ATEX Fan Heaters | Hazardous Area Zone 1 & Zone 2 | EXHEAT LFHEXHEAT LFH-15 ATEX Temporary Fan Heater | Zone 1 & Zone 2 Hazardous Areas
Product Code: LFH-15-440-T3-I

Offshore Portable Fan Heater | Zone 1 or Zone 2 (IIB) or Zone 21 or Zone 22 (IIC)
Offshore Portable Fan Heater | Zone 1 or Zone 2 (IIB) or Zone 21 or Zone 22 (IIC)
EXHEAT MFH “Bulldog” offshore portable flameproof fan heatersprovide safe portable, hazardous area certified heating and air warming for Zone 1 & Zone 2 (Flammable Gas) and Zone 21 & Zone 22 (Dust) hazardous areas and explosive atmospheres according to ATEX Directive in offshore hazardous areas.
The Bulldog offshore portable fan heater is the world’s first truly portable hazardous area fan assisted heater. The ATEX heaters feature a patented design (GB1614657.3) which utilises salt-water resistant materials to provide a portable heating solution for use in offshore environments where the potentially explosive atmosphere is classified as hazardous area Zone 1 or Zone 2 (IIB) or Zone 21 or Zone 22 (IIC).
Offshore “Bulldog” flameproof fan heaters are certified to meet ATEX equipment directive and are tough and durable with a casing made from steel reinforced polymer. The unit has adjustable feet allowing for the heater to be angled into position and the compact design means it can be easily stored or transported.
Typical heating applications include offshore containers, production platforms, paint curing and stores, spray booths, oil refineries and drilling and fabric maintenance.
The Offshore “Bulldog” can be used with or without ducting to provide a warm stream of air that can be felt up to five metres away, in ambient temperatures as low as -40°C or as high as +40°C.
The hazardous area portable fan heater comes ready to plug and play with the option of fitting a plug, or hard wiring to an isolator unit and can be optionally fitted with an additional safety device above and beyond the requirements of the certification.
lease download EXHEAT MFH hazardous area fan heaters O&M manual for full details on installation and maintenance procedures – this includes wiring diagrams, earth connection and pre installation inspection and checks.
Fan heater suitable for hazardous area Zone 1 & Zone 2 (IIB, IIC) gas groups.
* Voltage tolerance +0/-10%.
** Minimum SWA multicore cables required: 3Ph 380V–690V heaters require 4mm², 1Ph 220V-277V T4 heaters require 4mm², 110V-120V T4 & 220V-277V T3 heaters require 6mm², 110V-120V T3 heaters require 10mm².
*** ΔT (Delta T) refers to the air temperature difference at the inlet and outlet. For example, if the ambient is +6°C and the ΔT (temperature rise) is 15°C, then the outlet will be +21°C.
**** The maximum current includes the maximum motor inrush.
All values based on 25m cable lengths and an acceptable voltage drop of 4% at +40°C ambient.
Since 1985 as Leaders in ATEX Innovation we can facilitate succession planning for the replacement of obsolete, non-conformant and legacy equipment – we are the provider of innovative solutions to ensure ATEX and IECEx Compliance for Electrical, HVAC & Process Instrumentation systems in the explosive atmosphere industries.
| Category | ATEX Fans & Portable Ventilation |
|---|
| Hazardous Area Certifications | ATEXEx II 2 G D Ex hEx db eb IIB T3…T4 GbEx tb IIIC T200°C…T135°C Db IP65 | IECExEx db eb IIB T3…T4 GbEx tb IIIC T200°C…T135°C Db IP65 |
| CU TR (EAC) 1Ex db e IIB T3…T4 Gb XEx tb IIIC T200°C…T135°C Db X | CSA (USA/CAN) Approval Upcoming | |
