

Tailor-made gas analysis for process and emission monitoring

BrandSICK
CategoryGas Detection
  • Quoted to your quantity
  • Documentation on request
  • International delivery

Product Overview

Sick S700

Tailor-made gas analysis for process and emission monitoring

The S700 modular system is an extractive gas analyser manufactured by SICK which is very easy to configure and provides a tailor-made application.

The housing of the S700 can be equipped with up to 3 analyser modules for a compact and cost-effective system solution – A total of 6 different analyser modules are available for analysing more than 60 gas components.

Depending on the measuring task, installation site, and ambient conditions, the following housing types are available:

  • S710 19″ rack: Suitable for analyser cabinets and standard applications
  • S715 wall-mounting enclosure: For applications in harsh conditions and ATEX certified Zone 2 potentially explosive environments
  • S720 flame-proof housing: For Zone 1 explosive environment (ATEX)

Typical Applications for SICK S700

  • Emission measurement according to 13th (2001/80/EC), 17th (2000/76/EC), and 27th German Federal Emission Protection Directive (BImSchV).
  • Cooling gas monitoring of turbo generators
  • Measurement of CO for coal mill monitoring
  • Purity measurement of H2 in pressure swing adsorption plants
  • Monitoring of CO2 in natural gas in natural gas conditioning plants

Features

  • 5 different measurement principles available
  • More than 60 measuring components to choose from
  • 3 different housing variants for different fields of application
  • Up to 3 analyser modules in a single housing
  • Easy application-specific adaptation due to modular design
  • Also suitable for zone 1 and zone 2 explosive environments (ATEX)
  • Automatic adjustment with test gas or calibration cell
  • Integrated self-monitoring and fault diagnosis

Product Variations

Different housing variants are available depending on the location of use and ambient conditions:

A housing can accept up to 3 analyser modules. The table below shows the selection of analyser modules available. These modules are differentiated using the following measurement principles:

  • NDIR spectroscopy (UNOR & MULTOR)
  • Electrochemical cell (OXOR-E)
  • Paramagnetic dumbbell principle (OXOR-P)
  • Interference filter correlation (FINOR)
  • Thermal conductivity measurement (THERMOR)

Simply combine modules from each the different groups to suit your application.

SICK s700 – Housing Types

Please note: The exact device specifications and performance data of the product may deviate from the information provided here, and depend on the application in which the product is being used and the relevant customer specifications.

FOR EXPLOSIVE ATMOSPHERES & Hazardous Areas

Key Product Categories: Control Panels | Plugs & Sockets | Isolators | Enclosures & Junction Boxes | Lighting | Control Stations | Motor Starters | Heat Trace Cables & Systems | Gas Detection & Detectors | Fire Detection & Detectors | Heat Detectors | Electrical Heating & Heaters

Also Process Instrumentation Products: Ashcroft Pressure Gauges | ASCO Valves | Katronic Flow Meters | KROHNE Flow Meters | VEGA Level Sensors | Rotronic Temperature & Humidity Sensors | SIKA Pressure Gauges

