Chromalox SRL 5-2C 5W/FT 240V Trace Heating Cables

SRL trace heating cables manufactured by Chromalox, including SRL 5-2C, provide frost protection to pipework and valves, tanks and associated mechanical services – suitable for hazardous area zones including ATEX Zone 1…

CategoryHeat Tracing Cables & Systems
  • Quoted to your quantity
  • Documentation on request
  • International delivery

Product Overview

Trace Heating Cables

  • Manufacturer: Chromalox
  • Heating Cable Range: SRL
  • Heating Cable Code: SRL 5-2C 5W/FT 240V
  • Heating Cable Maximum Temperature Maintenance: 150°F (65°C)
  • Cable Type: Self Regulating Trace Heating Cables
  • Cable Ratings: 5 Watts Per Foot @ 50°F
  • Cable Voltage: 240V
  • Maximum Heating Cable Circuit Length: 540 Foot
  • See Also: Trace Heating

SRL trace heating cables manufactured by Chromalox, including SRL 5-2C, provide frost protection to pipework and valves, tanks and associated mechanical services – suitable for hazardous area zones including ATEX Zone 1 (Gas).

Hazardous Area Approvals

ATEX Directive

ATEX CE 0359 IIG Ex e IIC T* Gb Ta -60˚C to 195˚C

IECEx

ITS 07.0018X Ex e IIC T5 Gb Ta -60˚C to 95˚C

FM Factory Mutual Approved Heating Cables for ordinary areas

UL Listed CSA Certified for Ordinary Areas
UL Listed for Fire Protection System Piping

FM approved heating cables for hazardous (classified) areas when used with Chromalox cable accessories
• Class I, Div. 2, Groups B, C, D (gases, vapours)
• Class II, Div. 2, Groups F, G (combustible dust)
• Class III, Div. 2 (easily ignitable fibres and filings)
• 3 Watt rated T6 temperature class
• 5 and 8 Watt rated T5 temperature class
• 10 Watt rated T4A temperature class – more information T Class Ratings

CSA Certified for hazardous (classified) areas when used with Chromalox accessories
• Class I, Div. 2, Groups A, B, C, D;
• Class II, Div. 2, Groups F, G

  • See also : Electrical Heating for Hazardous Areas

Heating Cable Applications

  • Process Pipework Maintenance
  • Frost Protection of Pipework
  • Fluid Flow, Transfer & Viscosity Maintenance

Cable Ordering Information

  • Chromalox SRL 5-2C (PCN 382707) Heat Trace Cable Standard Tinned Copper Metallic Earth Braid for Ground Path
  • Chromalox SRL 5-2CR (PCN 382766) Heat Trace Cable TRP Overjacket for Protection Against Inorganic Chemical Solutions
  • Chromalox SRL 5-2CT (PCN 383451) Heat Trace Cable TPR Overjacket Fluoropolymer Corrosion Resistant Hazardous Areas

Technical Specifications

CategoryHeat Tracing Cables & Systems
Maximum Cable Circuit Length (Ft.) by Start-Up Temperature (°F) and Breaker Size (Amps)
Heating Cable RatingSRL 5-2C Trace Heating
50°F Start-Up (Ft.) Circuit Breaker10 A250
15 A375
20 A505
25 A540
30 ANR
40 ANR
0°F Start-Up (Ft.) Circuit Breaker10 A180
15 A270
20 A360
25 A450
30 A540
40 ANR
-20°F Start-Up (Ft.) Circuit Breaker10 A160
15 A245
20 A325
25 A405
30 A490
40 A540

Request Information About This Product

Tell us your quantity and requirements — we reply within one business day.

Related Products

Have a product requirement?

Share your specifications and quantities. Our team will review your request and come back with sourcing options and a quotation.