ATEX Detectors, Control & Distribution Units Zone 1 & Zone 2 Increased Safety Junction Box Ex e – Eaton MEDC JB10 & JB11

Eaton JB10 & JB11 are ATEX control & distribution junction boxes have been designed for use in hazardous and hostile environments in ATEX & IECEx Zone 1 and Zone 2 hazardous areas.

CategoryATEX Enclosures & Junction Boxes
  • Quoted to your quantity
  • Documentation on request
  • International delivery

Product Overview

Zone 1 & Zone 2

Eaton JB10 & JB11 are ATEX control & distribution junction boxes have been designed for use in hazardous and hostile environments in ATEX & IECEx Zone 1 and Zone 2 hazardous areas.

The robust design, coupled with corrosion-free GRP and high ingress protection, ensure a long life, low maintenance product.

Zone 1 & Zone 2

ATEX

Features

  • Zone 1 & 2 use.
  • UL listed for USA and Canada
    • Class I, Div 2, Groups A-D
    • Class I, Zone 1, AExe IIC T4 & T5
  • Exe II T4, T5 & T6.
  • ATEX approved Ex II 2G.
  • IECEx certified.
  • IP66, IP67, NEMA 4x & 6,.
  • Certified temperature: –50°C to +55°C*.
  • Corrosion free GRP.
  • Lightweight.
  • Robust.
  • Retained cover screws.
  • Optional gland continuity plate.
  • Optional internal conductive coating.
  • Variety of colours available.
  • Mixed rail mounted terminals.

*Depending on version.

Eaton MEDC JB10 & JB11 – Terminals

*275V if fitted with QB2 or QB4 cross connection links

All junction boxes will be supplied with an internal earth terminal appropriate to the terminals fitted.

If more than one internal earth terminal is required the maximum number of feed-through terminals must be reduced.

Eaton Medc JB10 & JB11 – Ordering Requirements

The following code is designed to help in selection of the correct Eaton hazardous area control & distribution unit with ATEX approval and certification. Build up the part number by inserting the code for each component into the appropriate box.

High Voltage Electrical Equipment

Technical Specifications

CategoryATEX Enclosures & Junction Boxes
Terminal type/sizeMax no. of terminalEach terminalMax voltage (V)Max current (A)T rating at +55°C(+40°C)
JB10JB11
SAK2.51016EK455015T4 (T6)
SAK4915EK455021T4
SAKK4813EK427528T4
SAK6N712EK455026T4
SAK1059EK1055037T4
SAK16–7EK1655047T4
AKZ2.51119AKE2.56015T4 (T6)
UK2.5N915USLKG5N55015T4 (T6)
UK5N714USLKG5N41821T4
UK10N49USLKG10N55037T4
UK16N37USLKG16N55047T4
MK6/666Internal earth stud418*26T5
BK44–Internal earth stud27521T5
Gland entriesMaximum no.of gland entries sides 1 & 3Maximum no.of gland entries sides 2 & 4Maximum no. gland entries (base)
With or without earth continuityWith earth continuityWithout earth continuityWith or without earth continuity
M162222
M202122
M25211N/A
M32111N/A
Gland entriesMaximum no.of gland entries per side with or without earth continuityMaximum no.of gland entries (base) with or without earth continuity
M1624
M2024
M252N/A
M321N/A
Hazardous Area Certifications
ATEXCert. no. Baseefa 12ATEX0039X Certified to: EN60079-0, EN60079-7 Ex II 2G, Ex e IIC T4/T5/T6 Gb
IECExCert. no. IECEx BAS 12.0029X Certified to: IEC 60079-0, IEC 60079-7 Ex e IIC T4/T5/T6 Gb
ULCert No. E237592 Class I, Div. 2, Groups A, B, C & D Class I, Zone 1, AEx e IIC, Ex e IIC
Specifications
MaterialGlass reinforced polyester (anti-static) stainless steel cover screws
FinishNatural black or painted to customer’s specification
Certified temp-50°C to +55°C
WeightJB10, 1.1 Kg. JB11,1.8 Kg
Ingress protectionIP66 and IP67
Gland continuityVia an internal BZP (bright zinc plated) steel plate

Request Information About This Product

Tell us your quantity and requirements — we reply within one business day.

Related Products

Have a product requirement?

Share your specifications and quantities. Our team will review your request and come back with sourcing options and a quotation.