ATEX Lights | Hazardous Area Lighting | Zone 1 & Zone 2 ATEX LightingEx de Explosion Proof Floodlights For Hazardous Areas | Technor FL-50HA
Floodlights for Zone 1, Zone 21, Zone 2, Zone 22

Fluorescent Lighting for Zone 1, Zone 21, Zone 2, Zone 22 Hazardous Area Lighting Applications
Fluorescent Lighting for Zone 1, Zone 21, Zone 2, Zone 22 Hazardous Area Lighting Applications
Technor’s EV HID is a wellglass Ex d lighting fixture suitable for hazardous area lighting and offersoffers Ex-e IIC mode of protection and are suitable for indoor and outdoor hazardous areas of industrial plants where narrow or wide beam lighting is required.
Technor EV HID wellglass lighting is classified to international hazardous area classifications with ATEX, IECEx and TRCU certification, with ingress protection IP66 and an operational ambient temperature range of -52°C to +60°C.
Technor EV HID wellglass lighting fixtures are designed to house built-in control gears for high intensity discharge lamps, mercury vapour, metal halide and high pressure sodium; light source can be driven where required by way of suitable reflectors. The body of the EV HID wellglass is constructed from aluminium with a low content of copper, providing corrosion resistance and a lamp compartment made from tempered glass.
EVde version, with integrated Ex e junction box, allows end users and contractors the possibility to save one junction box, two cable glands and a minimum of 30 minutes of labour during installation process. This version is supplied complete with an adjustable AISI304 stainless steel mounting bracket suitable for ceiling, wall and suspension installation.
(NA) High Pressure Sodium
* With micro-switch
** In case of maximum ambient temperature reach +60°C, temperature class changes into T4/T135°C (ordering code to be required)
In case of maximum ambient temperature reach +40°C, temperature class changes into T6/T85°C (ordering code to be required)
(HG) Mercury Vapour
*In case of maximum ambient temperature reaches +40°C and except for light/bulb oriented on top (topward), temperature class changes into T4 (ordering code to be required)
Notes:
– Below -20°C, the mercury vapour light can be used, providing they are switched on 24 hours a day
– Mercury vapour light bulb is not included (banned by the European Community)
(IM) Metal Halide
* In case of maximum ambient temperature reaches +40°C and except for light/bulb oriented on top (topward), temperature class changes into T4 (ordering code to be required).
Below -20°c, the metal halide light can be used, providing they are switched on 24 hours a day
EVCC version, without integrated Ex e junction box, allows standard ceiling installation.
(NA) High Pressure Sodium
*In case of maximum ambient temperature reaches +55°C and except for light/bulb oriented on top (topward), temperature class changes into T4 (ordering code to be required)
** Lamp with built-in glow discharge ignitor
(HG) Mercury Vapour
*In case of maximum ambient temperature reaches +40°C and except for light/bulb oriented on top (topward), temperature class changes into T4 (ordering code to be required)
Notes:
– Below -20°C, the mercury vapour light can be used, providing they are switched on 24 hours a day
– Mercury vapour light bulb is not included (banned by the European Community)
(IM) Metal Halide
* In case of maximum ambient temperature reaches +40°C and except for light/bulb oriented on top (topward), temperature class changes into T4 (ordering code to be required).
Below -20°c, the metal halide light can be used, providing they are switched on 24 hours a day
EVA version, without integrated Ex e junction box, allows standard suspension installation by conduit system and pastoral pole.
(NA) High Pressure Sodium
*In case of maximum ambient temperature reaches +55°C and except for light/bulb oriented on top (topward), temperature class changes into T4 (ordering code to be required)
** Lamp with built-in glow discharge ignitor
(HG) Mercury Vapour
*In case of maximum ambient temperature reaches +40°C and except for light/bulb oriented on top (topward), temperature class changes into T4 (ordering code to be required)
Notes:
– Below -20°C, the mercury vapour light can be used, providing they are switched on 24 hours a day
– Mercury vapour light bulb is not included (banned by the European Community)
(IM) Metal Halide
* In case of maximum ambient temperature reaches +40°C and except for light/bulb oriented on top (topward), temperature class changes into T4 (ordering code to be required).
