Self Regulating Trace Heating | Eltherm ELSR-M Trace Heating Cable (Up to 65 Degrees Celsius)

Trace Heating Cable | Eltherm ELSR-M

CategoryHeat Tracing Cables & Systems
  • Quoted to your quantity
  • Documentation on request
  • International delivery

Product Overview

Self Regulating Trace Heating

Trace Heating Cable | Eltherm ELSR-M

Eltherm ELSR-M is a versatile self-regulating trace heating cable that provides process temperature maintenance and frost protection to pipework, instrument lines, tanks and drums up to 65° Celsius.

The self-regulating trace heating technology allows the heating cable to increase or decrease its heat output based on the ambient temperature, providing energy-efficient operation and preventing overheating. ELSR-M is suitable for use in various industrial applications where maintaining consistent temperatures is critical for process integrity and safety including:

  • Heat tracing on pipes, pumps and valves
  • Food processing industry
  • Automotive
  • Heating of tube bundle cables for water analysis
  • Heat tracing on vessels

Our Team of Trained Sales Engineers are available to advise and support your trace heating enquiries – this includes design and supply of complex multi-kilometre, major-project systems to custom heat trace cable kits for the protection of winterisation against plant and factory facilities.

Eltherm ELSR-M Trace HEAting CABLE – SPECIFICATION

Eltherm ELSR-M self-regulating trace heating wattages per metre at 10°C – 10 and 15 watts.

  • Nominal Supply Voltage : 230v
  • Maximum Exposure Temperature : Power off 65°C, power on 65°C
  • Minimum Installation Temperature : -45° Celsius
  • Minimum Heater Cable Bend Radius : 25mm
  • Heater Cable Outer Jacket: TPE-O
  • Bus Wire: Nickel plated copper
  1. Bus wire – nickel plated copper, 0.62 mm²
  2. Self-regulating heating element
  3. Insulation
  4. Protective braid – (Cu, tin plated)
  5. Outer jacket – TPE-O
  6. Protective conductor connection – see 4 or Cu, tin plated with aluminium foil

Eltherm ELSR-M self-regulating heating cables are available in two cable designs. The BO version of the ELSR-M heating cable has a protective tin-plated copper braid for all low – temperature and medium – temperature applications.

  • BO: Protective braid and a thermoplastic outer jacket
  • AO: Aluminium foil and a thermoplastic outer jacket

Eltherm ELSR- M BENEFITS

  • Four nominal outputs
  • UV-resistant
  • Moisture proof
  • Highly durable
  • Efficient heat distribution
  • Junction box for pipe mounting

Eltherm ELSR- M heating cables provide temperature maintenance and frost protection to pipework and mechanical services in all industries – typical applications include heating process pipework, instrument lines and storage tanks to maintain viscosity or prevent frost damage as an integral work-task of plant Winterisation.

Eltherm ELSR-M cables utilise cold-applied installation components to complete the trace heating system – no requirement for “hot-working” permit applications in potentially explosive atmospheres, including Zone 1 and Zone 2 hazardous areas.

Trace Heating Cable Selection Table – Eltherm ELSR-M

Contact our team for technical guidance, heat loss calculations for pipework systems and optimum specification of the correct trace heating cable for your application.

ELSR-M Heating circuit length

*1 Heating circuit lengths on the following conditions:

  • 230 V nominal voltage
  • Delayed action circuit breakers (C-characteristic) with 80 % max. load
  • Maximum 10 % line voltage drop on heating cable bus wire
  • Power connection to one heater end
  • In certain installation situations, the heating circuit length may vary. Please contact our team

Eltherm video providing a step-by-step termination of ELSR-N heater cable using a EL-ECN termination kit.

Self-Regulating Trace Heating System

A Trace Heater
B Power Connection Kit
C End Termination Kit
D Junction Box
E Pipe Mounting Bracket
F Fasteners and Self-adhesive Tapes, Foils
G Insulation Bushing
H Warning Sign
I Temperature Controller
J Temperature Sensor

Technical Specifications

CategoryHeat Tracing Cables & Systems
Eltherm ELSR-M Heater CableNominal OutputCable Dimensions (mm)Cable Weight Approx (g/m)
ELSR-M-10-2-AO10 w/m at 10ºC8.0 x 5.553
ELSR-M-10-2-BO10 w/m at 10ºC8.5 x 5.862
ELSR-M-15-2-AO15 w/m at 10ºC8.0 x 5.553
ELSR-M-15-2-BO15 w/m at 10ºC8.5 x 5.862
Switch on temperature [°C]Nominal fuse rating [A]Heating circuit length*1 [m]
ELSR-M-10-2ELSR-M-15-2
1010126.098.0
16126.0105.0
20126.0105.0
010115.083.0
16115.097.0
20115.097.0
-101090.072.0
16144.091.0
20149.091.0
– 201078.064.0
16125.085.0
20139.085.0
-401062.052.0
1699.077.0
20124.077.0

Request Information About This Product

Tell us your quantity and requirements — we reply within one business day.

Related Products

Have a product requirement?

Share your specifications and quantities. Our team will review your request and come back with sourcing options and a quotation.