Other Hazardous Area & Process ProductsMarechal 596M6 | 60D Angle Adapter Metal Blue
Product Code: 596M6

Eaton MEDC HD1 are ATEX heat detectors that have been designed for use in ATEX & IECEx Zone 1 and Zone 2 hazardous areas. These hazardous are heat detectors are suitable for…
Eaton MEDC HD1 are ATEX heat detectors that have been designed for use in ATEX & IECEx Zone 1 and Zone 2 hazardous areas. These hazardous are heat detectors are suitable for fire alarm and/or suppression systems in offshore and onshore applications including paint spray booths, flammable material stores, turbine rooms, extract ductwork and other hazardous areas throughout the oil & gas, petrochemical and process industries.
Comprising a Fenwal rate-compensated detector with all-stainless steel external construction, mounted to either a type SM87 marine grade alloy enclosure (Ex d version) or JB10 corrosion-free GRP enclosure (Ex ia, Ex em/UL versions). The contact in the ATEX heat detector closes at alarm temperature.
ATEX
*Model dependent.
To select appropriate temperature settings, choose detector at 100ºF (38ºC) above maximum ambient temperature.
The following code is designed to help in selection of the correct Eaton hazardous area heat detector with ATEX & IECEx approval and certification. Build up the part number by inserting the code for each component into the appropriate box.
High Voltage Electrical Equipment
| Category | Other Hazardous Area & Process Products |
|---|
| Temperature Setting | Tolerance | Colour Code Text on Probe | ||
| (ºF) | (ºC) | (ºF) | (ºC) | |
| 140 | 60 | +7/-8 | ±4 | Black |
| 160 | 71 | +7/-8 | ±4 | Black |
| 190 | 88 | +7/-8 | ±4 | White |
| 210 | 99 | +7/-8 | ±4 | White |
| 225 | 107 | +7/-8 | ±4 | White |
| 275 | 135 | ±10 | ±6 | Blue |
| 325 | 163 | ±10 | ±6 | Red |
| 360 | 182 | ±10 | ±6 | Red |
| 450 | 232 | ±15 | ±8 | Green |
| 500 | 260 | ±15 | ±8 | Orange |
| 600 | 316 | ±20 | ±11 | Orange |
| 725 | 385 | ±25 | ±14 | Orange |
| Hazardous Area Specification | |
| ATEX EEx d IIB | Cert. no. Baseefa03ATEX0447. Certified to: EN50014, EN50018, EN50281-1-1. Ex II 2 GD, EEx d IIB T6 (T3 @ 125ºC). |
| ATEX Ex d IIC | Cert. no. Baseefa08ATEX0320. Certified to: EN60079-0, EN60079-1, EN61241-0, EN61241-1. Ex II 2 GD, Ex d IIC T6, Ex tD A21 T85ºC (-20ºC to + 55ºC). |
| ATEX EEx em | Cert. no. Baseefa03ATEX0428. Certified to: EN50014, EN50019, EN50028. Ex II 2G, EEx em II T6 (-20ºC to + 55ºC) |
| ATEX Ex ia | Cert. no. Baseefa03ATEX0427. Certified to: EN60079-0, EN60079-11. Ex II 1G, Ex ia IIC T6 Ga (-55ºC to + 55ºC). (T4 with diodes/resistors). |
| IECEx Ex ia | Ex II 1G, Ex ia IIC T6 Ga (-55ºC to + 55ºC). (T4 with diodes/resistors). IECEx Ex ia: Cert. no. BAS 13.0010. Certified to: IEC60079-0, IEC60079-11 Ex ia IIC T6 Ga (-55ºC to + 55ºC). (T4 with diodes/resistors) |
| UL | Listing no. E252920 – versions up to 450ºF. Listing no. E254077 – versions from 600ºF to 725ºF. UL for USA and Canada, listed to Class 1, Div 2. Groups A – D |
| CUTR | 1Ex d IIB T3/T6. 2Ex de IIC T4/T6. 0Ex ia IIC T4/T6 Russian Fire Approved. |
| CQST | Certified Ex ia. |
| Inmetro | Certified EEx d, EEx ia & EEx em |
| ABS | American Bureau of Shipping type approval for HD1BBD & HD1B1 only |
| SIL | SIL2 certified. Cert no. Sira FSP 12007/02 |
| Technical Specification | |
| Material | Detector: stainless steel. Enclosures: Exd – LM25 marine grade alloy. Exia/Exem/UL – GRP (anti-static). Stainless steel cover screws. Optional Guard: 316 stainless steel. |
| Finish | Detector: Sand blasted. Enclosures: Exia/Exem/UL – Natural black or painted to customer’s specification. Exd painted to customers specification |
| Certified Temp | -20ºC to 55ºC (T6) Exem, UL, Exd IIC, CQST Exd IIB. -20ºC to 55ºC (T6) -20ºC to 125ºC (T3) Exd IIB (Not CQST). -55ºC to 55ºC (T6) Exia. |
| Weight | Exd, 2kg. Exia/Exem/UL, 1.1kg |
| Ingress Protection | IP66 & IP67 |
| Operation | The detector contact is normally open and CLOSES at alarm temperature. |
| Contact Rating | Ex d, EEx em, UL: 125V a.c.-5A, 125V d.c.-0.5A, 48V d.c.-1A, 24V d.c.-2A. Ex ia: 30V – 300mA |
| Entries | 2 x M20 ISO (ATEX/Exd/Exe/Exi versions). 2 x ½” NPT via adaptors (UL version) |
| Terminals | 6 x 4sqmm (BK6). |
| Resistor | Series & EOL resistor (maximum total 2) minimum value (each) 470Ω |
| Diodes | Up to 2 off available in Exd IIB and Exia versions |
| Labels | Optional stainless steel tag and duty labels |
Tell us your quantity and requirements — we reply within one business day.
Other Hazardous Area & Process ProductsProduct Code: 596M6
Other Hazardous Area & Process ProductsApplication – Hazardous Area
Other Hazardous Area & Process ProductsApplication – Hazardous Area
Share your specifications and quantities. Our team will review your request and come back with sourcing options and a quotation.