11kV Enclosure – Offshore Umbilical Cables Termination Box

Abtech SX125 high voltage hazardous area electrical enclosures and junction boxes provide safe power distribution to connect up to 24 power conductors for 11kV systems – ATEX certified for Zone 1 and…

CategoryATEX Enclosures & Junction Boxes
  • Quoted to your quantity
  • Documentation on request
  • International delivery

Product Overview

Abtech SX125 high voltage hazardous area electrical enclosures and junction boxes provide safe power distribution to connect up to 24 power conductors for 11kV systems – ATEX certified for Zone 1 and Zone 2 connection of HV cables in hazardous area locations and are based on the Abtech DPJB.

The 11kV enclosure is made from a marine grade stainless steel construction with an impact resistance of >10Nm.

Abtech SX125 high voltage (HV) cable junction boxes are manufactured from 316L stainless steel and provides a unique solution for the termination of offshore umbilical cables or onshore distribution systems.

A separate control compartment is used for terminating fibre optic or control cables. This allows the installer to work on optical fibres or control conductors without isolating HV supply

Hazardous Area Certification

  • ATEX EEx e (Zone 1 & Zone 2) to BS EN 60079-7
  • NEMA 4X (CSA, UL & FM) Class 1 Division 2

Zone 1 & 21, Gas and Dust / Class 1 Division 2

Type Of Explosion Protection – Ex e

Apparatus Hazardous Area Coding – ATEX II 2 GBm Ex e II T6

Temperature Rating

  • Standard: -20° to +40°C (-4° to 104°F)
  • Option: -50° to +65°C (-58° to 149°F)

High Voltage HV ENCLOSURE Specification

  • Electrical Enclosure Type – High Voltage (HV)
  • Ingress Protection – IP66 to EN60529, Type 4X
  • Material – 316L Stainless Steel (EN 1.4404) enclosure, silicone gasket and 316 stainless steel fasteners
  • Ambient Temperature Rating –20ºC to +55ºC
  • Maximum Number Of HV Cable Terminations – Refer to electrical enclosure rating table above
  • Dimensions – 1200mm (W) x 1250mm (H) x 300mm (D)
  • Max Terminations – 3 conductors per phase in & 3 conductors per phase out
  • Crimp Lugs – 16sqmm to 630sqmm
  • Earthing – Via Studs On Electrical Enclosure, Door & Cable Gland Plates
  • Mounting – Via external mounting feet

Enclosure Options

  • Abtech ACH – Anti-condensation heater
  • Abtech EP – Electro-polished
  • Abtech PS – Epoxy powder coated, smooth finish (RAL colour may be specified)
  • Abtech PT – Epoxy powder coated, Hammer Grey
  • Abtech 67 – IP67 ingress protected

Add the required suffix to the product reference. Example: SX125LR(1-3)ACH = SX125 right hand with 1 x conductor top, 3 x conductors bottom and anti-condensation heater

Technical Specifications

CategoryATEX Enclosures & Junction Boxes
Abtech Part RefControl Compartment OrientationMaximum Voltage (kV)Power Rating (W)Maximum Current (A)Maximum Fault Rating (kA)PhaseWeight (kg)
SX125LH(x-x)Left hand1150312503 or 3 + N132
SX125RH(x-x)Right hand1150312503 or 3 + N132