Technical Specifications

BrandSICK
CategoryGas Detection
Analyser Modules
Group 1Group 2Group 3
UNORUNOR¹THERMOR
MULTOROXOR-EOXOR-E
OXOR-EOXOR-POXOR-P
OXOR-PNo ModuleNo Module
FINOR¹ Not compatible if FINOR selected in Group 1
No Module
Measured ValuesAr, CBrF3, CClF3, CCl2F2, CCl3F, CHClF2, CHCl3, CH2Cl2, CH2O, CH3Cl, CH3OH, (CH3)2O, CH4, CO, CO2, CS2, C2Cl2F4, C2Cl3F3, C2Cl4, C2HCl3, C2H2, C2H2Cl2, C2H2F4, C2H3Cl3, C2H4, C2H4Cl2, C2H5OH, C2H6, C3H4, C3H6, C3H7OH, C3H8, C3H8O2, C4H6, C4H8, C4H10, C4H8O, C4H9OH, C5H12, C6H10O, C6H12, C6H14, C7H16, C7H8, C8H10, He, H2, H2O, NH3, NO, N2O, O2, SF6, SO2
Performance-Tested MeasurandsCO, NO, O2, SO2
Gas Flow RateNo integrated sample gas pump: 5 l/h … 100 l/h With integrated sample gas pump: 30 l/h … 60 l/h
Sample Gas Temperature0 °C … +45 °C Temperature at analyser inlet
Process PressureTubed gas lines –200 hPa … 1,000 hPa Hosed gas lines: –200 hPa … 300 hPa
Process Gas HumidityNon-condensing
Dust LoadFree of dust and aerosols
Ambient Temperature+5 °C … +45 °C
Storage Temperature–20 °C … +70 °C
Ambient Pressure700 hPa … 1,200 hPa
Geographical Altitude≤ 2,000 m (above mean sea level)
Ambient Humidity≤ 95 % Relative humidity; non-condensing
Electrical SafetyCE, cCSAus
Enclosure RatingIP20
Analog Outputs4 outputs: 4 … 20 mA, + 500 Ω 0 … 10 V Electrically isolated
Analog Inputs2 inputs: 0/2/4 … 20 mA Option: 0 … 10 V DC
Digital Outputs8 relay contacts: Three relay outputs pre-set for failure, service and maintenance
Digital Inputs8 optical coupler inputs: Electrically isolated; freely programmable
Communication InterfaceModbus Type of fieldbus integration: RTU RS-232
Number1
IndicationLC Display
OperationMenu-driven operation via LC-display and membrane keyboard
Menu LanguagesGerman, English, French, Italian, Dutch, Polish, Swedish, Spanish
Model19″ rack enclosure with 3 rack units, for integration in cabinets
Dimensions (W x H x D)483 mm x 132.5 mm x 332 mm
Weight9 kg … 12 kg Depending on configuration
Power SupplyVoltage: 100 V / 115 V / 230 V Frequency: 48 … 62 Hz Power consumption: ≤ 150 W Depending on system configuration
Corrective FunctionsAutomatic testing and adjustment with test gases Manual adjustment with test gases
OptionsIntegrated sample gas pump (only with hosed gas lines) Tubed gas lines Up to 3 separate gas lines Flow sensor Humidity sensor Barometric pressure correction Sample gas pressure correction Sample point switching (max. 8 sample points)
Description19″ rack enclosure with 3 rack units, for integration in cabinets
Electrical SafetyCE
Enclosure RatingIP20
Dimensions (W x H x D)483 mm x 132.5 mm x 390 mm
Weight10 kg … 20 kg Depending on configuration
Sample Gas ConnectionsPVDF bulkhead fitting: for hose 6 x 1 mm Optional: Swagelok 6 mm / Swagelok ¼”
Description19″ rack enclosure with 3 rack units and reduced depth, for integration in cabinets
Electrical SafetyCE
Enclosure RatingIP20
Dimensions (W x H x D)483 mm x 132.5 mm x 390 mm
Weight9 kg … 19 kg Depending on configuration
Sample Gas ConnectionsPVDF bulkhead fitting: for hose 6 x 1 mm Optional: Swagelok 6 mm / Swagelok ¼”
DescriptionWall-mounting enclosure with gas-tight separated analysing and electronic units, purgeable separately
Hazardous Area ApprovalsATEX: II 3G Ex nR II T6
Electrical SafetyCE
Enclosure RatingIP65 / NEMA 4x
Dimensions (W x H x D)555 mm x 470 mm x 288 mm
Weight20 kg … 30 kg Depending on configuration
Sample Gas ConnectionsInside thread G1/4″: for screw-in fittings Option 1: PVDF bulkhead fitting: for hose 6 x 1 mm Option 2: Swagelok 6 mm Option 3: Swagelok ¼”
Auxiliary Gas ConnectionsPurge gas: Inside thread G1/4″: for screw-in fittings Option 1: Swagelok 8 mm Option 2: Swagelok 10 mm Option 3:Swagelok 3/8″
