33kV-36kV Enclosure – HV High Voltage Junction Box Zone 1 Hazardous Area

Abtech TFJB high voltage hazardous area electrical enclosures and junction boxes provide safe power distribution for 33-36kV systems up to 630sqmm cables – ATEX certified for Zone 1 and Zone 2 connection…

CategoryATEX Enclosures & Junction Boxes
  • Quoted to your quantity
  • Documentation on request
  • International delivery

Product Overview

Abtech TFJB high voltage hazardous area electrical enclosures and junction boxes provide safe power distribution for 33-36kV systems up to 630sqmm cables – ATEX certified for Zone 1 and Zone 2 connection of HV cables in hazardous area locations.

The 36kV enclosure has heavy duty machined hinges with lift off cover pad-lockable cover for easy installation and is DTS-01 deluge tested.

Abtech TFJB high voltage (HV) cable junction boxes are manufactured from 316L stainless steel and used primarily for jointing cables or as a connection box, the TFJB is capable of connecting three phases via bottom entry only and one conductor per phase in and out.

Hazardous Area Certification

  • ATEX EEx e (Zone 1 & Zone 2)
  • NEMA 4X (CSA, UL & FM) Class 1 Division 2
  • Deluge Tested To DTS-01

Zone 1 & 21, Gas and Dust / Class 1 Division 2

Type Of Explosion Protection – Ex tb

Apparatus Hazardous Area Coding – II 2 GD T4 Gb, Ex tb IIIC T135ºC Db

Temperature Rating

  • Standard: -20° to +40°C (-40° to 104°F)

High Voltage HV Enclosure Specification

  • Electrical Enclosure Type – High Voltage (HV)
  • Ingress Protection – IP66 to EN60529, Type 4X, DTS-01
  • Impact Resistance – >7Nm (tested above 10Nm)
  • Material – 2mm 316L Stainless Steel (EN 1.4404) enclosure with orbital finish, silicone gasket and captive 316 stainless steel fasteners, 3mm 316L (EN 1.4404) Stainless Steel gland plate
  • Ambient Temperature Rating – 20°C to +40°C
  • Suitable for 33-36kV
  • Maximum Terminations – 1 conductor per phase in & 1 conductor per phase out
  • Number of Gland Plates – 1 bottom side
  • Crimp Lugs – 6mm² to 630mm²
  • Earthing – Via Studs On Electrical Enclosure, Door & Cable Gland Plates
  • Mounting – Via 3mm thick external mounting straps, slotted upper strap for ease of installation

Enclosure Options

  • Abtech TFJB ACH HV Junction Box Enclosure – Anti-condensation heater
  • Abtech TFJB EP HV Junction Box Enclosure – Electro-polished
  • Abtech TFJB PS HV Junction Box Enclosure – Epoxy powder coated, smooth finish (RAL colour may be specified)
  • Abtech TFJB PT HV Junction Box Enclosure – Epoxy powder coated, Hammer Grey
  • Abtech TFJB MB HV Junction Box Enclosure – Mounting boss for eye bolts

Add the required suffix to the product reference. Example: Abtech TFJBPT = TFJB with hammer grey paint finish.

Technical Specifications

CategoryATEX Enclosures & Junction Boxes
Abtech Part RefWidth (mm)Height (mm)Depth (mm)Maximum Voltage (kV)Maximum Current (A)Power Rating at T4 (W)Ambient RangeWeight (kg)Hazardous Area Enclosure
TFJB 83 (0-2)800125040036312174-20ºC to +40ºC98Zone 1 & Zone 2

Request Information About This Product