ATEX Loudspeakers Zone 1 & Zone 2 Weatherproof Ex d(e) – Eaton DB4B Hazardous Area Loudspeakers Up To 25 Watts

Eaton DB4B are ATEX loudspeakers with a high power explosion proof speaker, introduced as a replacement for the DB4 with improved intelligibility and acoustic performance.

CategoryATEX Sounders & Beacons
  • Quoted to your quantity
  • Documentation on request
  • International delivery

Product Overview

ATEX Loudspeakers Zone 1 & Zone 2

Eaton DB4B are ATEX loudspeakers with a high power explosion proof speaker, introduced as a replacement for the DB4 with improved intelligibility and acoustic performance.

Certified for use in a wide range of temperatures (from -55ºC to +70ºC) the Ex enclosure is manufactured from GRP with a rugged thermoplastic flare providing a corrosion free and aesthetically pleasing product suitable for use in ATEX & IECEx Zone 1 and Zone 2 hazardous areas.

The frequency response of the hazardous area loudspeakers ensures that critical voice messages and general alarm tones are highly intelligible. The specific SPL figure for sensitivity is 1W @ 1m is 110dB whilst at 1m the 25W unit produces 124dB, the 15W unit 122dB and the 8W unit 119dB.

Options include DC blocking capacitors for monitored systems, resettable fuses for compliance with marine regulations and a swivel bracket that gives the installer greater flexibility when positioning the unit. The short flare option is a worthy addition to the range offering a high SPL and wide dispersion angle in a compact unit.

ATEX Loudspeakers Zone 1 & Zone 2

ATEX

Features

  • Ex d / Ex de IIC / IIIC T4/T5/T6.
  • ATEX certified.
  • IECEx certified.
  • cULus certified
  • INMETRO certified
  • TR CU certified
  • SIL2 certified
  • DNV certified
  • CCOE certified
  • Certified temperature -55ºC to +70ºC.*
  • IP66 & IP67.
  • Optional Ex e terminal chamber.
  • 124dB at 25W, 1m.*
  • 8W, 15W & 25W versions.
  • Power tappings, via integral transformer.
  • Frequency response 350Hz – 8kHz.
  • Ex enclosure – Glass reinforced polyester.
  • Flare – High impact thermoplastic polyester.
  • Stainless steel mounting bracket and cover screws.
  • Mounting bracket has ratchet facility as standard.
  • Optional swivel bracket available

Transformer: Used by combining the rated power tappings below:

Eaton DB4B – Ordering Requirements

The following code is designed to help in selection of the correct Eaton hazardous area loudspeakers with ATEX approval and certification. Build up the part number by inserting the code for each component into the appropriate box.

Eaton MEDC

Eaton MEDC have developed ATEX products designed for harsh and hazardous area conditions and where there is a risk of explosion due to the presence of flammable atmospheres both onshore and offshore – since 1975 MEDC have been designers and manufacturers of alarm, signal, control and communications equipment.

Complete range of LV-HV Cable Joints, Terminations, Cleats & Glands are available to support installation of power, control and instrumentation cables up to 33kV – includes Cold Shrink for use in hazardous areas to provide electrical insulation and cable protection.

