Product Overview
Crowcon TXgard-IS+
Single Gas & Multi-gas Detectors | Fixed Point Gas Detection & Portable Gas Safety Applications | Industrial Locations & Hazardous Area Zones
Crowcon TXgard-IS+ | ATEX Zone 0, Zone 1 & Zone 2
TXgard-IS+ manufactured by Crowcon, is a fixed gas detector that is ATEX certified for use in Zone 0, Zone 1 or Zone 2 hazardous areas. The Crowcon TXgard-IS+ is intrinsically safe and is UL and cUL certified for gas detection in Division 1 or 2 hazardous areas.
Crowcon TXgard-IS+ has a wide selection of sensors including a number of catalytic beads for a wide selection of flammable gases and vapours as well as electrochemical sensors for toxic gases and oxygen.
The Crowcon TXgard-IS+ gas detector is easy to calibrate, maintenance and operation are simple and the long life sensors keep disruption to site to a minimum.
Crowcon TXgard-IS+ has an ingress protection to IP65 as a standard.
Key Features
- Robust Construction – Crowcon TXgard-IS+ is constructed from tough carbon loaded nylon and an IP65 rating as standard.
- Flexible Options – The TXgard-IS+ is available in 2 or 3 wire formats with a 40-20mA current sink or source. Relays for alarm and fault are also options.
- Low Ownership Costs – Sensors are long life with simple part replacement making the gas detector easy to operate and maintain.
- Calibration – The TXgard-IS+ can be calibrated with ease and boasts local display and buttons so the junction box doesn’t need to be opened. Non-intrusive one man calibration can be performed locally without the need for hot work permits.
- Range of Sensors – This gas detector can be tailored to meet the user’s needs with a choice of catalytic beads for a wide selection of flammable gases and vapours and an extensive range of electrochemical sensors for toxic gases and oxygen.
Crowcon TXgard-IS+
Bump Testing And Calibration
Routine bump testing is recommended for the range of Crowcon fixed gas detectors prior to each use. Bump testing is a brief application of a gas to the sensor to invoke a prescribed reaction, ensuring the gas detector reacts as expected.
Bump testing provides a quick, easy and direct method of verifying gas detectors are performing as required and takes a lot less time than ‘zeroing’ the device.
The bump test is widely accepted as a suitable method of testing gas detection equipment.
Crowcon TXgard-IS+ Fixed Gas Detector | Gases And Ranges Detected
TXgard-IS+ detects an extensive range of toxic, flammable and oxygen gases:
Crowcon TXgard-IS+ Hazardous Area ATEX Certified Gas Detector
Hazardous Area Classification
Ex II 1 G Ex ia IIC T4 Ga
UL Class I, groups A, B, C and D
Crowcon TXgard-IS+ is an ATEX certified gas detector for use in Zone 0,1 or 2 hazardous areas – also UL and cUL certified for use in Division 1 or 2 hazardous areas.
Visit hazardous area gas detectors for explosion and flameproof gas monitoring and detection instruments with certification for potentially explosive atmospheres, including Zone 1 and Zone 2 (according to ATEX and IECEx) and Class/Division categories (according to North American standards).