Below -20°c, the metal halide light can be used, providing they are switched on 24 hours a day
ATEX
IECEx
under IEC Ex directive, junction boxes and enclosures are suitable for IIC group of gases/dusts only
Approvals
Certified 01ATEX0019X, IECEx INE 15.0031X, TR CU (marking upon request, ordering code to be required).
| Category | ATEX Lighting (Zone 1 & Zone 2) |
|---|
| Material | Aluminium with low content of copper |
| IP rating | IP66 |
| Ambient temperature range | -52°C to +60°C |
| Approvals | INERIS 01ATEX0019X, IECEx INE 15.0031X, CoC TR CU 012/2011 (marking upon request, ordering code to be required) |
| Gaskets | O-ring made of Nitrile Rubber (NBR) |
| Surface treatment | Green colour polyurethane painting cycle RAL6003 (other colour available upon request) |
| Entries | N° 2 entries M25x1,5 (EVde and EVCC version) / N° 1 entry M25x1,5 (EVA version) / (plugs and cable glands excluded) |
| Hardware and screws | AISI304 Stainless steel external hardware and screws |
| Lamps | Included |
| Ballast | Electromechanical ballast |
| Rated Operation Voltage (UE) | 230 V (standard) / 220 V, 240 V, 250 V, 277 V (upon request) |
| Frequency | 50 Hz (standard) / 60 Hz (upon request) |
| Accessories available upon request | Protection guard / Reflector / Pole mounting kit (EVde version) |
| Operating Principles | HOT INSTANT RESTRIKE solution available via twin-arc lamp assuring immediate hot instant restrike ignition with flux that will reach 80% of the nominal lamp flux in about 3 minutes. HOT INSTANT RESTRIKE solution also available via INSTANT RESTRIKE BALLAST, assuring immediate hot instant restrike ignition with 80% of the lamp nominal flux in 7 seconds. (for high pressure sodium version) |
| Technor Part Number | Code | Lamp (W) | Weight (Kg) | Temperature Class | Dimensions (mm) | Drawing | |||
| A | B | C | D | ||||||
| EVDE-2/NA-B 50 | A041121F01114 | 50** | 6.00 | T3* | 680 | 466 | 214 | 162 | TAB A-1 |
| EVDE-3/NA-B 50 | A041131F01114 | 50 | 6.00 | T3* | 686 | 472 | 214 | 194 | TAB A-1 |
| EVDE-2/NA-B 70 | A041121H01114 | 70** | 6.00 | T3* | 680 | 466 | 214 | 162 | TAB A-1 |
| EVDE-3/NA-B 70 | A041131H01114 | 70 | 7.40 | T3* | 686 | 472 | 214 | 194 | TAB A-1 |
| EVDE-4/NA-B 100 | A041141101114 | 100 | 7.60 | T3* | 748 | 533 | 214 | 220 | TAB A-1 |
| EVDE-4/NA-B 150 | A041141151114 | 150 | 8.40 | T3* | 748 | 533 | 214 | 220 | TAB A-1 |
| EVDE-4/NA-B 250 | A041141251114 | 250 | 15.00 | T3 | 890 | 676 | 214 | 220 | TAB A-1 |
| EVDE-5/NA-B 250 | A041151251114 | 250 | 16.70 | T3* | 970 | 756 | 214 | 281 | TAB A-2 |
| EVDE-5/NA-B 400 | A041151401114 | 400 | 18.00 | T3 | 970 | 756 | 214 | 281 | TAB A-2 |
| Technor Part Number | Code | Lamp (W) | Weight (Kg) | Temperature Class | Dimensions (mm) | Drawing | |||
| A | B | C | D | ||||||
| EVDE-2/HG-B 50 | A042121F01114 | 50 | 6.00 | T3* | 680 | 466 | 214 | 162 | TAB A-1 |
| EVDE-2/HG-B 80 | A042121I01114 | 80 | 6.00 | T3* | 680 | 472 | 214 | 194 | TAB A-1 |
| EVDE-3/HG-B 125 | A0421311B0113 | 125 | 7.40 | T3 | 686 | 472 | 214 | 194 | TAB A-1 |
| EVDE-5/HG-B 250 | A042151250114 | 250 | 15.70 | T3 | 970 | 756 | 214 | 281 | TAB A-2 |
| EVDE-5/HG-B 400 | A042151400114 | 400 | 16.50 | T3 | 970 | 756 | 214 | 281 | TAB A-2 |
| Technor Part Number | Code | Lamp (W) | Weight (Kg) | Temperature Class | Dimensions (mm) | Drawing | |||
| A | B | C | D | ||||||
| EVDE-3/IM-B 70 | A043131H01114 | 70 | 6.00 | T3* | 680 | 472 | 214 | 194 | TAB A-1 |
