Hazardous Area Zone 1 & Zone 2 ATEX | Remote Control Units & Emergency Shutdown Stations

EXHEAT remote control units and emergency shutdown stations are designed to offer a local interface for equipment in the field, controlled by a remote source. These units can be manufactured for use…

CategoryATEX Electric & Process Heaters
  • Quoted to your quantity
  • Documentation on request
  • International delivery

Product Overview

Remote Control Units

EXHEAT remote control units and emergency shutdown stations are designed to offer a local interface for equipment in the field, controlled by a remote source. These units can be manufactured for use in both hazardous and non-hazardous areas, having the control facility for on and emergency stop, with indications for on and fault status.

All products are supplied with full wiring schematics and hazardous area certification as required. Suitable cable gland kits can also be provided to ensure a one-stop cost effective solution. All units are provided with our standard warranty and are built and tested in our ISO 9001 certified UK factory, ensuring that EXHEAT’s unrivalled high standards are incorporated throughout all of our products.

Hazardous Area Classification

  • ATEX / IECEx / GOST: Zone 1, 2, 21, 22
  • NEC 505 Class 1: Zone 1, 2
  • NEC 500: Class I Div 2; Class II Div 1, 2; Class III Div 1, 2

Ex d & Ex de flameproof concepts

Ex d – “Flameproof Enclosure” Protection EN 50018 where the potentially explosive or incendive components are contained within an enclosure into which the flammable atmosphere can enter but which will contain any resultant explosion and prevent its transmission outside the enclosure into the hazardous area. Ex de solutions combine the benefits of both the increased safety Ex e and flameproof Ex d types of protection.

hazardous area equipment protection levels

  • G=gas, D=dust, M=mining
  • *in presence of explosive atmospheres

hazardous areas & T CLASSes

Temperature class is defined by ignition temperature – the lowest temperature at which a vapour will be ignited.

Flashpoint is the lowest temperature at which a liquid generates sufficient vapour to support ignition – this vapour could be ignited by temperature or energy (i.e. a spark).

  • there is no connection between ignition energy and ignition temperature

EXHEat

Technical Specifications

CategoryATEX Electric & Process Heaters
ATEX 94/9/ECATEX / IECEx Ex II 2 G II2 G Ex db IIC II2 D Ex tb IIIC (T85°C — T150°C) II2 G Ex ed II T6 II2 D Ex tD A21 T85°C
IECExEx db IIB T6 Ex tb IIIC (T85°C — T150°C) Ex ed II T6 Ex tD A21 T85°C
InmetroEx db IIB T6 Ex tb IIIC (T85°C — T150°C) Ex ed II T6 Ex tD A21 T85°C
GOST-R (RTR-N)/K1 Ex d IIB T6 Ex tD A21 (T85°C — T150°C) Ex ed Gb IIC T6 Ex t IIIC Db Ex tD A21 T85°C
NEC505 USLClass 1, Zone 1 Ex db IIB Zone 21 Ex tb IIIC (T85°C — T150°C)
NEC505 CNLEx d IIB Class II, Group E, F, G
GaGbGcDaDbDcMaMb
Zone 0Zone 1Zone 2Zone 20Zone 21Zone 22EnergisedDe-energised*
Temperature ClassMax. Surface Temperature
T1<450ºC – eg Acetone/Methane Gas Group IIA
T2<300ºC – eg Butane/Propane Gas Group IIA
T3<200ºC – eg Heptane/Ethylene Gas Group IIA
T4<135ºC – eg Ethyl Methyl Ether/Hydrogen Gas Group IIB
T5<100ºC
T6<85ºC

Request Information About This Product

Tell us your quantity and requirements — we reply within one business day.

Related Products

Have a product requirement?

Share your specifications and quantities. Our team will review your request and come back with sourcing options and a quotation.