Thermon | EXHEAT | Abtech | Marechal Electric | 3M Electrical

Technical Specifications

CategoryATEX Sounders & Beacons
TappingsPower
8W15W25W
1:28.015.025.0
2:34.07.512.5
3:42.05.06.0
1:31.54.04.0
2:40.72.02.0
1:40.40.81.0
Values in dB @ 1m (Unsmoothed, peak values)8W15W25W
LongShortLongShortLongShort
IIC Gas1.0kHz115112117114120117
IIC Gas1.4kHz119116122119124122
IIC & IIIC Gas & Dust1.0kHz110107112109115112
IIC & IIIC Gas & Dust1.4kHz114111117114119116
Hazardous Area Certification
ATEX Ex d GasCert. no. Baseefa13ATEX0229X. Certified to: EN60079-0,1 Ex II 2G, Ex d IIC T4/T5/T6 Gb
ATEX Ex d Gas & DustCert. no. Baseefa13ATEX0231X. Certified to: EN60079-0,1,31 Ex II 2GD, Ex d IIC T4/T5/T6 Gb, Ex tb IIIC T135°C/T100°C/T85°C Db, IP66
ATEX Ex de GasCert. no. Baseefa13ATEX0232X. Certified to: EN60079-0,1,7 Ex II 2G, Ex de IIC T4/T5/T6 Gb
ATEX Ex de Gas & DustCert. no. Baseefa13ATEX0233X. Certified to: EN60079-0,1,7,31 Ex II 2GD, Ex de IIC T4/T5/T6 Gb, Ex tb IIIC T135°C/T100°C/T85°C Db, IP66
IECEx Ex d GCert. no. IECEx BAS 13.0112X. Certified to: IEC60079-0,1 Ex d IIC T4/T5/T6 Gb
IECEx Ex d Gas & DustCert. no. IECEx BAS 13.0113X. Certified to: IEC60079-0,1,31 Ex d IIC T4/T5/T6 Gb, Ex tb IIIC T135°C/T100°C/T85°C Db, IP66
IECEx Ex de GasCert. no. IECEx BAS 13.0114X. Certified to: IEC60079-0,1,7 Ex de IIC T4/T5/T6 Gb
IECEx Ex de Gas & DustCert. no. IECEx BAS 13.0115X. Certified to: EN60079-0,1,7,31 Ex de IIC T4/T5/T6 Gb, Ex tb IIIC T135°C/T100°C/T85°C Db, IP66
UL Haz Locs
UL Ord LocsUL certified for USA and Canada, listing no. S8847
TR CU Ex d Gas1Ex d IIC T4/T5/T6 Gb
TR CU Ex d Gas & Dust1Ex d IIC T4/T5/T6 Gb, Ex tb IIIC T135°C/T100°C/T85°C Db
TR CU Ex de Gas1Ex de IIC T4/T5/T6 Gb
TR CU Ex de Gas & Dust1Ex de IIC T4/T5/T6 Gb, Ex tb IIIC T135°C/T100°C/T85°C Db
Russian Fire ApprovalAll TR CU certified units are Russian Fire Approved
CQST Ex d GasEx d IIC T4/T5/T6 Gb
CQST Ex d Gas & DustEx d IIC T4/T5/T6 Gb, Ex tb IIIC T135°C/T100°C/T85°C Db
INMETRO Ex d GasEx d IIC T4/T5/T6 Gb
INMETRO Ex d Gas & DustEx d IIC T4/T5/T6 Gb, Ex tb IIIC T135°C/T100°C/T85°C Db, IP66
INMETRO Ex de GasEx de IIC T4/T5/T6 Gb
INMETRO Ex de Gas & DustEx de IIC T4/T5/T6 Gb, Ex tb IIIC T135°C/T100°C/T85°C Db, IP66
SILSIL 2 certification to IEC61508. Cert number 20151119-4786827453
Type approvalDNV (IEC60945)
Specifications
MaterialEx enclosure – flame retardant, UV stable, glass reinforced polyester Flare – flame retardant, high impact, UV stable, thermoplastic polyester (UV stability tested to ISO 4892 part 3) Hardware – bracket, fixings and captive cover screws in 316 stainless steel
Fire retardancyBody – glass reinforced polyester. V0 flammability rating Outer flare – thermoplastic polyester. V0 flammability rating
FinishBody – natural black. Flare – natural black, natural red or painted as specified (Black short flare painted black)
Rated power
Frequency rangeFrequency response 350Hz to 8kHz 8W and 15W units are available for use @ 200Hz
WeightEx d/UL – 5.0kg, Ex de – 5.8kg. Based on long flare with transformer
Ingress protectionIP66 & IP67, NEMA 4X & 6. (IPx7 & NEMA 6 on terminal chamber only)
Earth continuityOptional for Ex de version. Not available on Ex d unit
EntriesUp to 2 x M20 or 1/2” NPT. Blanking plug available
TerminalsEx d – 8 x 2.5sqmm (4sqmm solid conductor)/ 12AWG. Ex de – 8 x 4.0sqmm
Mounting arrangementStainless steel bracket with ratchet facility, optional swivel bracket available
LabelsOptional duty and tag labels available
Dispersion angleLong flare (short in brackets), -6dB, 1kHz = 140º (240º), 4kHz = 40º (50º)
Driver impedance8Ω
SPL 1W/1m (sensitivity)IIC long flare, 1kHz – 106dB, 1.4kHz – 110dB
Certified temperatureProtection type Minimum Temp Maximum Temperature All units 8W unit 15W unit 25W unit Ex d/UL -55°C +70°C +65°C +55°C Ex de -50°C
Protection typeMinimum TempMaximum Temperature
All units8W unit15W unit25W unit
Ex d/UL-55°C+70°C+65°C+55°C
Ex de-50°C