| EVDE-4/IM-B 100 | A043141101114 | 100 | 6.00 | T3* | 748 | 533 | 214 | 220 | TAB A-1 |
| EVDE-4/IM-B 150 | A043141151114 | 150 | 7.40 | T3* | 890 | 676 | 214 | 220 | TAB A-1 |
| EVDE-4/IM-B 250 | A043141251114 | 250 | 14.80 | T3 | 890 | 676 | 214 | 220 | TAB A-2 |
| EVDE-5/IM-B 250 | A043151251114 | 250 | 15.70 | T3* | 890 | 676 | 214 | 220 | TAB A-2 |
| EVDE-E/IM-B 400 | A043151401114 | 400 | 16.50 | T3 | 970 | 756 | 214 | 281 | TAB A-2 |
| Technor Part Number | Code | Lamp (W) | Weight (Kg) | Temperature Class | Dimensions (mm) | Drawing | |
| A | B | ||||||
| EVCC-2/NA-B 50 | A041221F01114 | 50** | 5.50 | T3* | 406 | 162 | TAB B |
| EVCC-3/NA-B 50 | A041231F01114 | 50 | 6.90 | T3* | 411 | 194 | TAB B |
| EVCC-2/NA-B 70 | A041221H01114 | 70** | 5.50 | T3* | 406 | 162 | TAB B |
| EVCC-3/NA-B 70 | A041231H01114 | 70 | 6.90 | T3* | 411 | 194 | TAB B |
| EVCC-4/NA-B 100 | A041241101114 | 100 | 7.10 | T3* | 474 | 220 | TAB B |
| EVCC-4/NA-B 150 | A041241151114 | 150 | 7.90 | T3* | 474 | 220 | TAB B |
| Technor Part Number | Code | Lamp (W) | Weight (Kg) | Temperature Class | Dimensions (mm) | Drawing | |
| A | B | ||||||
| EVCC-2/HG-B 50 | A042221F01114 | 50 | 5.50 | T3* | 406 | 162 | TAB B |
| EVCC-2/HG-B 80 | A042221I01114 | 80 | 5.50 | T3* | 406 | 162 | TAB B |
| EVCC-3/HG-B 125 | A0422311B0113 | 125 | 6.90 | T3 | 411 | 194 | TAB B |
| Technor Part Number | Code | Lamp (W) | Weight (Kg) | Temperature Class | Dimensions (mm) | Drawing | |
| A | B | ||||||
| EVCC-3/IM-B 70 | A043231H01114 | 70 | 6.90 | T3* | 411 | 194 | TAB B |
| EVCC-4/IM-B 100 | A043241101114 | 100 | 7.10 | T3* | 474 | 220 | TAB B |
| EVCC-4/IM-B 150 | A043241151114 | 150 | 7.90 | T3* | 474 | 220 | TAB B |
| Technor Part Number | Code | Lamp (W) | Weight (Kg) | Temperature Class | Dimensions (mm) | Drawing | |
| A | B | ||||||
| EVA-2/NA-B 50 | A041321F01114 | 50** | 5.50 | T3* | 400 | 162 | TAB C |
| EVA-3/NA-B 50 | A041331F01114 | 50 | 6.90 | T3* | 404 | 194 | TAB C |
| EVA-2/NA-B 70 | A041321H01114 | 70** | 5.50 | T3* | 400 | 162 | TAB C |
| EVA-3/NA-B 70 | A041331H01114 | 70 | 6.90 | T3* | 404 | 194 | TAB C |
| EVA-4/NA-B 100 | A041341101114 | 100 | 7.10 | T3* | 467 | 220 | TAB C |
| EVA-4/NA-B 150 | A041341151114 | 150 | 7.90 | T3* | 467 | 220 | TAB C |
| Technor Part Number | Code | Lamp (W) | Weight (Kg) | Temperature Class | Dimensions (mm) | Drawing | |
| A | B | ||||||
| EVA-2/HG-B 50 | A042321F01114 | 50 | 5.50 | T3* | 400 | 162 | TAB C |
| EVA-2/HG-B 80 | A042321I01114 | 80 | 5.50 | T3* | 400 | 162 | TAB C |
| EVA-3/HG-B 125 | A0423311B0113 | 125 | 6.90 | T3 | 404 | 194 | TAB C |
| Technor Part Number | Code | Lamp (W) | Weight (Kg) | Temperature Class | Dimensions (mm) | Drawing | |
| A | B | ||||||
| EVA-3/IM-B 70 | A043331H01114 | 70 | 6.90 | T3* | 404 | 194 | TAB C |
| EVA-4/IM-B 100 | A043341101114 | 100 | 7.10 | T3* | 467 | 220 | TAB C |
| EVA-4/IM-B 150 | A043341151114 | 150 | 7.90 | T3* | 467 | 220 | TAB C |
Tell us your quantity and requirements — we reply within one business day.
ATEX Lights | Hazardous Area Lighting | Zone 1 & Zone 2 ATEX LightingFloodlights for Zone 1, Zone 21, Zone 2, Zone 22
ATEX Lights | Hazardous Area Lighting | Zone 1 & Zone 2 ATEX LightingFloodlights for Zone 1, Zone 21, Zone 2, Zone 22
ATEX Lights | Hazardous Area Lighting | Zone 1 & Zone 2 ATEX LightingFloodlights for Zone 1, Zone 21, Zone 2, Zone 22
Share your specifications and quantities. Our team will review your request and come back with sourcing options and a quotation.