Zone 1 & Zone 2 Hazardous Area ATEX – Abtech HVJB84

Abtech HVJB84 high voltage hazardous area electrical enclosures and junction boxes provide safe power distribution for 11kV systems up to 1000sqmm cables offering flexibility over the choice of cables, entries and cable…

CategoryOther Hazardous Area & Process Products
  • Quoted to your quantity
  • Documentation on request
  • International delivery

Product Overview

Abtech HVJB84 high voltage hazardous area electrical enclosures and junction boxes provide safe power distribution for 11kV systems up to 1000sqmm cables offering flexibility over the choice of cables, entries and cable terminations – ATEX certified for Zone 1 and Zone 2 locations and connection of HV cables in hazardous area locations.

Enclosure Application

Abtech HVJB84 high voltage enclosures are suitable for both industrial and hazardous areas.

Protection Degree IP66 or IP67.

Hazardous Area Certification

  • ATEX EEx e (Zone 1 & Zone 2) to BS EN 60079-7
  • NEMA 4X (CSA, UL & FM) Class 1 Division 2
  • Deluge Tested To DTS-01

Zone 1 & 21, Gas and Dust / Class 1 Div 2 / EAC (TR‐CU)

Type Of Explosion Protection – Ex e (Increased Safety), Ex tb (Dust Protected)

Apparatus Hazardous Area Coding – ATEX Ex e IIC T4 Gb, Ex tb IIIC T70°C Db / Ex e IIC T150°C Gb, Ex tb IIIC T110°C Db

Temperature Rating

  • Standard: -20° to +40°C (-4° to 104°F)
  • Option: -50° to +65°C (-58° to 149°F)

Junction Box Specification

* (x‐x) demotes the number of connectors per phase, 1st position = top, 2nd position = bottom. For example: HVJB73(2‐1) = 2 x conductors per phase top entry and 1 x conductor per phase bottom entry. ** Power rating is determined by ambient temp range: ‐20 to +400C / ‐50 to +550C respectively. The higher power rating can also be achieved if the enclosure is marked Ex e IIC T1500C Gb. *** For cables greater then 300mm2, it is advisable to use the HVJB8 size enclosure.

Technical Specifications

CategoryOther Hazardous Area & Process Products
Abtech Part RefWidth (mm) DimensionHeight (mm) DimensionDepth (mm)Power Rating (W) @ T4 (W)**Maximum Voltage (kV)Maximum Current (A)Maximum Conductor Size (sqmm)Hazardous Area Enclosure
HVJB784x‐x)800950300346/17311 kV9801000sqmm***Zone 1 & Zone 2