Crowcon Detective+ | Portable Flammable Gas Detector ATEX Certified

Crowcon Detective+ | ATEX Zone 1 & Zone 2 Hazardous Areas

CategoryGas Detection
  • Quoted to your quantity
  • Documentation on request
  • International delivery

Product Overview

Portable Gas Detectors

Crowcon Detective+ | ATEX Zone 1 & Zone 2 Hazardous Areas

Fixed Gas Detection & Portable Gas Safety | Industrial Locations & Hazardous Area Zones

The Crowcon Detective+ portable gas detector is an area monitoring gas detector designed for group protection and can be used to provide a virtual fence line and in areas for the presence of selected flammable gases and triggers an audible and visual alarm if set levels are reached.

Crowcon Detective+ gas detection equipment is rugged and interconnectable with up to 25 Detective+ units up to 100m apart from each other to indicate an alarm sensed by any one unit.

The Detective+ units can be connected via cables or via the Detective Wireless module.

The Detective+ gas detector can now be fitted with infra-red (IR) sensors providing either CO₂ detection or allowing higher levels of flammable gas monitoring. IR sensors also provide immunity to the poisoning effects which standard flammable gas sensors can suffer from.

C-Test bump solution with configuration update keeps the Crowcon detectors correctly configured to ensure the product is consistently up-to-date without the need for a service or technician team.

The Detective+ portable flammable gas detector is also water and dust resistant to IP65.

Key Features

Should you require a quotation, check stock or technical customer service about the Crowcon Detective+ please do not hesitate to contact our team.

  • Simple Operation – The Crowcon Detective+ is available with infrared sensors, has a clear display and has an optional built in pump providing a fast response with clear information for gas identification
  • Rugged Design – The Detective+ has a rugged tripod design that has a folding or flexible legs and meets IP65 specifications
  • Audible Alarms – 25 Detective+ units can be linked together up to 100m from nearby units. A visual red alarm with an audible and visible confidence blip. The units sending the alarm flash faster with multiple beacons to ensure fast reactions to gas hazards

Crowcon Detective+ Bump Testing & Calibration

Routine bump testing is recommended for the range of Crowcon portable gas detectors prior to each use. Bump testing is a brief application of a gas to the sensor to invoke a prescribed reaction, ensuring the gas detector reacts as expected.

Bump testing provides a quick, easy and direct method of verifying gas detectors are performing as required and takes a lot less time than ‘zeroing’ the device.

The bump test is widely accepted as a suitable method of testing gas detection equipment.

Crowcon Detective+ Gas Detector – Product Specifications

* Toxic and oxygen sensors are not rated for continuous operation at high temperatures.

** Toxic and oxygen sensors RH specifications vary, consult Crowcon for specific operating humidities.

Gases Detected & Ranges

* One biased sensor per Detective+.

+ Reactive gas, care required during sampling, contact Crowcon for details.

Crowcon Detective+ Gas Detector Infrared Sensors

Several gas detection sensors are available for use with the Crowcon Detective+ gas detector.

Also see the range of Crowcon Fixed Gas Detectors

Crowcon Detective+ Hazardous Area ATEX Certified Gas Detector

Hazardous Area Classification

Europe: ATEX II 2G Ex ib d IIC T4 (Tamb -20°C to + 50°C)
International: Ex ib d IIC T4 (Tamb -20°C to + 50°C)

The hazardous area gas detector is Category 2G suitable for use in Zone 1 and Zone 2 with flammable gases and vapours – this includes apparatus groups IIA, IIB and IIC and with temperature classes Tl, T2, T3 and T4 3. The Crowcon Detective+ is only certified for use in ambient temperatures in the range -20°C to +50°C and should not be used outside this range.

Gas Detection In High Voltage Substations, SWITCHGEAR & Hazardous Area Battery Rooms

See how Crowcon F-Gas Detector is used in the electrical utility industry to provide safe gas detection of SF6 in high voltage substations and gas insulated switchgear.

