H05Z1-K / H07Z1-K Industrial Cable

They are used as installation cables in distribution boards, switchboards and various appliances in closed areas when higher safety required in case of fire. They can be used on and…

Rated voltageH05Z1-K – 300/500V I H07Z1-K 450/750 V
ConductorElectrolytic annealed, class 5 stranded plain copper wires (tinned conductor on request)
InsulationHalogen-Free compound, TI7 type (EN 50363-7)
Operating temperature-30°C to +70°C
  • Quoted to your quantity
  • Documentation on request
  • International delivery

Product Overview

They are used as installation cables in distribution boards, switchboards and various appliances in closed areas when higher safety required in case of fire. They can be used on and under plaster or must be laid in pipes.

Technical Specifications

Rated voltageH05Z1-K – 300/500V I H07Z1-K 450/750 V
ConductorElectrolytic annealed, class 5 stranded plain copper wires (tinned conductor on request)
InsulationHalogen-Free compound, TI7 type (EN 50363-7)
Operating temperature-30°C to +70°C
ColorAll colors available
AC test voltage2,5 kV
Conductor short-circuit temp.160°C
Min. installation temp.-5°C
Min. bending radiusEN 50565-1 Tab. 3
Current carrying capacitiesVDE 0298-4 Tab. 5 & Tab. 11, IEC 60364-5-52 Tab. B52.2 & B52.4 & B52.10
Cross Section (mm²)Nominal Overall Diameter (mm)Approximate Weight (kg / km)Min.Bending Radius (free movement) (mm)Max. Resistance of Conductors at 20°C (ohm / km)
H05Z1-K
1×0,502,109839,0
H07Z1-K
1×1,52,90191213,3
1×2,53,5531147,98
1×44,0546164,95
1×64,6063183,3
1×106,10108241,91
1×167,10161281,21
1×259,20251460,780
1×3510,10340510,554
1×5012,00477600,386
1×7013,90680830,272
1×9515,90888950,206
1×12017,6011211060,161
1×15019,4013931160,129
1×18521,7016961300,106
1×24025,0022851500,0801
1×30027,8028251670,0641

Features

  • Flame retardant
  • Halogen-free
  • Low smoke

Certifications / Standards

  • EAC

Request Information About This Product

Tell us your quantity and requirements — we reply within one business day.

Related Products

3GKW M Industrial CableIndustrial Cables
Cables

3GKW M Industrial Cable

3GKW M Industrial Cable for industrial applications. Construction: Electrolytic tinned, class 5 stranded copper wires (Iec 60228); Halogen‐free. heat resistant. cross‐linked elastomeric special compound (Requirements based on type El 109…

0,6/1 kV · -40°.C … +120°.C

Have a product requirement?

Share your specifications and quantities. Our team will review your request and come back with sourcing options and a quotation.