Crowcon Xsafe Gas Detector

Single Gas & Multi-gas Detectors | Fixed Point Gas Detection & Portable Gas Safety Applications | Industrial Locations & Hazardous Area Zones

CategoryGas Detection
  • Quoted to your quantity
  • Documentation on request
  • International delivery

Product Overview

Fixed Gas Detectors

Single Gas & Multi-gas Detectors | Fixed Point Gas Detection & Portable Gas Safety Applications | Industrial Locations & Hazardous Area Zones

Crowcon Xsafe | Gas Detection for Non-Hazardous Areas

The Crowcon Xsafe fixed gas detector is a robust flammable gas detector suitable for use in non-hazardous areas.

Part of the Xgard family of gas detection equipment, the Xsafe gas detector has a tough alloy housing, offers a standard design and reliability without the extra cost of certified electronics.

Crowcon Xsafe gas detector is a non-certified low cost catalytic bead type detector which has 3-wire 4-20mA or mV bridge output.

Crowcon Xgard Gas Detector – Product Range

The diagram below illustrates how to determine which gas detector best suits the requirements of the end user.

CROWCON Xsafe GAS DETECTOR – PRODUCT SPECIFICATIONS

*3/4 ” cable entry only available on aluminium junction boxes.

Visit hazardous area gas detectors for explosion and flameproof gas monitoring and detection instruments with certification for potentially explosive atmospheres, including Zone 1 and Zone 2 (according to ATEX and IECEx) and Class/Division categories (according to North American standards).

Technical Specifications

CategoryGas Detection
Size156 x 166 x 111mm (6.1 x 6.5 x 4.3 inches)
Weight1kg (2.2lbs)
Enclosure materialAluminium
Ingress protectionIP65
Cable entries1 x M20, 1/2 “NPT or 3/4 NPT* on right-side
Terminations0.5 to 2.5mm2
Sensor typeCatalytic bead
Operating temperaturemV: -40 to +80°C (-40 to 176°F) mA: -40 to +55°C (-40 to 131°F)
Storage-25°C to +65°C (-13°F to +149°F)
Humidity10 to 95% RH
Repeatability Zero drift<2% FSD (Typical) <2% FSD per Month (Typical)
Response timeT90 <15s (Typical)
Operating voltagemA: 10-30V dc mV: 2.0V dc
Power requirementsmA: 50mA at 24V dc 1.2W mV: 300mA (Typical)
Electrical outputmA: 3- wire 4-20mA (current sink or source) mV: 3- wire mV bridge Typical signal: 12-15mV/ %LEL CH4
ApprovalsNot certified for use in hazardous environments
EMC complianceEN 50270 FCC Part 15 ICES- 003