ATEX Fan Heaters | Hazardous Area Zone 1 & Zone 2 | EXHEAT LFHEXHEAT LFH-15 ATEX Temporary Fan Heater | Zone 1 & Zone 2 Hazardous Areas
Product Code: LFH-15-440-T3-I

Product Code: LFH – T4
Product Code: LFH – T4
REQUEST A QUOTE
CALL US: +44 (0)191 410 4292
EXHEAT’s LFH-T4 ATEX Temporary Fan Heater is designed to provide dependable heat in challenging Zone 1, Zone 2, Zone 21 and Zone 22 Hazardous Area environments. Certified to the new EN 80079-36 and EN 80079-37 standards for constructional safety, the EXHEAT LFH – T4 electric fan heater offers up to 20kW of thermal power.
SEE TECHNICAL SPECIFICATIONS
GO TO DOWNLOADS
Product Overview
Technical Specifications
Key Benefits
Applications
Certifications
EXHEAT LFH – T4 Fixed fan heater incorporates superior efficiency with ease of use offering a heating solution for hazardous areas (ATEX, IECEX and CU TR EAC) where the potentially explosive atmosphere is classified as Zone 1 & Zone 2 according to ATEX Directive.
The LFH Fan Heater, manufactured by EXHEAT, comes ready to ‘plug and play’, with the option of fitting a plug, or hard wiring to an isolator unit. Integrating a stainless steel robust casing for added toughness and durability, the EXHEAT LFH electric heater has been developed to function in ambient temperatures of -40°C to +40°C.
Certified to the new EN 80079-36 and EN 80079-37 standards for constructional safety, the EXHEAT LFH – T4 electric fan heater offers up to 20kW of thermal power.
The electric heater uses a framework allowing for multiple mounting options on floors, walls, and even ceilings.
Contact our trusted experts – place an order or find out more about the EXHEAT XLFH-T4 for your operations.
Contact Our Experts
✔ Delivers a powerful and reliable 14.5kW heating output for hazardous area use
✔ Certified for Zone 1 & Zone 2 gas and Zone 21 & Zone 22 dust environments
✔ Achieves up to a 38°C temperature rise using patented heating technology
✔ Provides constant full-output heating for consistent temporary heat delivery
✔ Operates reliably in extreme ambient temperatures down to –40°C
✔ RTD monitoring protects the elements and maintains correct T-Class ratings
✔ Long flying lead available for flexibility and convenience
✔ Fully ductable on inlet and outlet for precise heat placement
✔ Stainless steel construction for long-term durability in harsh environments
✔ Anti-static castors and lifting handles allow easy on-site movement
✔ Local isolation switch provides straightforward, safe operation
✔ Optional power cables and plugs available on request
✔ Low-maintenance design ideal for demanding temporary heating tasks
✔ Aircraft servicing and aerospace maintenance environments
✔ Offshore containers, drilling rigs and production platforms
✔ Oil refineries, petrochemical plants and hazardous processing areas
✔ Comfort heating in controlled or temporary industrial spaces
✔ Curing and drying of paints, coatings and composite repairs
✔ Frost protection for sensitive equipment and work environments
✔ Paint stores, spray booths and controlled finishing rooms
✔ Pipe wrapping, composite repair works and habitat pressurisation
✔ Shipboard areas including deck houses, pump stations and engine rooms
✔ Temporary enclosures and maintenance habitats requiring safe heating
✔ Any Zone 1 & Zone 2 hazardous area requiring reliable temporary heat
The LFH-15 is designed to meet stringent global safety requirements, with full ATEX, IECEx and CU TR (EAC) certification for use in explosive gas (IIB) and dust (IIIC) atmospheres. A bespoke low-temperature protection system allows operation down to –40°C, while an integrated RTD sensor monitors heating element temperature to maintain the assigned T-Class Rating and safeguard against overheating. With superior build quality, high thermal performance and proven safety, the EXHEAT XLFH-T4 stands out as the leading ATEX temporary fan heater for reliable, high-output heating in hazardous industrial environments.
II 2 G D
Ex db eb h IIB+H2 T2…T4 Gb
Ex tb IIIC T300°C…T135°C Db IP65
Ex db eb h IIB+H2 T2…T4 Gb
Ex tb IIIC T300°C…T135°C Db IP65
1Ex db eb IIB+H2 T3…T4 Gb X
Ex tb IIIC T200°C T135°C Db X
| Category | ATEX Fans & Portable Ventilation |
|---|
| Model | Duty (kW) | Volts | Max Current (A) | Air Delta T (°C/°F) ³ |
| LFH – T4 XLFH-14.5-440-T4 XLFH-14.5-440-T4 (Temporary) | 9 | 440V | 13 | 26 / 47 |
| 8 | 415V | 12 | 23 / 41 | |
| 7.5 | 400V | 12 | 22 / 40 | |
| 6.5 | 380V | 10 | 19 / 34 | |
| 7.5 | 230V (3Ph) | 12 | 22 / 40 | |
| Up to 9 | Up to 690V | Based on Voltage | Up to 26 / 47 |
| Component | Material |
| Casing | Stainless steel |
| Impeller | PA66 30% glass and steel filled blades and epoxy coated aluminium hub |
| Elements | Finned stainless steel tubular elements |
| Ex d Enclosure | Anodised aluminium |
| Ex e Enclosure | Stainless steel |
| Motor Housing | Epoxy coated aluminium |
| Model | Specification | 50Hz | 60Hz |
| LFH – T4 XLFH-14.5-440-T4 XLFH-14.5-440-T4 (Temporary) | Approx Air Velocity at Outlet (m/s) | 6.0 | 6.3 |
| Approx Volumetric Flow Rate (m³/hr) | 2120 | 2240 | |
| Fan Speed (min⁻¹) | 1380 | 1460 | |
| Motor Rating (kW) | 1.1 | 1.1 | |
| Sound Pressure (dBA) | 78 | 80 |
Tell us your quantity and requirements — we reply within one business day.
ATEX Fan Heaters | Hazardous Area Zone 1 & Zone 2 | EXHEAT LFHProduct Code: LFH-15-440-T3-I
ATEX Fan Heaters | Hazardous Area Zone 1 & Zone 2 | EXHEAT LFHEXHEAT XLFH-C fixed fan heater incorporates superior efficiency with ease of use offering a heating solution for hazardous areas (ATEX, IECEX and CU TR EAC) where the potentially explosive atmosphere is classified…
ATEX Fan Heaters | Hazardous Area Zone 1 & Zone 2 | EXHEAT LFHEXHEAT XLFH – T2 fixed fan heater incorporates superior efficiency with ease of use offering a heating solution for hazardous areas (ATEX, IECEX and CU TR EAC) where the potentially explosive atmosphere…
Share your specifications and quantities. Our team will review your request and come back with sourcing options and a quotation.