| Dimensions | ||
| Measurements | Length – 475 x Width – 470 x Height – 530 mm | |
| Base Weight | 28 kg | |
| Main Materials | ||
| Casing | PA66 30% with EMI shielding | |
| Cabling | BS6883 certified, salt resistant and suitable for marine use | |
| Impeller | PA66 30% with EMI shielding with epoxy coated aluminium hub | |
| Elements | Finned Stainless Steel tubular elements | |
| Ex d Enclosure | Anodised extruded aluminium | |
| Ex e Enclosure | Stainless Steel | |
| Motor Housing | Epoxy coated aluminium | |
| Mounting | Adjustable feet at each corner allow for a stable standing on uneven surfaces. Wall mounting bracket option available (will require remote isolator for heater access/operation). Anti-static castors available. | |
| Rating | Up to 6kW | |
| Temp Class | Available in T3 and T4 temperature classes | |
| Voltage | Single-Phase: 110V to 277V Three-Phase: 380V to 690V, 50/60Hz | |
| EXHEAT Model | Voltage (*) | Phase (**) | Nominal Output (kW) | Air flow (m³/hr) | Air Temp. Delta (°C/°F) (***) | Max Current (A) (****) | ||
| 50 Hz | 60 Hz | 50 Hz | 60 Hz | |||||
| MFH – T3 Class | ||||||||
| MFH-5.5-220 | 220 | 1 | 5.5 | 1050 | 1260 | 16.2 / 29.2 | 13.5 / 24.3 | 25.6 |
| MFH-6-230 | 230 | 6 | 17.7 / 31.8 | 14.7 / 26.5 | 26.7 | |||
| MFH-5.5-240 | 240 | 5.5 | 16.2 / 29.2 | 13.5 / 24.3 | 23.5 | |||
| MFH-6-254 | 254 | 6 | 17.7 / 31.8 | 14.7 / 26.5 | 24.2 | |||
| MFH-6-277 | 277 | 6 | 17.7 / 31.8 | 14.7 / 26.5 | 22.3 | |||
| MFH-5.5-380 | 380 | 3 | 5.5 | 16.2 / 29.2 | 13.5 / 24.3 | 9.0 | ||
| MFH-6-400 | 400 | 6 | 17.7 / 31.8 | 14.7 / 26.5 | 9.3 | |||
| MFH-5.5-415 | 415 | 5.5 | 16.2 / 29.2 | 13.5 / 24.3 | 8.3 | |||
| MFH-6-440 | 440 | 6 | 17.7 / 31.8 | 14.7 / 26.5 | 8.5 | |||
| MFH-6-480 | 480 | 6 | 17.7 / 31.8 | 14.7 / 26.5 | 7.8 | |||
| MFH-6-600 | 600 | 6 | 17.7 / 31.8 | 14.7 / 26.5 | 6.4 | |||
| MFH-6-690 | 690 | 6 | 17.7 / 31.8 | 14.7 / 26.5 | 5.6 | |||
| MFH – T4 Class | ||||||||
| MFH-2.5-110 | 110 | 1 | 2.5 | 1050 | 1260 | 7.4 / 13.3 | 23.3 | |
| MFH-3-120 | 120 | 3 | 8.8 / 15.9 | 25.6 | ||||
| MFH-2.75-220 | 220 | 2.75 | 8.1 / 14.6 | 13.1 | ||||
| MFH-3-230 | 230 | 3 | 8.8 / 15.9 | 13.6 | ||||
| MFH-2.75-240 | 240 | 2.75 | 8.1 / 14.6 | 12.1 | ||||
| MFH-3-254 | 254 | 3 | 8.8 / 15.9 | 12.4 | ||||
| MFH-3-277 | 277 | 3 | 8.8 / 15.9 | 11.4 | ||||
| MFH-2.75-380 | 380 | 3 | 2.75 | 8.1 / 14.6 | 4.8 | |||
| MFH-3-400 | 400 | 3 | 8.8 / 15.9 | 4.9 | ||||
| MFH-2.75-415 | 415 | 2.75 | 8.1 / 14.6 | 4.4 | ||||
| MFH-3-440 | 440 | 3 | 8.8 / 15.9 | 4.6 | ||||
| MFH-3-480 | 480 | 3 | 8.8 / 15.9 | 4.3 | ||||
| MFH-3.7-600 | 600 | 3.7 | 10.9 / 19.6 | 4.2 | ||||
| MFH-3.7-690 | 690 | 3.7 | 10.9 / 19.6 | 3.7 | ||||
Tell us your quantity and requirements — we reply within one business day.
ATEX Fan Heaters | Hazardous Area Zone 1 & Zone 2 | EXHEAT LFHProduct Code: LFH-15-440-T3-I
ATEX Fan Heaters | Hazardous Area Zone 1 & Zone 2 | EXHEAT LFHEXHEAT XLFH-C fixed fan heater incorporates superior efficiency with ease of use offering a heating solution for hazardous areas (ATEX, IECEX and CU TR EAC) where the potentially explosive atmosphere is classified…
ATEX Fan Heaters | Hazardous Area Zone 1 & Zone 2 | EXHEAT LFHEXHEAT XLFH – T2 fixed fan heater incorporates superior efficiency with ease of use offering a heating solution for hazardous areas (ATEX, IECEX and CU TR EAC) where the potentially explosive atmosphere…
Share your specifications and quantities. Our team will review your request and come back with sourcing options and a quotation.