Product Overview
EX E MB Increased Safety & Encapsulated
ASCO EM/WSEM explosion proof solenoid valve operators are ATEX certified for installation in potentially explosive atmospheres located in hazardous areas.
The solenoid operators with Increased Safety and Encapsulation IEC explosion protection techniques. They are suitable for use in hazardous areas with exposure to gas, classified as Zone 1.
Hazardous Area Classification & Ex Safety Code
II 2G Ex e mb IIC T6..T3 Gb
II 2D Ex tb IIIC 85°C..200°C Db IP66/67
EC type certificate KEMA 98ATEX2542 X and IECEx certificate (IECEx KEM 08.0002X). IP66/67 ingress protection.
The Ex e mb solenoid operators used in conjunction with valves are compliant with International and European Standards EN-IEC 60079-0, EN-IEC 60079-7, EN-IEC 60079-18 and EN-IEC 60079-31 and also certified for use in potentially explosive atmospheres according to ATEX-Directive 2014/34/EU.
ASco EM/WSEM operators – features
- Ingress Protection Rating: IP66/67
- The solenoid operators have a zinc-plated steel (EM) or stainless steel (WSEM) enclosure which features integral strain relief for cable with an O.D. of 7 to 12 mm
- ASCO EM/WSEM are easily installed with a screw terminal coil
- Peak voltage suppression is standard for DC executions
- A range of solenoid valves can be supplied with the Ex e mb operator
ELECTRICAL CHARACTERISTICS & Connections
Standard voltages:
- DC (=) : 24V – 48V
- AC (~) : 24V-48V-115V-230V / 50 Hz 24V-48V-100V-115V-200V-230V / 50-60 Hz
- Features an internal and an external earthing connection
- The ASCO EM/WSEM operator can be rotated through 360° to select the best position for cable entry
asco em/wsem
AC (~) Solenoids
* AC (~): rectified coil construction
DC (=) Solenoids
ex e mb sOLENOID operator ORDERING INFORMATION
The valve supplied with the explosion proof operator will be identified with prefix EM/WSEM before the catalogue number. For example:
*Electrical interface
MV = EM
MW = WSEM
MT = EMET
MS = WSEMT
MN = EMT
MU = WSEMET
dimensions
TYPE EM/WSEM
Prefix “EM”/”WSEM” solenoids / Electrical interface MV/MW/MT/MS/MN/MU
Pull-type solenoid operator
Metal enclosure, epoxy coated or stainless steel
EN-IEC 60079-7, EN-IEC 60079-18 and EN-IEC 60079-31
II 2G Ex eb mb IIC Gb, II 2D Ex tb IIIC Db IP66/67
TYPE EM/WSEM
Prefix “EM”/”WSEM” solenoids / Electrical interface MV/MW/MT/MS/MN/MU
Push-type solenoid operator
Metal enclosure, epoxy coated or stainless steel
EN-IEC 60079-7, EN-IEC 60079-18 and EN-IEC 60079-31
II 2G Ex eb mb IIC Gb, II 2D Ex tb IIIC Db IP66/67
TYPE EM/WSEM
Prefix “EM”/”WSEM” solenoids / Electrical interface MV/MW/MT/MS/MN/MU
Pull-type solenoid operator
Metal enclosure, epoxy coated or stainless steel
EN-IEC 60079-7, EN-IEC 60079-18 and EN-IEC 60079-31
II 2G Ex eb mb IIC Gb, II 2D Ex tb IIIC Db IP66/67