OptionsIntrinsically safe outputs for measured values
DescriptionFlame-proof (Ex d) enclosure for use in ATEX Zone 1 certified areas
Hazardous Area ApprovalsATEX II 2G Ex db ia [ia] IIC T6 Gb II 2G Ex db ia IIC T6 Gb
Electrical SafetyCE
Enclosure RatingIP65 / NEMA 7
Dimensions (W x H x D)480 mm x 480 mm x 276 mm
Weight60 kg … 70 kg Depending on configuration
Sample Gas ConnectionsInside thread G1/4″: for screw-in fittings Option 1: PVDF bulkhead fitting: for hose 6 x 1 mm Option 2: Swagelok 6 mm Option 3: Swagelok ¼”
Auxiliary Gas ConnectionsPurge gas: Inside thread G1/4″: for screw-in fittings
OptionsIntrinsically safe outputs for measured values
DescriptionFlame-proof (Ex d) enclosure for use in ATEX Zone 1 certified areas with large analyser unit for maximum system configuration
Hazardous Area ApprovalsATEX II 2G Ex db ia [ia] IIC T6 Gb II 2G Ex db ia IIC T6 Gb
Electrical SafetyCE
Enclosure RatingIP65 / NEMA 7
Dimensions (W x H x D)596 mm x 480 mm x 300 mm
Weight90 kg … 100 kg Depending on configuration
Sample Gas ConnectionsInside thread G1/4″: for screw-in fittings Option 1: PVDF bulkhead fitting: for hose 6 x 1 mm Option 2: Swagelok 6 mm Option 3: Swagelok ¼”
Auxiliary Gas ConnectionsPurge gas: Inside thread G1/4″: for screw-in fittings
OptionsIntrinsically safe outputs for measured values
Phase-Out
DescriptionRugged IR analyser with no moving parts for measuring gases in vol. % range
Measurement PrinciplesInterference filter correlation
Measuring RangesCH4: 0 … + 2 Vol.-% CO: 0 … + 0.5 Vol.-% CO2: 0 … + 0.1 Vol.-% SF6 : 0 … + 10 Vol.-%
Response Time (t90)≤ 25s Typical at 60 l/h, depending on cuvette length, gas flow & number of measuring components
Sensitivity drift≤ 1 %: per week
Zero point drift≤ 1.5 %: of smallest measuring range per week
Material in contact with mediaViton B, PVDF, stainless steel 1.4571, Aluminium, Calciumfluorid
DescriptionMulti-component NDIR analyser for continuous measurement of up to 3 IR-absorbing gases and H2O for internal interference sensitivity correction
Measurement PrinciplesNDIR spectroscopy
Measuring RangesCH4: 0 … 470 ppm / 0 … 100 Vol.-% CO: 0 … 160 ppm / 0 … 100 Vol.-% CO2: 0 … 100 ppm / 0 … 100 Vol.-% NO: 0 … 190 ppm / 0 … 100 Vol.-% SO2: 0 … 85 ppm / 0 … 100 Vol.-%
Certified Measuring RangesCO: 0 … 200 mg/m³ NO: 0 … 250 mg/m³ SO2: 0 … 250 mg/m³ Certified according to EN 14181:2004
Response Time (t90)≤ 25s Typical at 60 l/h, depending on cuvette length, gas flow & number of measuring components
Sensitivity drift≤ 1 %: of measuring range full scale per week
Zero point drift≤ 1 %: of smallest measuring range per week
Conformities2001/80/EC (13. BImSchV) TA-Luft (Prevention of Air Pollution) EN 14181:2004
Material in contact with mediaViton B, PVDF, Calciumfluorid, Bariumfluorid, stainless steel 1.4571, gold, Aluminium
Corrective FunctionsManual or automatic adjustment with test gases or adjustment cell
DescriptionHeat conductivity analyser for the determination of concentrations in binary or quasi-binary gas mixtures
Measurement PrinciplesThermal conductivity measurement
Measuring RangesH2 in Ar: 0 … 1 Vol.-% / 0 … 100 Vol.-% H2 in CH4: 0 … 1 Vol.-% / 0 … 100 Vol.-% H2 in CO2: 0 … 1 Vol.-% / 0 … 100 Vol.-% H2 in blast furnace gas: 0 … 1 Vol.-% / 0 … 100 Vol.-% H2 in N2: 0 … 1 Vol.-% / 0 … 100 Vol.-% H2 in O2: 0 … 1 Vol.-% / 0 … 100 Vol.-% Other measuring ranges & components on request
Response Time (t90)≤ 20s At a gas flow of 60 l/h
Sensitivity drift≤ 1 %: of measuring range full scale per week
Zero point drift≤ 1 %: of smallest measuring range per week
Material in contact with mediaGlass, stainless steel 1.4571, PVDF (HCl resistant version)
