Zone 1 Fluorescent Hazardous Area Lighting ATEX Ex ed – Petrel 9 Series

Zone 1 Fluorescent Hazardous Area Lighting

CategoryATEX Lighting (Zone 1 & Zone 2)
  • Quoted to your quantity
  • Documentation on request
  • International delivery

Product Overview

Zone 1 Fluorescent Hazardous Area Lighting

ATEX Classification – Ex ed IIC Gb T5 or T4. Protection: IP 65

Petrel 9 Series are high output fluorescent lighting suitable for Zone 1 hazardous area lighting applications with a range of lamp wattages available from 36W to 116W. Available in both standard and emergency formats the Zone 1 ATEX light fittings have a light output up to 10,400 lumens.

Zone 1 fluorescent light fittings are manufactured from heavy duty aluminium extrusion with polycarbonate end caps and diffuser, the three hour duration emergency models are fitted with integral batteries and charger units.

Access to lamps is via a single point locking mechanism and mounting is enabled using “quick fit” T bolts in a channel for maximum flexibility. The modern design of this extremely rigid Zone 1 fluorescent luminaire allows unobtrusive use for both internal and external hazardous area lighting applications – Zone 2 fluorescent version also available.

Hazardous area & atex Approved

  • Certification and Hazardous Area Approval Certification Code: Standard: Ex ed IIC Gb T5 or T4. Emergency: Ex ed ib IIC Gb T5 or 4
  • Certification Number: SIRA 00ATEX 3071, IECEx SIR 08.0089
  • Certification standards: EN 60079, IEC 60079
  • Protection: IP65 to EN60529

Benefits & Options

  • Fast installation due to infinitely variable mounting position
  • Fluorescent will not leak due to multi-locking diffuser assembly
  • Safe working with internal isolation switch and diffuser retaining straps as standard
  • Pole mounting
  • Single point locking action
  • EOL lamp shut down
  • High light output for Zone 1 hazardous area locations
  • Integral battery with 3 hour duration on emergency light versions
  • Luminaire can be supplied without isolation switch
  • Through wiring (loop in, loop out) installation option (add TW reference suffix to versions)
  • Standard fluorescent versions: Petrel 9218/S2/HF (twin lamp 2x18W), 9236/S4/HF (twin lamp 2x36W), 9258/S5/HF (twin lamp 2x58W)
  • Emergency fluorescent versions: Petrel 9218/S2/EM (twin lamp 2x18W), 9236/S4/EM (twin lamp 2x36W), 9258/S5/EM (twin lamp 2x58W)
  • Lamp Sizes: S2 2x18W (760mm, 2ft), S4 2x36W (1365mm, 4ft), S5 2x58W (1665mm, 5ft)

where S = single lamp fitting and T = twin light fitting.

hazardous area zone 1 Single & Twin Light Fluorescent Fittings

Petrel Zone 1 fluorescent light fittings are available as twin lamps in 18 watts, 36 watts and 58 watts in standard and emergency variants – contact our team to discuss your hazardous area lighting requirements, we can provide lighting design layouts from the very simple to the extremely complex.

Zone 1

Technical Specifications

CategoryATEX Lighting (Zone 1 & Zone 2)
Part NumberPower ConsumptionLight Fitting DescriptionLight Fitting TypeZone 1 Light Fitting LengthLight OutputFixing CentresHazardous Area Classification
Petrel 9218/S2/HF2 (Twin) x 18 Watts2′ Twin T8 Exe LuminaireTwin Tube Fluorescent760mmUp to 3,300lm450mmZone 1 Ex de
Petrel 9236/S4/HF2 (Twin) x 36 Watts4′ Twin T8 Exe LuminaireTwin Tube Fluorescent1365mmUp to 6,700lm1055mmZone 1 Ex de
Petrel 9258/S5/HF2 (Twin) x 58 Watts5′ Twin T8 Exe LuminaireTwin Tube Fluorescent1665mmUp to 10,400lm1355mmZone 1 Ex de
Part NumberPower ConsumptionLight Fitting DescriptionLight Fitting TypeZone 1 Light Fitting LengthLight OutputFixing CentresHazardous Area Classification
Petrel 9218/S2/EM2 (Twin) x 18 Watts2′ Twin T8 Exe Luminaire (EM)Twin Tube Fluorescent760mmUp to 3,300lm450mmZone 1 Ex de
Petrel 9236/S4/EM2 (Twin) x 36 Watts4′ Twin T8 Exe Luminaire (EM)Twin Tube Fluorescent1365mmUp to 6,700lm1055mmZone 1 Ex de
Petrel 9258/S5/EM2 (Twin) x 58 Watts5′ Twin T8 Exe Luminaire (EM)Twin Tube Fluorescent1665mmUp to 10,400lm1355mmZone 1 Ex de
Supply Voltage230V 50/60Hz standard, 110V, 254V and 277V Optional on some 18W and 36W. 60Hz also optional. Suitable for central battery operation
Operating Temperature-20ºC to +55ºC standard supply subject to ambient temperature requirements
Control GearElectronic instant start ballast and integral charger inverter for emergency versions. EOL cut off. 3 hour operation with internal battery subject to ambient temperature
Lamp OptionsTwin 18W, 36W, 58W fluorescent fittings (Lamps not provided)
Cable Entries2 x M20 at each end (3 plugged as standard)
Terminals3 wire and earth. Cable size 4mm² max. Through wiring option available
Mounting Facility2 x M8 “Quick Fit” bolts available on variable centres for ease of monitoring
AccessTerminals accessed via quick release diffuser and reflector
MaterialAnodised corrosion resistant Aluminium and high impact polycarbonate diffuser and body mouldings. UV Resistant
FinishStandard colour – Aqua body mouldings natural aluminium for body centre section
DimensionsSize 2 760mm x 193mm, Size 4 1,365mm x 193mm, Size 5 1,665mm x 193mm
WeightStandard / Emergency Fluorescent Light Fittings 2x 18 Watt – 6.8kgs / 7.0kgs 2 x 36 Watt – 10.4kgs / 11.2kgs 2 x 58 Watt 12.0kgs / 13.0kgs
FeaturesExcellent light output for Zone 1 hazardous areas Heavy duty rigid construction Internal automatic isolation (may be omitted upon request) 110V, 254V and 277V available.