Technical Specifications

CategoryGas Detection
Size640 x 455 x 455mm (25.2 x 17.9 x 17.9ins)
Weight7.5kg (19oz)
Visible AlarmsThree large, top mounted red LED clusters and a single red LED on control panel. Alarm mode: LED clusters flash in quick succession. LED clusters of linked Detectives repeating the alarm, flash slower than LED lights on those Detectives sensing the hazard. Normal working: Slow flashing green LED. Battery low: Rapid flashing green LED
Audible AlarmsWailing, omni-direction siren, 104 dBA at 1m
DisplayHigh contrast LCD with back light. Values and units for up to 4 gases displayed simultaneously at current, TWA or peak levels, low battery, real time and elapsed calibration and configuration data also displayed.
BatteryStandard 6V, 7.2Ah, sealed lead acid battery pack Optional 6V, 12Ah high capacity pack
Battery LifeUp to 36 hours with 7.2Ah battery Up to 60 hours with optional 12A battery
Typical Response TimesMethane 20s, oxygen 10s, typical toxic gas 20s, IR 20s
Expected Sensor LifeFlammable 5 years, toxic 3 years, oxygen 2 years minimum, IR>5 years
Humidity15–95% RH non-condensing**
Ingress ProtectionIP65
Operating Temperature Range-20ºC to +50ºC (-4ºF to 122ºF)*
Shelf life6-month shelf life prior to activation. Shown on box label
Sensor RangeH2S: 0-100ppm. CO: 0-300ppmO2: 0-30% vol
ApprovalsEurope: ATEX II 2G Ex ib d IIC T4 (Tamb -20°C to + 50°C) International: Ex ib d IIC T4 (Tamb -20°C to + 50°C)
StandardsEN 50014: 1997 + A1 & A2; EN 50018: 2000: EN 55011: 1998; DD ENV 50204:1999:EN 61010- 1: 2001; EN50020: 2002: IEC 60079-0: 2000, IEC 60079-1: 2003: IEC 60079-11: 1999
EMCEN 50270, FCC CFR47 Part 15, Directive 2014/30/EU EN50270
PC InterfaceVia RS232 lead. Portables PC software can be used to set alarms, clock, datalogging interval and password, manages datalogging giving graphical display of instrument log file and allows to export to spreadsheet
CalibrationQuick calibration using internal menu command, Portables PC
AccessoriesBaffle plate, interconnecting leads, RS232 communications lead, Detective NET
SamplingInternal electric sampling pump option, manual aspiration
Linked DetectivesWith cable connection, up to 12 units can be linked to provide perimeter or area monitoring With Detective NET , up to 25 units can be linked to provide perimeter or area monitoring
Detectable GasGas Detector RangeGas Detector Alarm
Flammable Gas0-100 LEL20% LEL
Oxygen O20-25%19% & 23%
Hydrogen Sulphide H2S0-50 ppm10 ppm
Carbon Monoxide CO0-500 ppm35 ppm
Sulphur Dioxide SO20-10 ppm2 ppm
Chlorine CL20-5 ppm0.5 ppm
Nitrogen Dioxide NO20-10 ppm2 ppm
Phosphine PH30-5 ppm0.5 ppm
Ammonia HN30-50 ppm25 ppm
Ammonia NH30-1000 ppmN/A
Hydrogen (Non flammable levels)0-2000 ppmN/A
Hydrogen Cyanide HCN0-25 ppm10 ppm
Hydrogen Chloride HCL */+0-10 ppm5 ppm
Chlorine Dioxide CIO2 +0-1 ppm0.1 ppm
Hydrogen Fluoride HF +0-10 ppm1 ppm
Ethylene Oxide C2H4O *0-10 ppm5 ppm
Volatile Organic */+0-100 ppmN/A
Detectable GasGas Detector RangeGas Detector Alarm
Flammable Gas0-100% LEL20& LEL
Flammable Gas0-100% v/vNone
Available for methane, propane, butane or ethylene
Carbon Dioxide CO20-5% v/v0.5 and 1.5% v/v

Request Information About This Product

Tell us your quantity and requirements — we reply within one business day.

Related Products

Have a product requirement?

Share your specifications and quantities. Our team will review your request and come back with sourcing options and a quotation.