Corrective FunctionsManual or automatic adjustment with test gases
DescriptionHighly selective NDIR analyser for continuous measurement of almost any gas component which absorbs in the infra-red spectral range
Measurement PrinciplesNDIR spectroscopy
Measuring Ranges (More than 60 measuring components available)CH4: 0 … 100 ppm / 0 … 100 Vol.-% C2H2: 0 … 300 ppm / 0 … 100 Vol.-% C2H4: 0 … 300 ppm / 0 … 100 Vol.-% Frigen 11, CCl3F: 0 … 500 ppm / 0 … 50 Vol.-% Frigen 134a, C2H2F4: 0 … 100 ppm / 0 … 100 Vol.-% Frigen 22, CHClF2: 0 … 100 ppm / 0 … 100 Vol.-% C2H6: 0 … 100 ppm / 0 … 100 Vol.-% C2H2Cl2: 0 … 500 ppm / 0 … 30 Vol.-% C3H6: 0 … 300 ppm / 0 … 100 Vol.-% C3H8: 0 … 100 ppm / 0 … 100 Vol.-% C4H10: 0 … 100 ppm / 0 … 100 Vol.-% C5H12: 0 … 300 ppm / 0 … 100 Vol.-% C6H14: 0 … 300 ppm / 0 … 10 Vol.-% CO: 0 … 20 ppm / 0 … 100 Vol.-% CO2: 0 … 10 ppm / 0 … 100 Vol.-% NH3: 0 … 300 ppm / 0 … 100 Vol.-% NO: 0 … 75 ppm / 0 … 100 Vol.-% N2O: 0 … 50 ppm / 0 … 100 Vol.-% SF6:0 … 50 ppm / 0 … 100 Vol.-% SO2: 0 … 85 ppm / 0 … 100 Vol.-%
Certified Measuring RangesCO: 0 … 100 mg/m³ NO: 0 … 100 mg/m³ SO2: 0 … 100 mg/m³ Certified according to EN 14181:2004
Response Time (t90)3s Typical at 60 l/h, depending on cell length & gas flow
Sensitivity drift≤ 1 %: of measuring range full scale per week
Zero point drift≤ 1 %: of smallest measuring range per week
Conformities2001/80/EC (13. BImSchV) 2000/76/EC (17. BImSchV) 27. BImSchV TA-Luft (Prevention of Air Pollution) EN 14181:2004
Material in contact with mediaViton B, PVDF, Calciumfluorid, Bariumfluorid, stainless steel 1.4571, gold, Aluminium
Corrective FunctionsManual or automatic adjustment with test gases or adjustment cell
DescriptionDetermination of oxygen content using an electrochemical cell
Measurement PrinciplesElectrochemical cell
Measuring RangesO2: 0 … 10 Vol.-% / 0 … 25 Vol.-%
Certified Measuring RangesO2: 0 … 25 Vol.-% Certified according to EN 14181:2004
Response Time (t90)≤ 20s Typical at 60 l/h, depending on gas flow
Sensitivity drift≤ 1 %: of measuring range full scale per week
Zero point drift≤ 2 %: of smallest measuring range per week
Process PressureAnalyser inlet: –200 hPa … 300 hPa Relative
Conformities2001/80/EC (13. BImSchV) 2000/76/EC (17. BImSchV) 27. BImSchV TA-Luft (Prevention of Air Pollution) EN 14181:2004
Material in contact with mediaViton B, PVDF, stainless steel 1.4571
Corrective FunctionsManual or automatic adjustment with test gases
DescriptionAccurate oxygen analyser which operates according to the paramagnetic measurement principle
Measurement PrinciplesParamagnetic dumbbell principle
Measuring RangesO2: 0 … 1 Vol.-% / 0 … 100 Vol.-%
Certified Measuring RangesO2: 0 … 25 Vol.-% Certified according to EN 14181:2004
Response Time (t90)≤4s Typical at a gas flow of 60 l/h
Sensitivity drift≤ 1 %: of measuring range full scale per week
Zero point drift≤ 1 %: of smallest measuring range per week Measuring ranges smaller 5 Vol%: ≤ 0.05 Vol.-%: per week
Conformities2001/80/EC (13. BImSchV) 2000/76/EC (17. BImSchV) 27. BImSchV TA-Luft (Prevention of Air Pollution) EN 14181:2004
Material in contact with mediaViton B, PVDF, glass, stainless steel 1.4571, platinum, nickel, Aluminium
Corrective FunctionsManual or automatic adjustment with test gases
RemarkSpecial versions with highly solvent-resistant or highly corrosion-resistant measuring cells available

Request Information About This Product

Tell us your quantity and requirements — we reply within one business day.

Related Products

Have a product requirement?

Share your specifications and quantities. Our team will review your request and come back with sourcing options and a quotation.